Users Guide

Version Description
8.5.1.0 Added support for 4-port 40G line cards on ExaScale.
8.2.1.0 Increased number of VLANs on ExaScale to 4094 (was 2094).
8.1.1.0 Introduced on the E-Series ExaScale.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
E-Series Original command
ip tftp vrf
Congures an TFTP client with a VRF that is used to connect to the TFTP server.
Syntax
ip tftp [vrf vrf-name]
To undo the TFTP client conguration, use the no ip tftp [vrf vrf-name] command.
Parameters
vrf vrf-name Enter the keyword vrf and then the name of the VRF to specify the VRF that is
used by the TFTP client.
Defaults Disabled
Command Modes CONFIGURATION
Command History
This guide is platform-specic. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.7(0.0) Introduced on the S6000-ON.
9.5(0.0) Introduced on the Z9500.
9.4.(0.0) Introduced on the S-Series and Z9000.
Usage Information Use this command to make the TFTP clients VRF aware. The VRF name that you specify is used by the
TFTP client to reach the TFTP server. If no VRF is specied, then the default VRF is used.
Related Commands
ftp-server topdir — sets the directory to be used for incoming FTP connections.
ftp-server username — sets a username and password for incoming FTP connections.
112
Control and Monitoring