Reference Guide
S5000 Debugging and Diagnostics | 1021
Troubleshooting an under-voltage condition
To troubleshoot an under-voltage condition, check that the correct number of power supplies are installed
and their Status LEDs are lit.
The SNMP traps and OIDs in Table 57-3 provide information about environmental monitoring hardware
and hardware components.
Table 57-3. SNMP Traps and OIDs
OID String OID Name Description
Receiving power
.1.3.6.1.4.1.6027.3.10.1.2.5.1.6 chSysPortXfpRecvPower OID to display the receiving power of the connected
optics.
Transmitting power
.1.3.6.1.4.1.6027.3.10.1.2.5.1.8 chSysPortXfpTxPower OID to display the transmitting power of the
connected optics.
Temperature
.1.3.6.1.4.1.6027.3.10.1.2.5.1.7 chSysPortXfpRecvTemp OID to display the Temperature of the connected
optics.
Note: These OIDs will only be generated if the
CLI command
enable optic-info-update-interval is
enabled.
Hardware MIB Buffer Statistics
.1.3.6.1.4.1.6027.3.16.1.1.4 fpPacketBufferTable View the modular packet buffers details per stack
unit and the mode of allocation.
.1.3.6.1.4.1.6027.3.16.1.1.5 fpStatsPerPortTable View the forwarding plane statistics containing the
packet buffer usage per port per stack unit.
.1.3.6.1.4.1.6027.3.16.1.1.6 fpStatsPerCOSTable View the forwarding plane statistics containing the
packet buffer statistics per COS per port.