Reference Guide
Uplink Failure Detection (UFD) | 1503
Command
History
Example
FTOS#show running-config uplink-state-group
!
no enable
uplink state track 1
downstream GigabitEthernet 0/2,4,6,11-19
upstream TengigabitEthernet 0/48, 52
upstream PortChannel 1
!
uplink state track 2
downstream GigabitEthernet 0/1,3,5,7-10
upstream TengigabitEthernet 0/56,60
Related
Commands
show uplink-state-group
s S50 only
Display status information on a specified uplink-state group or all groups.
Syntax
show uplink-state-group [group-id] [detail]
Parameters
Defaults
None
Command Modes
EXEC
EXEC Privilege
Command
History
Example
FTOS# show uplink-state-group
Uplink State Group: 1 Status: Enabled, Up
Uplink State Group: 3 Status: Enabled, Up
Uplink State Group: 5 Status: Enabled, Down
Uplink State Group: 6 Status: Enabled, Up
Version 8.3.19.0 Introduced on S4820T
Version 8.3.12.0 Introduced on S4810
Version 8.4.2.3 Introduced on the S-Series S50.
show uplink-state-group Display status information on a specified uplink-state group or all
groups.
uplink-state-group Create an uplink-state group and enabling the tracking of upstream
links.
group-id Displays status information on a specified uplink-state group or all
groups. Valid group-id values are 1 to 16.
detail Displays additional status information on the upstream and
downstream interfaces in each group
Version 8.3.19.0 Introduced on S4820T
Version 8.3.12.0 Introduced on S4810
Version 8.4.2.3 Introduced on the S-Series S50.