Users Guide

For the Management interface on the stack-unit, enter the keyword
ManagementEthernet then the slot/port information. The slot range is from
0 to 1. The port range is 0.
For a port channel interface, enter the keywords port-channel then a
number.
The range is from 1 to 128.
For a Null interface, enter the keyword null then the Null interface number.
For a VLAN interface, enter the keyword vlan then a number from 1 to 4094.
For a stack-unit interface, enter the keyword stack-unit then the stack unit
number.
For a tunnel interface, enter the keyword tunnel then the tunnel interface
number. The range is from 1 to 16383.
brief (OPTIONAL) Enter the keyword brief to view a brief summary of the interfaces
and whether an IP address is assigned.
congured (OPTIONAL) Enter the keyword configured to display the physical interfaces
with non-default congurations only.
Command Modes
EXEC
EXEC Privilege
Command History
This guide is platform-specic. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.7(0.0) Introduced on the S6000-ON.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.5.1.0 Added support for 4-port 40G line cards on ExaScale.
8.3.7.0 Introduced on the S4810.
8.1.1.2 Supported on the E-Series ExaScale E600i.
8.1.1.0 Introduced on the E-Series ExaScale.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
pre-6.1.1.0 Introduced on the E-Series.
Usage Information The following describes the show ip interface command shown in the following example.
Lines Description
TenGigabitEthernet
1/1...
Displays the interface’s type, slot/port, and physical and line protocol status.
Internet address... States whether an IP address is assigned to the interface. If an IP address is
assigned, that address is displayed.
IP MTU is... Displays IP MTU value.
790
IPv4 Routing