Users Guide
Version Description
8.1.1.0 Introduced on the E-Series ExaScale.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
pre-Version 6.2.1.0 Introduced on the E-Series.
Usage Information In the Example, the delta column displays changes since the last screen refresh.
The following are the monitor command menu options.
Key Description
systest-3 Displays the host name assigned to the system.
monitor time Displays the amount of time since the monitor interface command was
entered.
time Displays the amount of time the chassis is up (since last reboot).
m Change the view from a single interface to all interfaces on the line card or visa-
versa.
c Refresh the view.
b Change the counters displayed from Packets on the interface to Bytes.
r Change the [delta] column from change in the number of packets/bytes in the last
interval to rate per second.
l Change the view to the next interface on the line card, or if in line card mode, the
next line card in the chassis.
a Change the view to the previous interface on the line card, or if in line card mode,
the previous line card in the chassis.
T Increase the screen refresh rate.
t Decrease the screen refresh rate.
q Return to the CLI prompt.
Example (Single
Interface)
Example (All
Interfaces)
systest-3 Monitor time: 00:01:31 Refresh Intvl.: 2s Time: 03:54:14
Interface Link In Packets [delta] Out Packets
[delta]
Te 0/0 Down 0 0 0 0
Te 0/1 Down 0 0 0 0
Te 0/2 Up 61512 52 66160 42
Te 0/3 Up 63086 20 9405888 24
Te 0/4 Up 14697471418 2661481 13392989657
2661385
Te 0/5 Up 3759 3 161959604 832816
Te 0/6 Up 4070 3 8680346 5
Te 0/7 Up 61934 34 138734357 72
Te 0/8 Up 61427 1 59960 1
Te 0/9 Up 62039 53 104239232 3
Te 0/10 Up 17740044091 372 7373849244 79
Te 0/11 Up 18182889225 44 7184747584 138
Te 0/12 Up 18182682056 0 3682 1
Te 0/13 Up 18182681434 43 6592378911 144
Interfaces
743