Reference Guide
Version Description
8.3.19.0 Introduced on the S4820T.
8.3.7.0 Introduced on the S4810.
8.2.1.0 Introduced on the E-Series ExaScale. C-Series and S-Series
accept both bytes of the 2-byte S-Tag TPID.
8.2.1.0 Introduced on the E-Series ExaScale.
7.6.1.0 Introduced on the C-Series and S-Series.
E-Series original
Command
Usage
Information
For specific interoperability limitations regarding the S-Tag TPID, refer to the Dell
Networking OS Configuration Guide.
The four characters you enter in the CLI for number are interpreted, as shown in
the following table.
Number Resulting TPID
1 0x0001
10 0x0010
81 0x0081
8100 0x8100
Related
Commands
portmode hybrid — sets a port (physical ports only) to accept both tagged and
untagged frames. A port configured this way is identified as a hybrid port in report
displays.
vlan-stack trunk — specifies a Layer 2 port or port channel as a trunk port to the
Stackable VLAN network.
vlan-stack trunk
Specify a Layer 2 port or port channel as a trunk port to the Stackable VLAN network.
Syntax
vlan-stack trunk
To remove a trunk port designation from the selected interface, use the no vlan-
stack trunk command.
Defaults Not configured.
Command
Modes
INTERFACE
VLAN Stacking
2017