Reference Guide
Command
History
Version 9.0(1.3) Introduced on the S5000 configured as an NPIV proxy
gateway.
Usage
Information
FCoE storage traffic received from servers on an S5000 NPIV proxy gateway is de-
capsulated into Fibre Channel packets and forwarded over FC links to SAN switches
in a specified fabric. You must configure a separate FCoE VLAN for each fabric to
which FCoE traffic is forwarded. Any non-FCoE traffic sent on a dedicated FCoE
VLAN will be dropped.
You configure the association between a dedicated VLAN, which carries FCoE
traffic from server CNAs over the NPIV proxy gateway to a SAN fabric in which
destination storage arrays are installed, in an FCoE map by using the fabric id
vlan command.
When you apply an FCoE map to a server-facing Ethernet port, the port is
automatically configured as a tagged member of the FCoE VLAN.
For more information about VLANs and the commands to configure them, refer to
the Virtual LAN (VLAN) Commands section of the Layer 2 chapter.
Example (Single
Range)
Dell(conf)#interface vlan 10
Dell(conf-if-vl-3)#
Related
Commands
fcoe-map — creates an FCoE map which contains the parameters used in the
communication between servers and a SAN fabric.
show fcoe-map— displays the Fibre Channel and FCoE configuration parameters in
FCoE maps.
keepalive
In an FCoE map, enable the monitoring of FIP keepalive messages (if it is disabled).
S5000
Syntax
keepalive
Parameters None
Defaults FIP keepalive monitoring is enabled on Ethernet and Fibre Channel interfaces.
Command
Modes
FCOE MAP
Command
History
Version 9.0(1.3) Introduced on the S5000.
NPIV Proxy Gateway
1443