Users Guide
Field Description
Information:
Fibrechannel 0/0 is
down, FC link is
down
Administrative state of the Fibre Channel interface (up/no shutdown or down/ shutdown) and operational
state of the FC link (up or down).
Pluggable media
present, SFP+ type
Pluggable optic is inserted in the port or not, and the SFP+ optic type.
Wavelength Wavelength of the inserted optic.
SFP+ receive power Power received on SFP+ optic.
Interface index Index number of FC port.
MTU Maximum transmission unit on interface (not user-congurable; xed at 2148 bytes).
LinkSpeed Congured transmission speed of the FC port when the port link is down or current speed when the port
link is up. Valid link speeds are: auto (port autosenses speed of peer FC port), 2G, 4G, or 8G.
Port type, Max BB
credits
The FC port type is xed at N (end node port) in NPG mode and are automatically set to F (fabric port) or E
(extended port) in Fabric Services. The maximum number of buer-to-buer (BB) credits available is xed
at 16.
WWN, FC-ID Factory-provided world-wide name (WWN) of FC port (in hexadecimal) that uniquely identies the port on
the switch (not user-congurable) and the unique FC port ID (24-bit in hexadecimal) received from an FC
switch in the fabric after a successful login.
Last clearing of
“show interface”
counters
Elapsed time since the interface counters displayed in show interfaces output were last cleared.
Statistics:
BBCR_FrameFailure
s
Number of link resets due to frames lost during buer-to-buer credit recovery (BBCR) period.
BBCR_RRDYFrame
Failures
Number of link resets due to multiple Receiver Ready (R_RDY) frames received during the credit recovery
period.
Class2FramesIn Number of Class 2 frames received.
Class2FramesOut Number of Class 2 frames transmitted.
Class3FramesIn Number of Class 3 frames received.
Class3FramesOut Number of Class 3 frames transmitted.
Class3Discards Number of Class 3 frames dropped.
DecodeErrors Number of decode errors.
FBusy Number of Fabric port Busy (F_BSY) frames received.
FReject Number of Fabric port Reject (F_RJT) frames received.
AddressErrors Number of frame-address ID errors.
LinkFailures Number of link failures.
InvalidCRC Number of cyclic redundancy check (CRC) errors.
TotalRxBytes Number of bytes received.
TotalTxBytes Number of bytes transmitted.
338