Reference Guide

Version Description
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.2.1.0 Introduced on the E-Series ExaScale (IPv6).
8.1.1.0 Introduced on the E-Series ExaScale (IPv4).
7.8.1.0 Increased the name string to accept up to 140 characters.
Prior to 7.8.1.0, names were up to 16 characters long.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
7.4.1.0 Introduced on the E-Series.
Usage
Information
When you have exhausted all the sequence numbers, this feature permits re-
assigning a new sequence number to entries of an existing access-list.
seq
Assign a sequence number to a deny or permit filter in an IP access list while creating the filter.
Syntax
seq sequence-number {deny | permit} {source [mask] | any | host
ip-address}} [count [bytes]] [dscp value] [order] [fragments]
To delete a filter, use the no seq sequence-number command.
Parameters
sequence-
number
Enter a number from 0 to 4294967290.
deny Enter the keyword deny to configure a filter to drop packets
meeting this condition.
permit Enter the keyword permit to configure a filter to forward
packets meeting this criteria.
source Enter an IP address in dotted decimal format of the network
from which the packet was received.
mask (OPTIONAL) Enter a network mask in /prefix format (/x) or
A.B.C.D. The mask, when specified in A.B.C.D format, may be
either contiguous or non-contiguous.
any Enter the keyword any to specify that all routes are subject
to the filter.
host ip-address Enter the keyword host then the IP address to specify a host
IP address or hostname.
count (OPTIONAL) Enter the keyword count to count packets the
filter processes.
Access Control Lists (ACL)
243