Users Guide
Te 1/20 Down Auto Auto --
Te 1/21 Down Auto Auto --
The following lists the show interfaces status command example eld descriptions.
Field Description
Port Server-facing 10GbE Ethernet (Te), 40GbE Ethernet (Fo), or fabric-facing Fibre Channel (Fc) port with slot/
port information.
Description Text description of port.
Status Operational status of port:
• Ethernet ports — up (transmitting FCoE and LAN storage trac) or down (not transmitting trac).
• Fibre Channel ports — up (link is up and transmitting FC trac) or down (link is down and not
transmitting FC trac), link-wait (link is up and waiting for FLOGI to complete on peer SW port), or
removed (port has been shut down).
Speed Transmission speed (in Megabits per second) of Ethernet and FC iports, including auto-negotiated speed
(Auto).
Duplex Data transmission mode:
• Full (allows communication in both directions at the same time)
• Half (allows communication in both directions but not at the same time)
• Auto (auto-negotiated transmission).
VLAN VLAN IDs of the VLANs in which the port is a member.
Example of the show fcoe-map Command
Dell# show fcoe-map brief
Fabric-Name Fabric-Id Vlan-Id FC-MAP FCF-Priority Config-State Oper-State
fid_1003 1003 1003 0efc03 128 ACTIVE UP
fid_1004 1004 1 004 0efc04 128 ACTIVE DOWN
Dell# show fcoe-map fid_1003
Fabric Name fid_1003
Fabric Id 1003
Vlan Id 1003
Vlan priority 3
FC-MAP 0efc03
FKA-ADV-Period 8
Fcf Priority 128
Config-State ACTIVE
Oper-State UP
Members
Fc 0/0
Te 0/14 Te 0/16
The following lists the show fcoe-map command example eld descriptions.
Field
Description
Fabric-Name Name of a SAN fabric.
Fabric ID The ID number of the SAN fabric to which FC trac is forwarded.
VLAN ID The dedicated VLAN used to transport FCoE storage trac between servers and a fabric over the NPG.
The congured VLAN ID must be the same as the fabric ID.
VLAN priority FCoE trac uses VLAN priority 3. (This setting is not user-congurable.)
580