Users Guide
Enable an Upstream FC Port
Dell(config)# interface fibrechannel 0/0
Dell(config-if-fc-0)# no shutdown
Enable a Downstream Ethernet Port
Dell(config)#interface tengigabitEthernet 0/0
Dell(conf-if-te-0)# no shutdown
Enable a Downstream Port Channel
Dell(config)# interface port-channel 0/3
Dell(config-po-3)# no shutdown
Display NPIV Proxy Gateway Information
To display information on NPG operation, use the following show commands.
Command Description
show
interfaces
status
Displays the operational status of Ethernet and Fibre Channel interfaces on an NPG.
show fcoe-map
[brief | map-
name]
Displays the Fibre Channel and FCoE conguration parameters in FCoE maps. Enter the brief keyword to
display an overview of currently congured FCoE maps.
Enter the name of an FCoE map to display the FC and FCoE parameters congured in the map to apply on
the Ethernet (FCoE) and FC ports.
show qos dcb-
map map-name
Displays conguration parameters in a specied DCB map.
show npiv
devices
[brief]
Displays information on FCoE and FC devices currently logged in to the NPG.
show fc switch
Displays the FC mode of operation and worldwide node (WWN) name.
show vlan
Displays the VLANs currently congured on the switch, including the VLANs dedicated to carrying only FC/
FCoE trac from a server to a SAN fabric.
Example of the show interfaces status Command
Dell# show interfaces status
Port Description Status Speed Duplex Vlan
Fc 0/0 Up 8000 Mbit Auto --
Fc 0/1 Down Auto Auto --
Fc 0/2 Down Auto Auto --
Fc 0/3 Down Auto Auto --
Fc 0/4 Down Auto Auto --
Fc 0/5 Down Auto Auto --
Fc 0/6 Down Auto Auto --
Fc 0/7 Down Auto Auto --
Fc 0/8 Down Auto Auto --
Fc 0/9 Down Auto Auto --
Fc 0/10 Down Auto Auto --
Fc 0/11 Down Auto Auto --
Te 1/12 Down Auto Auto --
Te 1/13 Down Auto Auto --
Te 1/14 Down Auto Auto --
Te 1/15 Down Auto Auto --
Te 1/16 Down Auto Auto --
Te 1/17 Down Auto Auto --
Te 1/18 Down Auto Auto --
Te 1/19 Up 10000 Mbit Full --
NPIV Proxy Gateway
579