Users Guide

Cpu1minUsage (89%)
01:01:29: %STKUNIT7-M:CP %SYSADM-5-TASK_CPU_THRESHOLD:
1min cpu utilization of management-unit has exceeded the threshold. Top
three processes are sysdlp (79.79%), system (7.60%), sysd (1.01%)
!.!.!.!!.01:01:34: %STKUNIT7-M:CP %SYSADM-5-CPU_THRESHOLD:
Overall cpu usage of stack-unit 10 is above threshold.
Cpu1minUsage (90%)
01:01:34: %STKUNIT7-M:CP %SYSADM-5-TASK_CPU_THRESHOLD:
1min cpu utilization of stack-unit 10 has exceeded the threshold.
Top three processes are dla (88.75%), KP (2.50%), frrpaRecv (0.00%)
!.!.!.!.!01:01:40: %STKUNIT7-M:CP %SYSADM-5-CPU_THRESHOLD:
Overall cpu usage of stack-unit 9 is above threshold.
Cpu1minUsage (96%)
01:01:40: %STKUNIT7-M:CP %SYSADM-5-TASK_CPU_THRESHOLD:
1min cpu utilization of stack-unit 9 has exceeded the threshold.
Top three processes are dla (94.83%), KP (2.17%), frrpaRecv (0.00%)
!.01:01:40: %STKUNIT7-M:CP %SYSADM-5-CPU_THRESHOLD:
Overall cpu usage of stack-unit 11 is above threshold.
Cpu1minUsage (96%)
01:01:40: %STKUNIT7-M:CP %SYSADM-5-TASK_CPU_THRESHOLD:
1min cpu utilization of stack-unit 11 has exceeded the threshold.
Top three processes are dla (94.58%), KP (2.25%), frrpaRecv (0.00%)
!.!.!.!.!01:01:45: %STKUNIT7-M:CP %SYSADM-5-CPU_THRESHOLD:
Overall cpu usage of stack-unit 0 is above threshold. Cpu1minUsage (91%)
01:01:46: %STKUNIT7-M:CP %SYSADM-5-TASK_CPU_THRESHOLD:
1min cpu utilization of stack-unit 0 has exceeded the threshold.
Top three processes are dla (89.75%), KP (2.67%), frrpaRecv (0.00%)
!.!.!.!.!!.!.!.!.!!.!.!.!.!.!!.!.!.!.!!.!.!.!.!.!.!!.!.!.!.!.
!!.!.!.!.!.!!.!.!.!.!.!.!!.!.!.!.!!.!.!.!.!!.!.!.!.!.!.!!.!.!.
!.!.!!.!.!.!.!.!.!!.!.!.!.!.!!.!.!.!.!!.!.!.!.!.!
Bootflash image upgrade for all completed successfully.
upgrade system (stack unit)
Upgrade the Dell Networking OS image on one or all stack units in an S5000 stack from the master switch.
S5000
Syntax
upgrade system {flash://file-path | ftp://file-path | scp://file-path |
tftp://file-path | usbflash://file-path} | stack-unit {stack-unitid | all}
{A: | B:}}
Parameters
boot Enter the keyword system to change the Dell Networking OS image.
flash: After the keyword flash:, enter the location of the source file in the internal flash
in the format: //file-pathname or press Enter to launch a prompt sequence.
ftp: After the keyword ftp:, enter the location of the source file in the format: //
userid:password@host-ipaddress/filepathname or press Enter to
launch a prompt sequence.
scp: After the keyword scp:, enter the location of the source file in the format: //
userid:password@host-ip-address/file-pathname or press Enter to
launch a prompt sequence.
tftp: After the keyword tftp:, enter the location of the source file in the format: //
host-ipaddress/file-pathname or press Enter to launch a prompt
sequence.
usbflash: After the keyword usbflash:, enter the location of the source file in the external
flash in the format: //file-path or press Enter to launch a prompt sequence.
file-path
Enter the path and filename to be used to upgrade the Dell Networking OS image.
1568 Stacking Commands