Reference Guide

Version Description
Version 7.8.1.0 The Boot Flash field displays the code level for boot code
2.8.1.1 and newer, while older boot codes display as
"Present".
Version 7.7.1.0 Added Master Priority field.
Version 7.6.1.0 Introduced on the S-Series.
Example (show
system stack
unit – disabled
ports)
Example (show
system brief)
Dell#show system brief
Stack MAC : 90:b1:1c:f4:9b:79
Reload-Type : normal-reload [Next boot :
normal-reload]
-- Stack Info --
Unit UnitType Status ReqTyp
CurTyp Version Ports
---------------------------------------------------------------
---------------------
0 Management online S6000
S6000 9-4(0-168) 128
1 Member not present
2 Member not present
3 Member not present
4 Member not present
5 Member not present
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
---------------------------------------------------------------
------------
0 0 down UNKNOWN down 0
0 1 up AC up 6600
-- Fan Status --
Unit Bay TrayStatus Fan0 Speed Fan1 Speed
---------------------------------------------------------------
---------------------
0 0 up up 7072 up 7072
0 1 up up 7021 up 7072
0 2 up up 7021 up 7021
Speed in RPM
Example
(S6000)
Dell#show system
Stack MAC : 90:b1:1c:f4:9b:79
Reload-Type : normal-reload [Next boot :
normal-reload]
-- Unit 0 --
Unit Type : Management Unit
Status : online
Next Boot : online
Control and Monitoring
163