Reference Guide

822 | sFlow
www.dell.com | support.dell.com
Show sFlow Globally
Use the following command to view sFlow statistics:
Figure 46-2 is a sample output from the
show sflow command:
Figure 46-2. Command Example: show sflow
Show sFlow on an Interface
Use the following command to view sFlow information on a specific interface:
Figure 46-3 is a sample output from the
show sflow interface command.
Figure 46-3. Command Example: show sflow interface
The configuration, shown in Figure 46-2, is also displayed in the running configuration (Figure 46-4):
Command Syntax Command Mode Purpose
show sflow EXEC Display sFlow configuration information and statistics.
Command Syntax Command Mode Purpose
show sflow interface
interface-name
EXEC Display sFlow configuration information and statistics on a
specific interface.
Dell#show sflow
sFlow services are enabled
Global default sampling rate: 32768
Global default counter polling interval: 20
1 collectors configured
Collector IP addr: 133.33.33.53, Agent IP addr: 133.33.33.116, UDP port: 6343
77 UDP packets exported
0 UDP packets dropped
165 sFlow samples collected
69 sFlow samples dropped due to sub-sampling
Indicates sFlow is globally enabled
Dell#show sflow interface tengigabitethernet 1/16
Te 1/16
Configured sampling rate :8192
Actual sampling rate :8192
Sub-sampling rate :2
Counter polling interval :15
Samples rcvd from h/w :33
Samples dropped for sub-sampling :6