Reference Guide

S5000 Debugging and Diagnostics | 1027
Sample buffer profile configuration
The two general types of network environments are sustained data transfers and voice/data. Dell
Networking recommends a single-queue approach for data transfers (Figure 57-11).
Figure 57-11. Single Queue Application for S5000 with Default Packet Pointers
Troubleshooting packet loss
The show hardware stack-unit command is intended primarily to troubleshoot packet loss.
show hardware stack-unit cpu data-plane statistics
show hardware stack-unit cpu party-bus statistics
show hardware stack-unit 0-11 drops unit 0-0 port 0-63
show hardware stack-unit 0-11 stack-port 0-63
show hardware stack-unit 0-11 unit 0-1 {counters | details | port-stats [detail] | register | execute-shell-cmd |
ipmc-replication | table-dump}
:
show hardware {layer2| layer3} {e.g. acl |in acl} stack-unit 0-11 port-set 0-0
show hardware layer3 qos stack-unit 0-7 port-set 0-0
show hardware ipv6 {e.g.-acl |in-acl} stack-unit 0-11 port-set 0-0
show hardware system-flow layer2 stack-unit 0-11 port-set 0-0 [counters]
clear hardware stack-unit 0-11 counters
clear hardware stack-unit 0-11 unit 0-0 counters
clear hardware stack-unit 0-11 cpu data-plane statistics
clear hardware stack-unit 0-11 cpu party-bus statistics
clear hardware stack-unit 0-11 stack-port 0-63
!
buffer-profile fp fsqueue-fp
buffer dedicated queue0 3 queue1 3 queue2 3 queue3 3 queue4 3 queue5 3 queue6 3 queue7 3
buffer dynamic 1256
!
buffer-profile fp fsqueue-hig
buffer dedicated queue0 3 queue1 3 queue2 3 queue3 3 queue4 3 queue5 3 queue6 3 queue7 3
buffer dynamic 1256
!
buffer fp-uplink stack-unit 0 port-set 0 buffer-policy fsqueue-hig
buffer fp-uplink stack-unit 0 port-set 1 buffer-policy fsqueue-hig
!
Interface range te 0/1 - 48
buffer-policy fsqueue-fp
Dell#show run int te 0/10
!
interface TenGigabitEthernet 0/10
no ip address