Reference Guide
S5000 Debugging and Diagnostics | 1013
Figure 57-2. Verifying the Offline/Online Status of a Stack Unit
3. Start diagnostics on the unit using the command diag, as shown in Figure 57-3. When the tests are
complete, the system displays syslog Message 2, and automatically reboots the unit. Diagnostic results
are printed to a file in the flash using the filename format TestReport-SU-<stack-unit>.txt.
Message 2 Offline Diagnostics Complete
Dell#00:09:32 : Diagnostic test results are stored on file: flash:/TestReport-SU-1.txt
00:09:37: %S5000:1 %DIAGAGT-6-DA_DIAG_DONE: Diags finished on stack unit 1
Diags completed... Rebooting the system now!!!
Dell#show system brief | no-more
Stack MAC : 5c:f9:dd:ee:ff:c0
Reload-Type : normal-reload [Next boot : normal-reload]
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
--------------------------------------------------------------------------------------
0 Management online S5000 S5000 9-0-1-0 64
1 Member not present
2 Member not present
3 Member not present
4 Member not present
5 Member not present
6 Member not present
7 Member not present
8 Member not present
9 Member not present
10 Member not present
11 Member not present
-- Module Info --
Unit Module No Status Module Type Ports
---------------------------------------------------------------------------
0 0 online S5000-MOD-12XETH10-F 12
0 1 not present No Module 0
0 2 online S5000-MOD-12XETH10-F 12
0 3 not present No Module 0
-- Power Supplies --
Unit Bay Status Type FanStatus
--------------------------------------------------------------------------------------
0 0 up DC up
0 1 up DC up
-- Fan Status --
Unit Bay TrayStatus Fan0 Speed Fan1 Speed Fan2 Speed Fan3 Speed
--------------------------------------------------------------------------------------
0 0 absent or down
0 1 up up 4800 up 4800 up 4800 up 4800
0 2 up up 4800 up 4800 up 4800 up 4800
0 3 absent or down
Dell#