Reference Guide

Usage
Information
The dropEvent counter (sFlow samples dropped due to sub-sampling) shown in
the following example always displays a value of zero.
Example
Dell#show sflow
sFlow services are enabled
Egress Management Interface sFlow services are disabled
Global default sampling rate: 32768
Global default counter polling interval: 20
Global default extended maximum header size: 128 bytes
Global extended information enabled: none
1 collectors configured
Collector IP addr: 100.1.1.1, Agent IP addr: 1.1.1.2, UDP
port: 6343 VRF: Default
0 UDP packets exported
0 UDP packets dropped
0 sFlow samples collected
stack-unit 1 Port set 1
Te 1/1: configured rate 16384, actual rate 16384 <<<
sampling rate based on line speed if global sampling rate is
default
Dell#
show sflow stack-unit
Display the sFlow information on a stack-unit.
S5000
Syntax
show sflow stack—unit {unit-number}
Parameters
unit-number (OPTIONAL) Enter the stack-unit keyword followed by the
unit number. The range is 0 to 11.
Command
Modes
EXEC
EXEC Privilege
Command
History
Version 9.0(1.3) Introduced on S5000.
Usage
Information
The dropEvent counter (sFlow samples dropped due to sub-sampling) shown in
the Example below always displays a value of zero.
Example
Dell#show sflow stack-unit 0
Stack-Unit 0
Samples rcvd from h/w :0
Total UDP packets exported :0
UDP packets exported :0
1888
sFlow