Reference Guide
sFlow | 823
Figure 46-4. Command Example: show running-config interface
Show sFlow on a Stack Unit
Use the following command to view sFlow statistics on a specified stack unit:
Figure 46-5 is a sample output from the
show sflow stack-unit command:
Figure 46-5. Command Example: show sflow stack-unit
Specifying Collectors
The sflow collector command allows identification of sFlow Collectors to which sFlow datagrams are
forwarded. The user can specify up to two sFlow collectors. If two Collectors are specified, the samples are
sent to both.
Polling Intervals
The sflow polling-interval command configures the polling interval for an interface in the maximum
number of seconds between successive samples of counters to be sent to the collector. This command
changes the global default counter polling (20 seconds) interval. You can configure an interface to use a
different polling interval.
Command Syntax Command Mode Purpose
show sflow stack-unit unit-number EXEC Display sFlow configuration information and statistics on
the specified interface.
Dell#show running-config interface tengigabitethernet 1/16
!
interface TenGigabitEthernet 1/16
no ip address
mtu 9252
ip mtu 9234
switchport
sflow enable
sflow sample-rate 8192
no shutdown
Dell#show sflow stack-unit 1
Stack-Unit 1
Samples rcvd from h/w :0
Total UDP packets exported :0
UDP packets exported via RPM :0
UDP packets dropped :0
Dell#