Reference Guide

642 | NPIV Proxy Gateway
www.dell.com | support.dell.com
Applying an FCoE map on server-facing Ethernet ports
You can apply multiple FCoE maps on an Ethernet port or port channel. When you apply an FCoE map on
a server-facing port or port channel:
The port is configured to operate in hybrid mode (accept both tagged and untagged VLAN frames).
The associated FCoE VLAN is enabled on the port or port channel.
When you enable a server-facing Ethernet port, the servers respond to the FIP advertisements by
performing FLOGIs on upstream virtualized FCF ports. The NPG forwards the FLOGIs as fabric
discovery (FDISC) messages to a SAN switch.
Step Task Command Command Mode
1 Configure a server-facing Ethernet port or port
channel with an FCoE map.
interface {tengigabitEthernet
slot
/port | fortygigabitEthernet
slot
/port | port-channel num}
CONFIGURATION
2 Apply the FCoE/FC configuration in an FCoE map on
the Ethernet port.
Repeat this step to apply an FCoE map to more than
one port; for example:
Dell# interface tengigabitEthernet 0/0
Dell(config-if-te-0/0)# fcoe-map SAN_FABRIC_A
Dell# interface port-channel 3
Dell(config-if-po-3)# fcoe-map SAN_FABRIC_A
Dell# interface fortygigabitEthernet 0/48
Dell(config-if-fo-0/0)# fcoe-map SAN_FABRIC_A
fcoe-map map-name
INTERFACE
or INTERFACE
PORT_CHANNEL
3 Enable the port for FCoE transmission using the map
settings.
no shutdown
INTERFACE