Users Guide
EXEC Privilege mode
show hardware stack-unit {0-11} stack-port {0-64}
• View the counters in the eld processors of the stack unit.
EXEC Privilege mode
show hardware stack-unit {0-11} unit {0-0} counters
• View the details of the FP Devices and Hi gig ports on the stack-unit.
EXEC Privilege mode
show hardware stack-unit {0-11} unit {0-0} details
• Execute a specied bShell command from the CLI without going into the bShell.
EXEC Privilege mode
show hardware stack-unit {0-11} unit {0-0} execute-shell-cmd {command}
• View the Multicast IPMC replication table from the bShell.
EXEC Privilege mode
show hardware stack-unit {0-11} unit {0-0} ipmc-replication
• View the internal statistics for each port-pipe (unit) on per port basis.
EXEC Privilege mode
show hardware stack-unit {0-11} unit {0-0} port-stats [detail]
• View the stack-unit internal registers for each port-pipe.
EXEC Privilege mode
show hardware stack-unit {0-11} unit {0-0} register
• View the tables from the bShell through the CLI without going into the bShell.
EXEC Privilege mode
show hardware stack-unit {0-11} unit {0-0} table-dump {table name}
Enabling Environmental Monitoring
The S5000 components use environmental monitoring hardware to detect transmit power readings, receive power readings, and
temperature updates.
To receive periodic power updates, you must enable the following command.
• Enable environmental monitoring.
enable optic-info-update interval
Example of the show interfaces transceiver Command
Dell#show int tengig 0/1 transceiver
SFP is present
SFP+ 1 Serial Base ID fields
SFP+ 1 Id = 0x03
SFP+ 1 Ext Id = 0x04
SFP+ 1 Connector = 0x07
SFP+ 1 Transceiver Code = 0x10 0x00 0x00 0x00 0x00 0x00 0x00 0x00
SFP+ 1 Encoding = 0x06
SFP+ 1 BR Nominal = 0x67
SFP+ 1 Length(SFM) Km = 0x00
SFP+ 1 Length(OM3) 2m = 0x00
SFP+ 1 Length(OM2) 1m = 0x08
SFP+ 1 Length(OM1) 1m = 0x03
SFP+ 1 Length(Copper) 1m = 0x00
SFP+ 1 Vendor Rev = A
SFP+ 1 Laser Wavelength = 850 nm
SFP+ 1 CheckCodeBase = 0x9e
1008
S5000 Debugging and Diagnostics










