Users Guide
• When you apply the FCoE map to a server-facing Ethernet port in ENode mode, ACLs are automatically congured to allow only
FCoE trac from servers that perform a successful FLOGI on the FC switch. All other trac on the VLAN is denied.
You can specify one or more upstream N ports in an FCoE map. The FCoE map also contains the VLAN ID of the dedicated VLAN
used to transmit FCoE trac between the SAN fabric and servers.
NPIV Proxy Gateway: Protocol Services
An S5000 NPG provides the following protocol services.
• Fibre Channel service to create N ports and log in to an upstream FC switch.
• FCoE service to perform:
– Virtualization of FC N ports on an NPG so that they appear as FCoE FCFs to downstream servers.
– NPIV service to perform the association and aggregation of FCoE servers to upstream F ports on core switches (through N
ports on the NPG). Conversion of server FLOGIs and FDISCs, which are received over S5000 ENode ports, are converted
into FDISCs addressed to the upstream F ports on core switches.
NPIV Proxy Gateway Functionality
An NPG provides the following functionality in a storage area network.
• FIP snooping bridge that provides security for FCoE trac using ACLs (refer to FCoE Transit chapter).
• FCoE gateway that provides FCoE-to-FC bridging. N-port virtualization using FCoE maps exposes upstream F ports as FCF
ports to downstream server-facing ENode ports on the NPG (refer FCoE Maps).
NPIV Proxy Gateway: Terms and Denitions
The following table describes the terms used in an NPG conguration on the S5000.
Table 60. S5000 NPIV Proxy Gateway: Terms and Denitions
Term Description
FC port Fibre Channel port on an S5000 FC module that operates in
autosensing, 2–, 4–, or 8-Gigabit mode. On an NPIV proxy
gateway, an FC port can be used as a downlink for a server
connection and an uplink for a fabric connection.
F port Port mode of an FC port connected to an end node (N) port on
an S5000 NPIV proxy gateway.
N port Port mode of an S5000 FC port that connects to an F port on
an FC switch in a SAN fabric. On an S5000 NPIV proxy gateway,
an N port also functions as a proxy for multiple server CNA-port
connections.
ENode port Port mode of a server-facing S5000 Ethernet port that provides
access to FCF functionality on a fabric.
CNA port N-port functionality on an FCoE-enabled server port. A
converged network adapter (CNA) can use one or more
Ethernet ports. CNAs can encapsulate Fibre Channel frames in
Ethernet for FCoE transport and de-encapsulate Fibre Channel
frames from FCoE to native Fibre Channel.
DCB map Template used to congure DCB parameters, including priority-
based ow control (PFC) and enhanced transmission selection
(ETS), on CEE ports.
Fibre Channel fabric Network of Fibre Channel devices and storage arrays that inter-
operate and communicate.
572
NPIV Proxy Gateway