Reference Guide

Port Monitoring | 693
Figure 37-2. Number of Monitoring Ports on the S5000
In Figure 37-3, 0/25 and 0/26 belong to Port-pipe 1. This port-pipe again has the same restriction of only
four destination ports, new or used.
Figure 37-3. Number of Monitoring Ports on the S5000
A source port may only be monitored by one destination port (Message 3), but a destination port may
monitor more than one source port. Given these parameters, Figure 37-1 illustrates conceptually the
possible port monitoring configurations on the S5000.
Message 2 One Destination Port in a Monitoring Session Error Message on the S5000
% Error: Exceeding max MG ports for this MD port pipe.
Message 3 One Destination Port per Source Port Error Message
% Error: MD port is already being monitored.
Dell(conf)#mon ses 300
Dell(conf-mon-sess-300)#source gig 0/17 destination gig 0/4 direction tx
% Error: Exceeding max MG ports for this MD port pipe.
Dell(conf-mon-sess-300)#
Dell(conf-mon-sess-300)#source gig 0/17 destination gig 0/1 direction tx
Dell(conf-mon-sess-300)#do show mon session
SessionID Source Destination Direction Mode Type
--------- ------ ----------- --------- ---- ----
0 Te 0/13 Te 0/1 rx interface Port-based
10 Te 0/14 Te 0/2 rx interface Port-based
20 Te 0/15 Te 0/3 rx interface Port-based
30 Te 0/16 Te 0/37 rx interface Port-based
300 Te 0/17 Te 0/1 tx interface Port-based
Dell(conf-mon-sess-300)#do show mon session
SessionID Source Destination Direction Mode Type
--------- ------ ----------- --------- ---- ----
0 Te 0/13 Te 0/1 rx interface Port-based
10 Te 0/14 Te 0/2 rx interface Port-based
20 Te 0/15 Te 0/3 rx interface Port-based
30 Te 0/16 Te 0/37 rx interface Port-based
100 Te 0/25 Te 0/38 tx interface Port-based
110 Te 0/26 Te 0/39 tx interface Port-based
300 Te 0/17 Te 0/1 tx interface Port-based
Dell(conf-mon-sess-300)#