Reference Guide

926 | Stacking
www.dell.com | support.dell.com
-- Fan Status --
Unit Bay TrayStatus Fan0 Speed Fan1 Speed
----------------------------------------------------------------------------
1 0 up up 9360 up 9360
1 1 up up 9360 up 9360
2 0 up up 7680 up 7680
2 1 up up 7920 up 7680
3 0 up up 9360 up 9360
3 1 up up 9360 up 9360
4 0 up up 9120 up 9120
4 1 up up 9120 up 9360
Speed in RPM
The following example shows how to configure two new S4810 or S4820T switches for stacking using
10G ports.
S4810-1(conf)#stack-unit 0 stack-group 0
Setting ports Te 0/0 Te 0/1 Te 0/2 Te 0/3 as stack group will make their interface configs obsolete after
a reload.
[confirm yes/no]:yes
S4810-2(conf)#stack-unit 0 stack-group 0
Setting ports Te 0/0 Te 0/1 Te 0/2 Te 0/3 as stack group will make their interface configs obsolete after
a reload.
[confirm yes/no]:yes
S4810-1#show system stack-ports
Topology: Ring
Interface Connection Link Speed Admin Link Trunk
(Gb/s) Status Status Group
------------------------------------------------------------------
0/0 1/0 10 up up
0/1 1/1 10 up up
0/2 1/2 10 up up
0/3 1/3 10 up up
S4810-1#
Add Units to an Existing S-Series Stack
Units can be added to an existing stack in one of three ways:
by manually assigning a new un-configured unit a position in an existing stack.
by adding a configured unit to an existing stack.
by merging two stacks.
If you are adding units to an existing stack, you can either:
allow FTOS to automatically assign the new unit a position in the stack, or
manually determine each units position in the stack by configuring each unit to correspond with the
stack before connecting it.
If you add a unit that has a stack number that conflicts with the stack, the stack assigns the first
available stack number, as shown in the examples below.