Users Guide
61
Stacking Commands
All commands in this chapter are specic to the Dell Networking OS on the S5000 switch.
The commands are always available and operational. You can use the commands to pre-congure a switch so that the conguration
settings are invoked when the switch is attached to other S5000 units.
For information about using the S5000 stacking feature, refer to the Stacking chapter in the Dell Networking OS Conguration
Guide for the S5000.
CAUTION: You cannot enable S5000 stacking simultaneously with virtual link trunking (VLT). If you enable both at the
same time, unexpected behavior occurs.
redundancy disable-auto-reboot stack-unit
Prevent the S5000 stack management unit, stack member unit, and standby unit from rebooting if they fail.
S5000
Syntax
redundancy disable-auto-reboot stack-unit [members | 0-11]
To re-enable the automatic reboot of a failed stack unit, use the no redundancy disable-auto-
reboot stack-unit command.
Defaults Disabled (a failed switch automatically reboots).
Command Modes CONFIGURATION
Command History
Version 9.0(1.3) Introduced on the S5000.
Usage Information The range is 0 to 11. Entering this command disables the automatic reboot and keeps a failed stack unit in
the Failed state. A failed switch does not reboot until you manually reload it. The disabling of the automatic
reboot is displayed in the running-cong.
Related Commands show redundancy – displays the current redundancy status.
redundancy force-failover stack-unit
Force the standby unit in the stack to become the management unit.
Syntax
redundancy force-failover stack-unit
Parameters
stack-unit Enter the stack unit.
1772
Stacking Commands