Users Guide

-- Power Supplies --
Unit Bay Status Type FanStatus
----------------------------
0 0 up AC up
0 3 up AC up
-- Thermal Sensor Readings (degree C) --
-- Unit 0--
S0 S1 S2 S3 S4 S5 S6 S7
---------------------------------------
BASE BOARD 70 38 41 42 43 57 39 40
Module 0 43 44 36 37 33 31 - -
Module 1 43 44 36 31 32 31 - -
Module 2 42 42 36 32 30 31 - -
Module 3 42 43 36 31 31 31 - -
Dell#show environment thermal-sensor
-- Thermal Sensor Readings (degree C) --
-- Unit 0 --
S0 S1 S2 S3 S4 S5 S6 S7
------------------------------------------
BASE BOARD 40 26 26 29 28 41 26 28
Module 0 30 31 22 19 23 20 - -
Module 1 28 29 21 - - - - -
Module 2 20 25 24 21 22 23 - -
Module 3 20 25 24 - - - - -
show inventory
Display the S-Series or Z-Series switch type, components (including media), and Dell Networking Operating System (OS), including
hardware identication numbers and congured protocols.
Syntax
show inventory [media slot]
Parameters
media slot (OPTIONAL) Enter the keyword media then the stack ID of the stack member for
which you want to display pluggable media inventory.
NOTE: This parameter is available but not supported in Dell Networking
Operating System version 8.3.11.4. Because stacking is not supported, if
you use this parameter, the output displays “Media not present or
accessible” (refer to the
Usage Information
section).
Defaults none
Command Modes CONFIGURATION
Command History
This guide is platform-specic. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.8(0.0P5) Introduced on the S4048-ON.
Control and Monitoring