Users Guide
– interval: (Optional) species the number of seconds in each polling cycle.
– seconds: (Optional) the number of seconds in each polling cycle. The value is ranged from 5 to 3,600 (Seconds). The
default is
1,800 (as dened in RFC-2819).
Example of the rmon collection history Command
To remove a specied RMON history group of statistics collection, use the no form of this command.
The following command example enables an RMON MIB collection history group of statistics with an ID number of 20 and an owner
of john, both the sampling interval and the number of buckets use their respective defaults.
Dell(conf-if-mgmt)#rmon collection history controlEntry 20 owner john
744