Reference Guide

940 | Stacking
www.dell.com | support.dell.com
2 Member not present
3 Member not present
4 Member not present
5 Member not present
6 Member not present
7 Member not present
8 Member not present
9 Member not present
10 Member not present
11 Member not present
-- Power Supplies --
Unit Bay Status Type FanStatus
---------------------------------------------------------------------------
0 0 down DC down
0 1 up DC up
1 0 absent absent
1 1 up AC up
-- Fan Status --
Unit Bay TrayStatus Fan0 Speed Fan1 Speed
--------------------------------------------------------------------------------
0 0 up up 6960 up 6720
0 1 up up 6720 up 6720
1 0 up up 6960 up 6720
1 1 up up 6720 up 6720
Speed in RPM
stack-1#
Recover from a Card Mismatch State on an S-Series Stack
A card mismatch occurs if the stack has a provision for the lowest available stack number which does not
match the model of a newly added unit. See the following example. To recover, disconnect the new unit.
Then, either:
remove the provision from the stack, then reconnect the standalone unit, or
renumber the standalone unit with another available stack number on the stack.
Figure 46-15. Recovering from a Card Mismatch State on an S-Series Stack (S50N and S25N)
-----------------------------------STANDALONE UNIT BEFORE------------------------------------
Standalone#show system brief
Stack MAC : 00:01:e8:d5:ef:81
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
---------------------------------------------------------------------------
0 Management online S50V S50V 7.8.1.0 52
1 Member not present S50N
2 Member not present S50V
3 Member not present S50V
4 Member not present
5 Member not present
6 Member not present
7 Member not present
---------------------------------------STACK BEFORE------------------------------------------
Stack#show system brief
Stack MAC : 00:01:e8:d5:f9:6f
-- Stack Info --