Reference Guide
warning-only (OPTIONAL) Enter the keyword warning-only to set the
router to send a log message when the maximum value is
reached. If this parameter is not set, the router stops peering
when the maximum number of prefixes is reached.
Defaults threshold = 75
Command
Modes
ROUTER BGP Address Family (conf-router_bgp_af)
Command
History
Version 7.8.1.0 Introduced on the S-Series.
Version 7.7.1.0 Introduced on the C-Series.
Version 7.6.1.0 Introduced IPv6 MGBP on the E-Series.
neighbor next-hop-self
Allows you to configure the router as the next hop for a BGP neighbor.
C-Series, E-Series TeraScale, S-Series
Syntax
neighbor {ip-address | peer-group-name} next-hop-self
To return to the default setting, use the no neighbor {ip-address | peer-
group-name} next-hop-self command.
Parameters
ip-address Enter the IP address of the neighbor in dotted decimal
format.
peer-group-
name
Enter the name of the peer group.
Defaults Disabled.
Command
Modes
ROUTER BGP Address Family (conf-router_bgp_af)
Command
History
Version 7.8.1.0 Introduced on the S-Series.
Version 7.7.1.0 Introduced on the C-Series.
Version 7.6.1.0 Introduced IPv6 MGBP on the E-Series.
Border Gateway Protocol
545