Reference Guide
Simple Network Management Protocol (SNMP) | 833
Enable a subset of Dell Networking enterprise specific SNMP traps using one of the listed command
options in Table 47-2 with the command
snmp-server enable traps. Note that the envmon option enables
all environment traps including those that are enabled with the envmon supply, envmon temperature,
and envmon fan options.
Table 47-2. Dell Networking Enterprise-specific SNMP Traps
Command Option Trap
envmon CARD_SHUTDOWN: %sStack unit %d down - %s
CARD_DOWN: %sStack unit %d down - %s
LINECARDUP: %sStack unit %d is up
CARD_MISMATCH: Mismatch: stack unit %d is type %s - type %s required.
RPM_STATE: RPM1 is in Active State
RPM_STATE: RPM0 is in Standby State
RPM_DOWN: RPM 0 down - hard reset
RPM_DOWN: RPM 0 down - card removed
HOT_FAILOVER: RPM Failover Completed
SFM_DISCOVERY: Found SFM 1
SFM_REMOVE: Removed SFM 1
MAJOR_SFM: Major alarm: Switch fabric down
MAJOR_SFM_CLR: Major alarm cleared: Switch fabric up
MINOR_SFM: MInor alarm: No working standby SFM
MINOR_SFM_CLR: Minor alarm cleared: Working standby SFM present
TASK SUSPENDED: SUSPENDED - svce:%d - inst:%d - task:%s
RPM0-P:CP %CHMGR-2-CARD_PARITY_ERR
ABNORMAL_TASK_TERMINATION: CRASH - task:%s %s
CPU_THRESHOLD: Cpu %s usage above threshold. Cpu5SecUsage (%d)
CPU_THRESHOLD_CLR: Cpu %s usage drops below threshold. Cpu5SecUsage (%d)
MEM_THRESHOLD: Memory %s usage above threshold. MemUsage (%d)
MEM_THRESHOLD_CLR: Memory %s usage drops below threshold. MemUsage (%d)
DETECT_STN_MOVE: Station Move threshold exceeded for Mac %s in vlan %d
CAM-UTILIZATION: Enable SNMP envmon CAM utilization traps.