Dell Command Line Reference Guide for the S4810 System 9.8(0.
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright, 2009 – 2015 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws.
Contents 1 About this Guide.............................................................................................................41 Objectives......................................................................................................................................................................... 41 Audience...........................................................................................................................................................................
Control and Monitoring................................................................................................. 86 asf-mode..........................................................................................................................................................................86 banner exec......................................................................................................................................................................87 banner login..............
show debugging..............................................................................................................................................................128 show environment.......................................................................................................................................................... 129 show inventory...................................................................................................................................................
802.1X.......................................................................................................................... 174 debug dot1x.....................................................................................................................................................................174 dot1x auth-fail-vlan..........................................................................................................................................................175 dot1x auth-server..
permit....................................................................................................................................................................... 217 permit tcp................................................................................................................................................................. 218 permit udp....................................................................................................................................................
set level.....................................................................................................................................................................261 set local-preference................................................................................................................................................. 262 set metric..........................................................................................................................................................
deny icmp (for Extended IPv6 ACLs).............................................................................................................................309 deny (for IPv6 ACLs)...................................................................................................................................................... 310 8 Access Control List (ACL) VLAN Groups and Content Addressable Memory (CAM).... 312 member vlan.............................................................................
bgp confederation peers...........................................................................................................................................347 bgp connection-retry-timer...................................................................................................................................... 348 bgp dampening........................................................................................................................................................
neighbor remove-private-as..................................................................................................................................... 388 neighbor route-map................................................................................................................................................. 389 neighbor route-reflector-client.................................................................................................................................
show ip bgp paths extcommunity.............................................................................................................................442 show ip extcommunity-list........................................................................................................................................443 IPv6 BGP Commands....................................................................................................................................................
description............................................................................................................................................................... 476 priority-list................................................................................................................................................................ 476 qos-policy-output ets..........................................................................................................................................
hardware watchdog.................................................................................................................................................. 513 show hardware layer2............................................................................................................................................... 513 show hardware layer3...............................................................................................................................................
ip dhcp snooping database renew............................................................................................................................ 554 ipv6 dhcp snooping database renew........................................................................................................................ 554 ip dhcp snooping trust............................................................................................................................................. 555 ipv6 dhcp snooping trust..
fip-snooping port-mode fcf............................................................................................................................................586 fip-snooping port-mode fcoe-trusted.............................................................................................................................587 show fip-snooping config...............................................................................................................................................
show patch.................................................................................................................................................................... 624 show processes restartable............................................................................................................................................624 show redundancy....................................................................................................................................................
interface range macro (define).................................................................................................................................668 interface range macro name.................................................................................................................................... 669 interface vlan............................................................................................................................................................
show port-channel-flow........................................................................................................................................... 722 Time Domain Reflectometer (TDR)................................................................................................................................ 723 tdr-cable-test...........................................................................................................................................................
ip helper-address hop-count disable...............................................................................................................................759 ip host............................................................................................................................................................................ 760 ip icmp source-interface..........................................................................................................................................
clear ipv6 mld_host........................................................................................................................................................ 816 maximum dynamic-routes-ipv6....................................................................................................................................... 817 ipv6 address autoconfig..................................................................................................................................................
debug isis spf-triggers....................................................................................................................................................855 debug isis update-packets..............................................................................................................................................856 default-information originate.........................................................................................................................................
router isis....................................................................................................................................................................... 893 set-overload-bit............................................................................................................................................................. 894 show config............................................................................................................................................
track ip.....................................................................................................................................................................939 untagged..................................................................................................................................................................940 Far-End Failure Detection (FEFD).................................................................................................................................
arp (for Multicast MAC Address)................................................................................................................................... 973 mac-address-table static (for Multicast MAC Address)..................................................................................................974 ip vlan-flooding...............................................................................................................................................................
show ip mroute.......................................................................................................................................................1009 show ip rpf............................................................................................................................................................... 1011 39 Neighbor Discovery Protocol (NDP).........................................................................1013 clear ipv6 neighbors...............................
41 Open Shortest Path First (OSPFv2 and OSPFv3).................................................... 1044 OSPFv2 Commands..................................................................................................................................................... 1044 area default-cost.................................................................................................................................................... 1044 area nssa.........................................................
show ip ospf database............................................................................................................................................ 1083 show ip ospf database asbr-summary.................................................................................................................... 1085 show ip ospf database external...............................................................................................................................
show ipv6 ospf database......................................................................................................................................... 1137 show ipv6 ospf interface......................................................................................................................................... 1139 show ipv6 ospf neighbor......................................................................................................................................... 1140 timers spf...
44 Port Monitoring.........................................................................................................1181 description..................................................................................................................................................................... 1181 monitor session............................................................................................................................................................. 1182 rate-limit..............
match ip dscp..........................................................................................................................................................1221 match ip precedence.............................................................................................................................................. 1222 match ip vlan..........................................................................................................................................................
default-information originate.........................................................................................................................................1258 default-metric...............................................................................................................................................................1259 description........................................................................................................................................................
hello-time..................................................................................................................................................................... 1300 max-age........................................................................................................................................................................ 1301 protocol spanning-tree rstp...........................................................................................................................
radius-server host...................................................................................................................................................1338 radius-server vrf..................................................................................................................................................... 1339 radius-server key.....................................................................................................................................................
ip ssh source-interface............................................................................................................................................1373 ip ssh vrf................................................................................................................................................................. 1374 show crypto............................................................................................................................................................
55 Simple Network Management Protocol (SNMP) and Syslog................................... 1408 SNMP Commands........................................................................................................................................................1408 show snmp............................................................................................................................................................. 1408 show snmp engineID........................................................
56 SNMP Traps............................................................................................................ 1449 57 Stacking...................................................................................................................1454 redundancy disable-auto-reboot................................................................................................................................... 1454 redundancy force-failover stack-unit...................................................
ntp authentication-key.................................................................................................................................................. 1491 ntp broadcast client...................................................................................................................................................... 1492 ntp disable.......................................................................................................................................................
dei honor...................................................................................................................................................................... 1525 dei mark........................................................................................................................................................................1526 member................................................................................................................................................
show vlt brief................................................................................................................................................................1557 show vlt backup-link.....................................................................................................................................................1558 show vlt counters..............................................................................................................................................
1 About this Guide This book provides information about the Dell Networking OS command line interface (CLI). This book also includes information about the protocols and features found in Dell Networking OS.
Information Icons This book uses the following information symbols: NOTE: The Note icon signals important operational information. CAUTION: The Caution icon signals information about situations that could result in equipment damage or loss of data. WARNING: The Warning icon signals information about hardware handling that could result in injury.
2 CLI Basics This chapter describes the command line interface (CLI) structure and command modes. The Dell Networking operating software commands are in a text-based interface that allows you to use the launch commands, change command modes, and configure interfaces and protocols. Accessing the Command Line When the system boots successfully, you are positioned on the command line in EXEC mode and not prompted to log in. You can access the commands through a serial console port or a Telnet session.
In this case, the user is “admin” on vty2. Obtaining Help As soon as you are in a command mode there are several ways to access help. To obtain a list of keywords at any command mode: Type a ? at the prompt or after a keyword. There must always be a space before the ?. To obtain a list of keywords with a brief functional description: Type help at the prompt. To obtain a list of available options: Type a keyword and then type a space and a ?.
• To navigate left or right in the Dell Networking OS command line, use the left and right Arrow keys. The shortcut key combinations at the Dell Networking OS command line are as follows: Key Combination Action CNTL-A Moves the cursor to the beginning of the command line. CNTL-B Moves the cursor back one character. CNTL-D Deletes the character at the cursor. CNTL-E Moves the cursor to the end of the line. CNTL-F Moves the cursor forward one character. CNTL-I Completes a keyword.
Using the Keyword no Command To disable, delete or return to default values, use the no form of the commands. For most commands, if you type the keyword no in front of the command, you disable that command or delete it from the running configuration. In this guide, the no form of the command is described in the Syntax portion of the command description.
Enabling Software Features on Devices Using a Command Option This capability to activate software applications or components on a device using a command is supported on the S4810, S4820T, and S6000, platforms. Starting with Release 9.4(0.0), you can enable or disable specific software functionalities or applications that need to run on a device by using a command attribute in the CLI interface.
show feature Verify the status of software applications, such as VRF, that are activated and running on a device. S4810 Syntax show feature Command Modes EXEC EXEC Privilege Command History Version 9.4(0.0) Introduced on the S4810, S4820T, and S6000. Usage Information You can activate VRF application on a device by using the feature vrf command in CONFIGURATION mode. The no feature vrf command is not supported on any of the platforms.
CONFIGURATION Mode In EXEC Privilege mode, use the configure command to enter CONFIGURATION mode and configure routing protocols and access interfaces. To enter CONFIGURATION mode: 1. Verify that you are logged in to EXEC Privilege mode. 2. Enter the configure command. The prompt changes to include (conf). From this mode, you can enter INTERFACE mode by using the interface command. CONTROL-PLANE Mode To manage control-plane traffic, use CONTROL-PLANE mode.
ECMP GROUP Mode To enable or configure traffic distribution monitoring on an ECMP link bundle, use ECMP GROUP mode. For more information, refer to ecmp_overview. To enter ECMP GROUP mode: 1. Verify that you are logged in to CONFIGURATION mode. 2. Enter the ecmp-group command then enter the ECMP group ID. The prompt changes to include (conf-ecmp-group-ecmpgroup-id). You can return to CONFIGURATION mode by using the exit command.
To enter FRRP mode: 1. Verify that you are logged in to CONFIGURATION mode. 2. Enter the protocol frrp command then the ring ID. The prompt changes to include (conf-frrp-ring-id). You can return to CONFIGURATION mode by using the exit command. INTERFACE Mode Use INTERFACE mode to configure interfaces or IP services on those interfaces. An interface can be physical (for example, a Gigabit Ethernet port) or virtual (for example, the Null interface). To enter INTERFACE mode: 1.
ISIS ADDRESS-FAMILY Mode To enable or configure IPv6 for ISIS, use ISIS ADDRESS-FAMILY mode. For more information, refer to Intermediate System to Intermediate System (IS-IS). To enter ISIS ADDRESS-FAMILY mode: 1. Verify that you are logged in to ROUTER ISIS mode. 2. Enter the command address-family ipv6 unicast. The prompt changes to include (conf-router_isis-af_ipv6). LLDP Mode To enable and configure Link Layer Discovery Protocol (LLDP), use LLDP mode.
To enter MONITOR SESSION mode: 1. Verify that you are logged in to CONFIGURATION mode. 2. Enter the monitor session command then the session ID. The prompt changes to include (conf-mon-sess-sessionID). MULTIPLE SPANNING TREE (MSTP) Mode To enable and configure MSTP, use MULTIPLE SPANNING TREE mode. For more information, refer to Multiple Spanning Tree Protocol (MSTP). To enter MULTIPLE SPANNING TREE mode: 1. Verify that you are logged in to CONFIGURATION mode. 2.
2. Enter the ip prefix-list command. Include a name for the prefix list. The prompt changes to include (conf-nprefixl). You can return to CONFIGURATION mode by using the exit command. PRIORITY GROUP Mode To create an ETS priority group, use PRIORITY GROUP mode. For more information, refer to ETS Commands. To enter PRIORITY GROUP mode: 1. Verify that you are logged in to CONFIGURATION mode. 2. Enter the priority-group command then the group name. The prompt changes to include (conf-pg).
ROUTER BGP Mode To enable and configure Border Gateway Protocol (BGP), use ROUTER BGP mode. For more information, refer to Border Gateway Protocol IPv4 (BGPv4) To enter ROUTER BGP mode: 1. Verify that you are logged in to CONFIGURATION mode. 2. Use the router bgp command then enter the AS number. The prompt changes to include (conf-router_bgp). You can return to CONFIGURATION mode by using the exit command.
SPANNING TREE Mode To enable and configure the Spanning Tree protocol, use SPANNING TREE mode. For more information, refer to Spanning Tree Protocol (STP). To enter SPANNING TREE mode: 1. Verify that you are logged in to CONFIGURATION mode. 2. Enter the protocol spanning-tree stp-id command. The prompt changes to include (conf-stp). You can return to CONFIGURATION mode by using the exit command. TRACE-LIST Mode To configure a Trace list, use TRACE-LIST mode. To enter TRACE-LIST mode: 1.
2. Enter the uplink-state-group command then the group ID number. The prompt changes to include (conf-uplink-stategroup-groupID).
3 File Management This chapter contains command line interface (CLI) commands needed to manage the configuration files as well as other file management commands. boot system Tell the system where to access the Dell Networking OS image used to boot the system. Syntax boot system {gateway ip address| stack-unit [{stack-unit-number | all] [default | primary {system {A: | B: | bmp-boot} | tftp: | | secondary]} To return to the default boot sequence, use the no boot system command.
Usage Information Version Description 9.7(0.0) Introduced the support for bmp-boot on the S-Series and Z-Series switches. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. To display these changes in the show bootvar command output, save the running configuration to the startup configuration (using the copy command) and reload system. The keyword bmp-boot is used only when the device boots up from BMP.
Version Description E-Series Original command. HTTP Copy via CLI Copy one file to another location. Dell Networking OS supports IPv4 and IPv6 addressing for FTP, TFTP, and SCP (in the hostip field). This feature is supported on S4810 platform. Syntax copy http://10.16.206.77/sample_file flash://sample_filecopy flash:// sample_file http://10.16.206.77/sample_file You can copy from the server to the switch and vice-versa. Parameters copy http: flash: Address or name of remote host []: 10.16.206.
compressed-config file-url Enter the keyword compressed-config to copy one file, after optimizing and reducing the size of the configuration file, to another location. Dell Networking OS supports IPv4 and IPv6 addressing for FTP, TFTP, and SCP (in the hostip field).
To copy a file from an external USB drive enter usbflash://filepath Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON.
You can compress the running configuration by grouping all the VLANs and the physical interfaces with the same property. Support to store the operating configuration to the startup config in the compressed mode and to perform an image downgrade without any configuration loss are provided. Two existing exec mode CLIs are enhanced to display and store the running configuration in the compressed mode. Example Dell#copy running-config scp:/ Address or name of remote host []: 10.10.10.
• For a file or directory on the NFS mounted file system, enter nfsmount:// followed by the mount point and the file path. NOTE: While deleting a file directory on a remote NFS file system, it is mandatory to specify the mount-point that indicates the working directory on the NFS file system. You cannot delete the root directory of the remote NFS file system. • no-confirm For a file or directory on an external USB drive, enter usbflash:// followed by the filename or directory name.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Added support for NFS mount. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 7.8.1.
Usage Information Include the colon (:) when entering this command. This command checks the specified flash memory for errors. If errors are found, the command recommends that you format the flash. CAUTION: If you elect to format the flash, all files – including the startup configuration file – are lost. If you do decide to format the specified flash, consider saving the running configuration as the startup configuration after formatting the flash (use the write memory command or copy run start command).
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S-Series. Example Dell#mount nfs nfstest nfs-mount-point usrname pwd Related Commands cd – changes the working directory. rmdir Removes a directory from the NFS mounted file system.
nfsmount:// / filepath Enter the keyword nfsmount: and specify the location of the image file in the format //
HTTP Copy via CLI Copy one file to another location. Dell Networking OS supports IPv4 and IPv6 addressing for FTP, TFTP, and SCP (in the hostip field). This feature is supported on S4810 platform. Syntax copy http://10.16.206.77/sample_file flash://sample_filecopy flash:// sample_file http://10.16.206.77/sample_file You can copy from the server to the switch and vice-versa. Parameters copy http: flash: Address or name of remote host []: 10.16.206.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. Added support for NFS mount. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Usage Information Version Description 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module. Restoring factory defaults deletes the existing startup configuration and all persistent settings (stacking, fan-out, and so forth). When restoring all units in a stack, all the units in the stack are placed into stand-alone mode.
-- Restore status -Unit Nvram Config -----------------------0 Success Success 1 Success Success 2 Success Success 3 Not present 4 Not present 5 Not present Power-cycling the unit(s). Dell# Example (single stack) Dell#restore factory-defaults stack-unit 0 clear-all ************************************************************** * Warning - Restoring factory defaults will delete the existing * * startup-config and all persistent settings (stacking, fanout, etc.
show boot system Displays information about boot images currently configured on the system. Syntax show boot system {stack-unit | all} Parameters all Enter the keyword all to display the boot image information for all stack units. stack-unit Enter the keyword stack-unit followed by a number to display boot image information for a stack-unit. The S4810 range is from 0 to 11. Defaults none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.4 Output expanded to display current reload mode (normal or Jumpstart). 8.3.11.1 Introduced on the Z9000.
Example Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series 7.5.1.0 Introduced on the C-Series E-Series Original command Dell#show file-systems Size(b) Free(b) Feature Type Flags Prefixes 63938560 51646464 dosFs2.0 MMC rw flash: 63938560 18092032 dosFs1.
• For a file on the USB port, enter usbflash://filepath. Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
show running-config Display the current configuration and display changes from the default values. Syntax show running-config [entity] [configured] [status] [compressed] Parameters entity (OPTIONAL) To display that entity’s current (non-default) configuration, enter one of the following keywords: NOTE: If you did not configure anything that entity, nothing displays and the prompt returns.
isis for the current ISIS configuration line for the current line configuration lldp for the current LLDP configuration load-balance for the current port-channel load-balance configuration logging for the current logging configuration mac for the current MAC ACL configuration mac-addresstable for the current MAC configuration managementeis for the current management EIS configuration managementroute for the current Management port forwarding configuration mld for the current MLD configura
snmp for the current SNMP configuration spanning-tree for the current spanning tree configuration static for the current static route configuration status for the file status information tacacs+ for the current TACACS+ configuration tftp for the current TFTP configuration trace-group for the current trace-group configuration trace-list for the current trace-list configuration uplink-stategroup for the uplink state group configuration users for the current users configuration vlt for the
Version Description 6.5.4.0 Added the status option. Example Dell# show running-config Current Configuration ... ! Version 9-0(2-0) ! Last configuration change at Thu Apr 18 10:18:39 2013 by admin ! Startup-config last updated at Thu Apr 18 10:18:40 2013 by admin ! boot system stack-unit 0 primary system: A: boot system stack-unit 0 secondary tftp://10.16.127.35/Dell-SI-9-0-2-0.bin boot system stack-unit 0 default system: A: boot system gateway 10.16.132.
Version Description 7.6.1.0 Introduced on S-Series 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Expanded to include the last configuration change, start-up last updated (date and time), and who made the change. Example Dell#show startup-config ! Version 9-0(2-0) ! Last configuration change at Thu Apr 18 10:18:39 2013 by admin ! Startup-config last updated at Thu Apr 18 10:18:40 2013 by admin ! boot system stack-unit 0 primary system: A: boot system stack-unit 0 secondary tftp://10.16.127.
Example (S-Series) Lines Beginning With Description Dell Operating... OS version number Dell Application... Software version Copyright (c)... Copyright information Build Time... Software build’s date stamp Build Path... Location of the software build files loaded on the system Dell Networking OS uptime is... Amount of time the system has been up System image... Image file name System Type: S4810, S4820T, Z9000, S6000 Control Processor:...
Copyright (c) 1999-2014 by Dell Inc. All Rights Reserved. Build Time: Tue Mar 18 10:32:02 PDT 2014 Build Path: /work.local/build/buildSpaces/build01/E9-4-0/SW/SRCC Dell Networking OS uptime is 1 day(s), 0 hour(s), 19 minute(s) System image file is "DT-MAA-S6000-16-PI" System Type: S6000 Control Processor: Intel Centerton with 3203911680 bytes of memory, core(s) 2. 16G bytes of boot flash memory. 1 32-port TE/FG (SI) 32 Forty GigabitEthernet/IEEE 802.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.0(0.0) Added support for IPv6 for the file-url parameter. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. Added support for the SSD on the Z9000 only. 8.3.7.0 Introduced on the S4810. 7.7.1.
4 Control and Monitoring This chapter contains the commands to configure and monitor the system, including Telnet, file transfer protocol (FTP), and trivial file transfer protocol (TFTP). NOTE: Starting in version 8.3.10.0, the enable xfp-power-updates command was deprecated for the S4810. This command replaces the enable optic-info-update interval command to update information on temperature and power monitoring in the simple network management protocol (SNMP) management information base (MIB).
banner exec Configure a message that is displayed when your enter EXEC mode. Syntax banner exec c line c To delete a banner, use the no banner exec command. Parameters c Enter the keywords banner exec, then enter a character delineator, represented here by the letter c. Press ENTER. line Enter a text string for your banner message ending the message with your delineator. In the following example, the delineator is a percent character (%); the banner message is “testing, testing”.
Press RETURN to get started. 4d21h6m: %RPM0-P:CP %SEC-5-LOGIN_SUCCESS: Login successful for user on line console This is the banner Dell> Related Commands line — enables and configures the console and virtual terminal lines to the system. banner login Set a banner to display when logging on to the system. Syntax banner login {keyboard-interactive | no keyboard-interactive} [c line c] Enter no banner login to delete the banner text.
Usage Information After entering the banner login command, type one or more spaces and a delineator character. Enter the banner text then the second delineator character. When the user is connected to the router, if a message of the day banner is configured, it displays first. If no message of the day banner is configured, the login banner and prompt appear. After the user has logged in, the banner EXEC (if configured) displays.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command Usage Information After entering the banner login command, type one or more spaces and a delineator character.
Enter 4 or 8 for the number of OpenFlow FP blocks. • 4: Creates 242 entries for use by the OpenFlow controller (256 total entries minus the 14 entries reserved for internal functionality) • 8: Creates 498 entries for use by the OpenFlow controller (512 total entries minus the 14 entries reserved for internal functionality) Using the fcoe parameter, enter the number of FP groups to be allocated for FCoE transit. Enter 1 – 6; maximum six groups.
cam-acl-vlan Specify the number of VFP blocks allocated to OpenFlow. Syntax cam-acl-vlan vlanopenflow {0|1} Defaults Disabled. Parameters vlanopenflow Enter the number 1 to allocate VFP blocks and enable OpenFlow. (Default) Enter the number 0 to disable OpenFlow. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command. configure Enter CONFIGURATION mode from EXEC Privilege mode.
disable Return to EXEC mode. Syntax disable [level] Parameters level (OPTIONAL) Enter a number for a privilege level of the Dell Networking OS. The range is from 0 to 15. The default is 1. Defaults 1 Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Usage Information Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series.
Usage Information Version Description 9.5(0.0) Added support for roles on the Z9000, S6000, S4820T, S4810, and MXL. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command.
Usage Information Version Description 8.3.11.4 Replacement command for the Z9000. Replaces the enable xfp-powerupdates command 8.3.10.0 Replacement command for the S4810 only. Replaces the enable xfp-powerupdates command. To enable polling and to configure the polling frequency, use this command. enable xfp-power-updates Enable 10–gigabit small form-factor pluggable (XFP) power updates for SNMP.
end Return to EXEC Privilege mode from other command modes (for example, CONFIGURATION or ROUTER OSPF modes). Syntax end Command Modes Command History • CONFIGURATION • SPANNING TREE • MULTIPLE SPANNING TREE • LINE • INTERFACE • TRACE-LIST • VRRP • ACCESS-LIST • PREFIX-LIST • AS-PATH ACL • COMMUNITY-LIST • ROUTER OSPF • ROUTER RIP • ROUTER ISIS • ROUTER BGP This guide is platform-specific.
To return to default settings, use the no exec-timeout command. Parameters minutes Enter the number of minutes of inactivity on the system before disconnecting the current session. The range is from 0 to 35791. The default is 10 minutes for the console line and 30 minutes for the VTY line. seconds (OPTIONAL) Enter the number of seconds. The range is from 0 to 2147483. The default is 0 seconds.
Command History • MAC ACCESS LIST • ACCESS-LIST • AS-PATH ACL • COMMUNITY-LIST • PREFIX-LIST • ROUTER OSPF • ROUTER RIP • ROUTER ISIS • ROUTER BGP This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.
Usage Information Version Description E-Series Original command. The hostname is used in the prompt. ip http source-interface Specify an interface as the source interface for HTTP connections. This feature is supported on S4810 platform. Syntax ip http source-interface interface To delete an interface, use theno ip http source-interface interface command.
ip ftp password Specify a password for outgoing FTP connections. Syntax ip ftp password [encryption-type] password To remove a password and return to the default setting, use the no ip ftp password [password] command. Parameters encryption-type password (OPTIONAL) Enter one of the following numbers: • 0 (zero) for an unecrypted (clear text) password • 7 (seven) for a hidden text password Enter a string up to 40 characters as the password. Defaults Not configured.
ip ftp source-interface Specify an interface’s IP address as the source IP address for FTP connections. Syntax ip ftp source-interface interface To delete an interface, use the no ip ftp source-interface interface command. Parameters interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
To return to anonymous FTP connections, use the no ip ftp username [username] command. Parameters username Enter a text string as the user name up to 40 characters long. Defaults No user name is configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.4(0.0) Introduced on the S-Series and Z9000. Use this command to make the FTP clients VRF-aware. The VRF name that you specify is used by the FTP client to reach the FTP server. If no VRF name is specified, then the default VRF is used. ip telnet server enable Enable the Telnet server on the switch.
To undo the TELNET server configuration, use the no ip telnet server [vrf vrf-name] command. Parameters vrf management Enter the keyword vrf followed by the keyword management to specify a management VRF that is used by the TELNET server. vrf vrf-name Enter the keyword vrf and then the name of the VRF to specify the VRF that is used by the TELNET server. Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific.
• For a tunnel interface, enter the keyword tunnel. Defaults The IP address on the system that is closest to the Telnet address is used in the outgoing packets. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.
The following is a list of the FTOS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.4.(0.0) Introduced on the S-Series and Z9000. Usage Information If you configure a TELNET client to use a specific VRF, then you need not explicitly specify the same VRF during the TELNET client sessions corresponding to that VRF. Example Dell(conf)#ip telnet vrf vrf1 Dell(conf)#do telnet 10.10.10.
Version Description 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.2.1.0 Increased number of VLANs on ExaScale to 4094 (was 2094). 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command ip tftp vrf Configures an TFTP client with a VRF that is used to connect to the TFTP server. Syntax ip tftp [vrf vrf-name] To undo the TFTP client configuration, use the no ip tftp [vrf vrf-name] command.
line Enable and configure console and virtual terminal lines to the system. This command accesses LINE mode, where you can set the access conditions for the designated line. Syntax Parameters line {aux 0 |console 0 | vty number [end-number]} aux 0 Enter the keyword aux 0 to configure the auxiliary terminal connection. console 0 Enter the keyword console 0 to configure the console port. The console option for the S-Series is <0-0>.
login concurrent-session Configures the limit of concurrent sessions for all users on console and virtual terminal lines. Syntax login concurrent-session {limit number-of-sessions | clear—line enable} no login concurrent-session {limit number-of-sessions | clear—line enable} Parameters limit number-ofsessions Sets the number of concurrent sessions that any user can have on console and virtual terminal lines. The range is from 1 to 12 (10 VTY lines, one console, and one AUX line).
Login: admin Password: Current sessions for user admin: Line Location 2 vty 0 10.14.1.97 3 vty 1 10.14.1.97 Clear existing session? [line number/Enter to cancel]: When you try to create more than the permitted number of sessions, the following message appears, prompting you to close one of your existing sessions. Close any of your existing sessions to log in to the system. $ telnet 10.11.178.14 Trying 10.11.178.14... Connected to 10.11.178.14. Escape character is '^]'.
Usage Information Version Description 9.8(0.0) Introduced on the S4810, S4820, S5000, S6000, S6000-ON, and Z9500. Only the system and security administrators can configure login activity tracking and view the login activity details of other users. If you enable user login statistics, the system displays the last successful login details of the current user and the details of any failed login attempts by others.
motd-banner Enable a message of the day (MOTD) banner to appear when you log in to the system. Syntax motd-banner To disable the MOTD banner, use the no motd-banner command. Defaults Enabled on all lines. Command Modes LINE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
count Enter the number of echo packets to be sent. The default is 5. • number: from 1 to 2147483647 • continuous: transmit echo request continuously datagram size Enter the ICMP datagram size. The range is from 36 to 15360 bytes. The default is 100. timeout Enter the interval to wait for an echo reply before timing out. The range is from 0 to 3600 seconds. The default is 2 seconds. source Enter the IPv4 or IPv6 source ip address or the source interface.
Defaults Command Modes Command History • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. none • EXEC • EXEC Privilege This guide is platform-specific.
Example (IPv4) Symbol Description . Each period indicates the network server timed out while waiting for a reply. U A destination unreachable error PDU was received. Q Source quench (destination too busy). M Could not fragment. ? Unknown packet type. & Packet lifetime exceeded. Dell#ping 172.31.1.255 Type Ctrl-C to abort. Sending 5, 100-byte ICMP Echos to 172.31.1.255, timeout is 2 seconds: Reply to request 1 from 172.31.1.208 0 ms Reply to request 1 from 172.31.1.
Usage Information Version Description 9.0.0.0 Introduced on the Z9000. 9.1(0.0) Added ‘conditional’ parameter. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command. If there is a change in the configuration, FTOS prompts you to save the new configuration. Or you can save your running configuration with the copy running-config command.
Usage Information Version Description 7.5.1.0 Introduced on the C-Series. 6.5.1.0 Introduced on the E-Series. Messages can contain an unlimited number of lines; however, each line is limited to 255 characters. To move to the next line, use . To send the message use CTR-Z; to abort a message, use CTR-C. service timestamps To debug and log messages, add time stamps. This command adds either the uptime or the current time and date.
Usage Information Version Description 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command. If you do not specify parameters and enter service timestamps, it appears as service timestamps debug uptime in the running-configuration. To view the current options set for the service timestamps command, use the show runningconfig command. show alarms View alarms currently active in the system.
---------------------------------------------RPM 0 PEM A failed or rmvd 7 hr, 37 min SFM 0 PEM A failed or rmvd 7 hr, 37 min SFM 1 PEM A failed or rmvd 7 hr, 37 min SFM 2 PEM A failed or rmvd 7 hr, 37 min SFM 3 PEM A failed or rmvd 7 hr, 37 min SFM 4 PEM A failed or rmvd 7 hr, 37 min SFM 5 PEM A failed or rmvd 7 hr, 37 min SFM 6 PEM A failed or rmvd 7 hr, 37 min SFM 7 PEM A failed or rmvd 7 hr, 36 min stack-unit 1 PEM A failed or rmvd 7 hr, 36 min stack-unit 4 PEM A failed or rmvd 7 hr, 36 min only 8 SFMs i
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.
[11/20 [11/20 [11/20 [11/20 Dell# 21:17:35]: 21:17:36]: 21:17:36]: 21:19:25]: CMD-(CLI):[line console 0]by default from console CMD-(CLI):[exec-timeout 0]by default from console CMD-(CLI):[exit]by default from console CMD-(CLI):[show command-history]by default from console show command-tree Display the entire CLI command tree, and optionally, display the utilization count for each command and its options.
Global configuration mode: aaa authentication enable command usage:1 WORD option usage: 1 default option usage: 0 enable option usage: 0 line option usage: 0 none option usage: 0 radius option usage: 1 tacacs+ option usage: 0 show cpu-traffic-stats View the CPU traffic statistics. Syntax Parameters show cpu-traffic-stats [port number | all | cp ] port number (OPTIONAL) Enter the port number to display traffic statistics on that port only. The range is from 1 to 1568.
NOTE: After debugging is complete, use the no debug cpu-traffic-stats command to shut off traffic statistics collection.
Port-channel 1-2 Port-channel 5 GigabitEthernet 4/0-3,5-6,10-11,20 GigabitEthernet 5/0-1,5-6,10-11,15,17,19,21 ICMP packet debugging is on for GigabitEthernet 5/0,2,4,6,8,10,12,14,16 Dell# show environment View S-Series and Z-Series system component status (for example, temperature or voltage). Syntax Parameters Command Modes Command History show environment [all | fan | stack-unit unit-id | pem ] all Enter the keyword all to view all components.
0 2 up up 7021 up 7021 Speed in RPM -- Power Supplies -Unit Bay Status Type FanStatus FanSpeed(rpm) --------------------------------------------------------------------------0 0 down UNKNOWN down 0 0 1 up AC up 6504 -- Unit Environment Status -Unit Status Temp Voltage TempStatus --------------------------------------------------------------------------* 0 online 36C ok 1 * Management Unit -- Thermal Sensor Readings (deg C) -Unit Sensor0 Sensor1 Sensor2 Sensor3 Sensor4 Sensor5 Sensor6 ----------------
Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.
Related Commands • show interfaces — displays the interface configuration. show login statistics Displays login statistics of users who have used the console or virtual terminal lines to log in to the system. Syntax show login statistics [[unsuccessful-attempts [user login-id] [time-period days]] | [all | user login-id]] Parameters all (Optional)Displays the login statistics of all users in the last 30 days or the custom defined time period.
NOTE: By default, these commands display the details for the last 30 days. If you set a customdefined time period for login statistics using the login statistics time-period days command, these commands display details only for that period. Example The following is sample output of the show login statistics command. Dell#show login statistics -----------------------------------------------------------------User: admin Last login time: Mon Feb 16 04:40:00 2015 Last login location: Line vty0 ( 10.14.1.
The following is sample output of the show login statistics unsuccessful-attempts user login-id command. Dell#show login statistics unsuccessful-attempts user admin There were 3 unsuccessful login attempt(s) for user admin in last 12 day(s). Related Commands login statistics — Enable and configure user login statistics on console and virtual terminal lines. login concurrent-session — Configures the limit of concurrent sessions for all users on console and virtual terminal lines.
Example (S4820T) Dell#show memory stack 0 Statistics On Unit 0 Processor =========================== Total(b) Used(b) Free(b) Lowest(b) Largest(b) 2147483648 4322398 2143161250 2142548382 2143161250 Dell# show memory View current memory usage on the switch.
show processes cpu Display CPU usage information based on processes running. Syntax show processes cpu [management-unit 1-99 [details] | stack-unit id | summary | [stack-unit id]] Parameters management-unit 1-99 [details] (OPTIONAL) Display processes running in the control processor. The 1-99 variable sets the number of tasks to display in order of the highest CPU usage in the past five (5) seconds. Add the keyword details to display all running processes (except sysdlp).
Dell#show processes cpu stack-unit 0 CPUID 5sec 1min 5min -------------------------------------------------CORE 0 13.17 11.53 0.00 CORE 2 9.38 12.16 0.00 Overall 11.28 11.84 0.00 CPU utilization of sysdlp for five seconds: 2%/0%; one minute: 3%; minutes: 1% PID Runtime(ms) Invoked uSecs 5Sec 1Min TTY Process 0xbb773000 5950 595 10000 1.00% 2.25% 0 tExcTask 0xbab2a000 4030 403 10000 1.00% 1.33% 0 frrpagt 0xbacf3000 10 1 10000 0.00% 0.00% 0 F10StkMgr 0xbad0c000 710 71 10000 0.00% 0.
0.00% 0 0.00% 0 0.00% 0 0.00% 0 0.08% 0 0.00% 0 0.00% 0 0.00% 0 53 52 51 50 49 48 47 46 60 portmirr 0 cfgDataSync 0 sysCompMgr 50 statMgr 1010 sflCp 30 snmp 0 dpi_cmow 0 dpi_taskcmo 6 10000 0.00% 0.00% 0 0 0.00% 0.00% 0 0 0.00% 0.00% 5 10000 0.00% 0.01% 101 10000 0.05% 0.07% 3 10000 0.00% 0.00% 0 0 0.00% 0.00% 0 0 0.00% 0.
Related Commands show hardware layer2 acl — displays Layer 2 ACL data for the selected stack member and stack member port-pipe. show hardware layer3 — displays Layer 3 ACL or QoS data for the selected stack member and stack member port-pipe. show hardware stack-unit — displays the data plane or management plane input and output statistics of the designated component of the designated stack member.
Usage Information Field Description Source QID /Tx Process Source Service Identifier Destination QID/Rx Process Destination Service Identifier Cur Len Current number of messages enqueued High Mark Highest number of packets in the queue at any time #of to / Timeout Timeout count #of Retr /Retries Number of retransmissions #msg Sent/Msg Sent/ Number of messages sent #msg Ackd/Ack Rcvd Number of messages acknowledged Retr /Available Retra Number of retries left Total/ Max Retra Number of
summary Command Modes Command History • EXEC • EXEC Privilege Enter the keyword summary for a brief summary of memory availability and usage on all stack members. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
For the S-Series, the output of the show memory command and this command differ based on which FTOS processes are counted. • In the show memory output, the memory size is equal to the size of the application processes. • In the output of this command, the memory size is equal to the size of the application processes plus the size of the system processes.
show software ifm Display interface management (IFM) data. Syntax Parameters show software ifm {clients [summary] | ifagt number | ifcb interface | stack-unit unit-ID | trace-flags} clients Enter the keyword clients to display IFM client information. summary (OPTIONAL) Enter the keyword summary to display brief information about IFM clients. ifagt number Enter the keyword ifagt then the number of an interface agent to display software pipe and IPC statistics.
Example Version Description 7.6.1.0 Introduced for the C-Series and S-Series.
Version Description 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.11.4 The brief parameter no longer displays the current Reload mode. To display Reload mode, use the show reload-type command. Modified the show system stack-unit command output to support Piece Part ID (PPID). 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 The Boot Flash field displays the code level for boot code 2.8.1.
Hardware Rev : 4.
Vendor Id Date Code Country Code Piece Part ID PPID Revision Service Tag Expr Svc Code Auto Reboot Burned In MAC No Of MACs : : : : : : : : : : DL 26092013 CN CN-08YWFG-28298-39Q-0015 A00 24N1VS1 463 414 838 5 disabled 90:b1:1c:f4:9b:79 3 -- Power Supplies -Unit Bay Status Type FanStatus FanSpeed(rpm) --------------------------------------------------------------------------0 0 down UNKNOWN down 0 0 1 up AC up 6600 -- Fan Status -Unit Bay TrayStatus Fan0 Speed Fan1 Speed --------------------------------
-----------------------------------------------------------------------------------1 1 up up 19275 up 19275 1 2 absent 1 3 up up 19275 up 18904 Speed in RPM Related Commands • show version – displays the Dell Networking OS version. • show hardware stack-unit – displays the data plane and management plane input and output statistics of a particular stack member.
Usage Information Without the page or stack-unit option, the command output is continuous. To interrupt the command output, use Ctrl-z. The save option works with other filtering commands. This allows you to save specific information of a show command. The save entry must always be the last option.
2 3 Example (S-Series) drwx d--- 1536 512 Jul 13 1996 02:38:06 +00:00 .. Nov 20 2007 15:46:44 +00:00 ADMIN_DIR Dell#show tech-support stack-unit 0 ----------------------------------- show version ------------------------------Dell Real Time Operating System Software Dell Operating System Version: 2.0 Dell Application Software Version: 9-4(0-168) Copyright (c) 1999-2014 by Dell Inc. All Rights Reserved. Build Time: Sun Mar 23 22:17:49 PDT 2014 Build Path: /work.
ssh-peer-stack-unit Open an SSH connection to the peer stack-unit. Syntax Parameters Defaults Command Modes Command History ssh-peer-stack-unit [-l username] -l username (OPTIONAL) Enter the keyword -l then your user name. The default is the user name associated with the terminal. Not configured. • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
source-interface Defaults (OPTIONAL) Enter the keywords /source-interface then the interface information to include the source interface. Enter the following keywords and slot/ port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383.
The source interface configured using this command has a higher precedence than the source interface configured using the ip telent source-interface command. If you do not configure a source interface using this command, then the TELNET client uses the source interface configured using the ip telent source-interface command. In case there is a mismatch between the VRF telnet source interface and the telent VRF, then an error is reported. Example Dell#telnet vrf vrf1 10.10.10.
Defaults 24 lines Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.
• Command History EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.
----------------------------------------------Tracing the route to 100::1, 64 hops max, 60 byte packets ----------------------------------------------Hops Hostname Probe1 Probe2 Probe3 1 100::1 000.000 ms 000.000 ms 000.000 ms FTOS#traceroute 3ffe:501:ffff:100:201:e8ff:fe00:4c8b Type Ctrl-C to abort.
virtual-ip Configure a virtual IP address for the active management interface. You can configure virtual addresses both for IPv4 and IPv6 independently. Syntax virtual-ip {ipv4-address | ipv6-address} To return to the default, use the no virtual-ip {ipv4-address | ipv6-address} command. Parameters ipv4-address Enter the IP address of the active management interface in a dotted decimal format (A.B.C.D.). ipv6-address Enter an IPv6 address of the active management interface, in the x:x:x:x::x format.
Parameters memory Enter the keyword memory to copy the current running configuration to the startup configuration file. This command is similar to the copy runningconfig startup-config command. compressed Enter the keyword compressed to write the operating configuration to the startup-config file in the compressed mode. terminal Enter the keyword terminal to copy the current running configuration to the terminal. This command is similar to the show running-config command.
5 802.1ag 802.1ag is available on the Dell Networking OS. ccm disable Disable continuity check message (CCM). Syntax ccm disable Enter no ccm disable to enable CCM. Defaults Disabled Command Modes ECFM DOMAIN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 8.3.19.
Version Description Version 8.3.19.0 Introduced on the S4820T. Version 8.3.11.1 Introduced on the Z9000. Version 8.3.7.0 Introduced on the S4810. Version 8.3.1.0 Introduced on the S-Series. clear ethernet cfm traceroute-cache Delete all link trace cache entries. Syntax clear ethernet cfm traceroute-cache Defaults none Command Modes ECFM DOMAIN Command History This guide is platform-specific.
Version Description 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the S-Series. disable Disable Ethernet CFM without stopping the CFM process. Syntax disable Defaults Disabled Command Modes ETHERNET CFM Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 8.3.19.
Version Description 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the S-Series. ethernet cfm Spawn the CFM process. No CFM configuration is allowed until the CFM process is spawned. Syntax ethernet cfm Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the S-Series. ethernet cfm mip Create a maintenance intermediate point (MIP).
Parameters mep-id Enter the MEP ID. The range is from 1 to 8191. Defaults none Command Modes ECFM DOMAIN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.
mep cross-check start-delay Configure the amount of time the system waits for a remote MEP to come up before the cross-check operation is started. Syntax Parameters mep cross-check start-delay number start-delay number Enter a start-delay in seconds. The range is from 3 to 100 seconds. Defaults 3 ccms Command Modes ETHERNET CFM Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the S-Series. show ethernet cfm domain Display maintenance domain information. Syntax show ethernet cfm domain [name | level | brief] Parameters name | level Enter the maintenance domain name or level. brief Enter the keyword brief to display a summary output.
show ethernet cfm maintenance-points local Display configured MEPs and MIPs. Syntax Parameters show ethernet cfm maintenance-points local [mep | mip] mep Enter the keyword mep to display configured MEPs. mip Enter the keyword mip to display configured MIPs. Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
domain [name | level] Enter the keyword domain then the domain name or domain level. expired Enter the keyword expired to view MEP entries that have expired due to connectivity failure. waiting Enter the keyword waiting to display MEP entries waiting for response. Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Version Description 8.3.1.0 Introduced on the S-Series. show ethernet cfm statistics Display MEP statistics. Syntax Parameters show ethernet cfm statistics [domain {name | level} vlan-id vlan-id mpid mpid] domain Enter the keyword domain to display statistics for a particular domain. name | level Enter the domain name or level. vlan-id vlan-id Enter the keyword vlan-id then a VLAN ID. mpid mpid Enter the keyword mpid then a maintenance point ID.
show ethernet cfm port-statistics Display CFM statistics by port. Syntax show ethernet cfm port-statistics [interface type slot/port[]] Parameters interface type Enter the keyword interface then the interface type. slot/port[] Enter the slot and port numbers for the port. Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Next Host Egress MAC Egress Action -------------------------------------------------------4 00:00:00:01:e8:53:4a:f8 00:01:e8:52:4a:f8 IngOK 00:00:00:01:e8:52:4a:f8 FWD Status RlyHit Terminal MEP service Create maintenance association. Syntax Parameters service name vlan vlan-id name Enter a maintenance association name. vlan vlan-id Enter the keyword vlan and then enter the VLAN ID. The range is from 1 to 4094.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the S-Series. traceroute cache size Set the size of the link trace cache. Syntax traceroute cache size entries Parameters entries Enter the number of entries the link trace cache can hold. The range is from 1 to 4095 entries. Defaults 100 entries Command Modes ETHERNET CFM Command History This guide is platform-specific.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the S-Series. 802.
6 802.1X An authentication server must authenticate a client connected to an 802.1X switch port. Until the authentication, only extensible authentication protocol over LAN (EAPOL) traffic is allowed through the port to which a client is connected. After authentication is successful, normal traffic passes through the port. The Dell Networking operating software supports remote authentication dial-in service (RADIUS) and active directory environments using 802.1X Port Authentication.
interface interface Restricts the debugging information to an interface. Defaults Disabled Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.4.1.0 Introduced on the C-Series and S-Series. If the host responds to 802.1X with an incorrect login/password, the login fails. The switch attempts to authenticate again until the maximum attempts configured is reached. If the authentication fails after all allowed attempts, the interface moves to the authentication failed VLAN.
dot1x auth-type mab-only To authenticate a device with MAC authentication bypass (MAB), only use the host MAC address. Syntax dot1x auth-type mab-only Defaults Disabled Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000.
dot1x guest-vlan Configure a guest VLAN for limited access users or for devices that are not 802.1X capable. Syntax dot1x guest-vlan vlan-id To disable the guest VLAN, use the no dot1x guest-vlan vlan-id command. Parameters vlan-id Enter the VLAN Identifier. The range is from 1 to 4094. Defaults Not configured. Command Modes CONFIGURATION (conf-if-interface-slot/port) Command History This guide is platform-specific.
dot1x host-mode Enable single-host or multi-host authentication. Syntax dot1x host-mode {single-host | multi-host | multi-auth} Parameters single-host Enable single-host authentication. multi-host Enable multi-host authentication. multi-auth Enable multi-supplicant authentication. Defaults single-host Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Defaults Disabled Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.
Version Description 8.3.11.1 Introduced on the Z9000. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. dot1x max-supplicants Restrict the number of supplicants that can be authenticated and permitted to access the network through the port. This configuration is only takes effect in Multi-auth mode. Syntax dot1x max-supplicants number Parameters number Enter the number of supplicants that can be authenticated on a single port in Multi-auth mode.
force-unauthorized Enter the keywords force-unauthorized to forcibly de-authorize a port. Defaults none Command Modes Auto Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.0.0.
Version Description 8.3.12.0 Introduced on the S4810. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. dot1x reauthentication Enable periodic reauthentication of the client. Syntax dot1x reauthentication [interval seconds] To disable periodic reauthentication, use the no dot1x reauthentication command. Parameters interval seconds (Optional) Enter the keyword interval then the interval time, in seconds, after which reauthentication is initiated.
Parameters number Enter the permitted number of re-authentications. The range is from 1 to 10. The default is 2. Defaults 2 Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.0.0.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. When you configure the dot1x server-timeout value, take into account the communication medium used to communicate with an authentication server and the number of RADIUS servers configured.
Version Description 8.3.11.1 Introduced on the Z9000. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. dot1x tx-period Configure the intervals at which EAPOL PDUs the Authenticator PAE transmits. Syntax dot1x tx-period seconds To return to the default, use the no dot1x tx-period command. Parameters seconds Enter the interval time, in seconds, that EAPOL PDUs are transmitted. The range is from 1 to 65535. The default is 30.
mac-address Defaults • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. (Optional) MAC address of an 802.1X-authenticated supplicant. none Command Modes Command History • EXEC • EXEC privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
802.1p CoS re-map table for Supplicant: 00:00:00:00:00:10 Dot1p 0 1 2 3 4 5 6 7 Dell# Remapped Dot1p 7 6 5 4 3 2 1 0 show dot1x interface Display the 802.1X configuration of an interface. Syntax Parameters show dot1x interface interface [mac-address mac-address] interface mac-address Defaults Command Modes Command History Enter one of the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
Usage Information If you enable 802.1X multi-supplicant authentication on a port, additional 802.1X configuration details (Port Authentication status, Untagged VLAN ID, Authentication PAE state, and Backend state) display for each supplicant, as shown in the following example. Example Dell#show dot1x interface tengigabitethernet 1/32 802.
Dell# show dot1x interface tengigabitethernet 1/32 mac-address 00:00:00:00:00:11 Supplicant Mac: 0 0 0 0 0 10 Lookup for Mac: 802.
00:00:00:00:00:11 Supplicant Mac: 0 0 0 0 0 10 Lookup for Mac: 802.
7 Access Control Lists (ACL) Access control lists (ACLs) are supported by the Dell Networking OS.
Command History • CONFIGURATION-EXTENDED-ACCESS-LIST • CONFIGURATION-MAC ACCESS LIST-STANDARD • CONFIGURATION-MAC ACCESS LIST-EXTENDED This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
• Command History CONFIGURATION-MAC ACCESS LIST-EXTENDED This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.1.
Defaults Not configured. Command Modes LINE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Added the ipv4 and ipv6 parameters to the command. Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.
Parameters access-list-name (OPTIONAL) Enter the name of a configured access-list, up to 140 characters. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
NOTE: When you specify a single VRF, use the name of the VRF instead of the VRF ID number. Use the VRF ID numbers only when you specify a range of VRFs. Defaults Not enabled. Command Modes INTERFACE/VRF MODE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
ip control-plane egress-filter Enable egress Layer 3 ACL lookup for IPv4 CPU traffic. Syntax ip control-plane egress-filter Defaults Not enabled. Command Modes EXEC Privilege Command History Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. show ip accounting access-list Display the IP access-lists created on the switch and the sequence of filters.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for the 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced. show ip accounting access-lists Description “Extended IP...
Command Modes Command History Example • For a VLAN interface, enter the keyword vlan followed by the slot/port number. • For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet followed by the slot/port information. • For a Port Channel interface, enter the keyword port-channel followed by a number. For the C-Series and S-Series, the range is 1 to 128. For the E-Series, the range is 1 to 255 for TeraScale and 1 to 512 for ExaScale.
deny To drop packets with a certain IP address, configure a filter. Syntax deny {source | any | host {ip-address}} [no-drop] To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no deny {source [mask] | any | host ip-address} command. source Enter the IP address in dotted decimal format of the network from which the packet was sent.
Usage Information Version Description 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added support for the non-contiguous mask and added the monitor option. 6.5.1.0 Expanded to include the optional QoS order priority for the ACL entry. The order option is relevant in the context of the Policy QoS feature only. For more information, refer to the Quality of Service chapter of the Dell Networking OS Configuration Guide.
Usage Information Version Description 7.4.1.0 Added support for the non-contiguous mask and added the monitor option. 6.5.1.0 Expanded to include the optional QoS order priority for the ACL entry. Dell Networking OS supports one ingress and one egress IP ACL per interface. Prior to Dell Networking OS version 7.8.1.0, names are up to 16 characters long. The number of entries allowed per ACL is hardware-dependent.
Defaults Not configured. Command Modes CONFIGURATION-STANDARD-ACCESS-LIST Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Added the no-drop parameter. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
host ip-address Enter the keyword host then the IP address to specify a host IP address or hostname. count (OPTIONAL) Enter the keyword count to count packets the filter processes. bytes (OPTIONAL) Enter the keyword bytes to count bytes the filter processes. dscp (OPTIONAL) Enter the keyword dcsp to match to the IP DCSCP values. order (OPTIONAL) Enter the keyword order to specify the QoS order for the ACL entry.
• Related Commands If you configure sequence-number, the sequence-number is used as a tie breaker for rules with the same order. deny — configures a filter to drop packets. permit — configures a filter to forward packets. Extended IP ACL Commands When an ACL is created without any rule and then applied to an interface, ACL behavior reflects an implicit permit. The following commands configure extended IP ACLs, which in addition to the IP address, also examine the packet’s protocol type.
order (OPTIONAL) Enter the keyword order to specify the QoS priority for the ACL entry. The range is from 0 to 254 (where 0 is the highest priority and 254 is the lowest; lower-order numbers have a higher priority). If you do not use the keyword order, the ACLs have the lowest order by default (255). monitor (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface.
The C-Series and S-Series cannot count both packets and bytes, when you enter the count byte options, only bytes are incremented. NOTE: When you configure ACL logging and byte counters simultaneously, byte counters may display an incorrect value. Configure packet counters with logging instead. Related Commands deny tcp — assigns a filter to deny TCP packets. deny udp — assigns a filter to deny UDP packets. ip access-list extended — creates an extended ACL.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Added the no-drop parameter. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Added the keyword dscp. 8.2.1.0 Allows ACL control of fragmented packets for IP (Layer 3) ACLs. 8.1.1.0 Introduced on the E-Series ExaScale. 7.4.1.
operator port port • psh: push function • rst: reset the connection • syn: synchronize sequence numbers • urg: urgent field (OPTIONAL) Enter one of the following logical operand: • eq = equal to • neq = not equal to • gt = greater than • lt = less than • range = inclusive range of ports (you must specify two ports for the port command) Enter the application layer port number. Enter two port numbers if using the range logical operand. The range is from 0 to 65535.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Added the keyword dscp. 8.2.1.0 Allows ACL control of fragmented packets for IP (Layer 3) ACLs. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added support for non-contiguous mask and added the monitor option. Deprecated the keyword established. 6.5.1.
Related Commands deny — assigns a filter to deny IP traffic. deny udp — assigns a filter to deny UDP traffic. deny udp To drop user datagram protocol (UDP) packets meeting the filter criteria, configure a filter.
no-drop Enter the keywords no-drop to match only the forwarded packets. Defaults Not configured. Command Modes CONFIGURATION-EXTENDED-ACCESS-LIST Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Added the no-drop parameter. 9.7(0.
4 5 6 7 8 0001100000000000 0001110000000000 0001111000000000 0001111100000000 0001111101000000 1111110000000000 1111111000000000 1111111100000000 1111111111000000 1111111111111111 6144 7168 7680 7936 8000 7167 7679 7935 7999 8000 1024 512 256 64 1 Total Ports: 4001 Example An ACL rule with a TCP port lt 1023 uses only one entry in the CAM.
Usage Information The number of entries allowed per ACL is hardware-dependent. For detailed specification about entries allowed per ACL, refer to your line card documentation. Prior to 7.8.1.0, names are up to 16 characters long. Example Dell(conf)#ip access-list extended TESTListEXTEND Dell(config-ext-nacl)# Related Commands ip access-list standard — configures a standard IP access list. show config — displays the current configuration.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Added the no-drop parameter. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Add the DSCP value for ACL matching. 8.2.1.0 Allows ACL control of fragmented packets for IP (Layer 3) ACLs. 8.1.1.
any Enter the keyword any to specify that all routes are subject to the filter. host ip-address Enter the keyword host then the IP address to specify a host IP address. bit Enter a flag or combination of bits: • ack: acknowledgement field • fin: finish (no more data from the user) • psh: push function • rst: reset the connection • syn: synchronize sequence numbers • urg: urgent field dscp Enter the keyword dscp to deny a packet based on the DSCP value. The range is from 0 to 63.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Added the no-drop parameter. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Total Ports: 4001 Example An ACL rule with a TCP port lt 1023 uses only one entry in the CAM. Rule# Data Mask From To 1 0000000000000000 1111110000000000 0 #Covered 1023 1024 Total Ports: 1024 Related Commands ip access-list extended — creates an extended ACL. permit — assigns a permit filter for IP packets. permit udp — assigns a permit filter for UDP packets. permit udp To pass UDP packets meeting the filter criteria, configure a filter.
count (OPTIONAL) Enter the keyword count to count packets processed by the filter. byte (OPTIONAL) Enter the keyword byte to count bytes processed by the filter. order (OPTIONAL) Enter the keyword order to specify the QoS priority for the ACL entry. The range is from 0 to 254 (where 0 is the highest priority and 254 is the lowest; lower-order numbers have a higher priority). If you do not use the keyword order, the ACLs have the lowest order by default (255).
Most ACL rules require one entry in the CAM. However, rules with TCP and UDP port operators (for example, gt, lt, or range) may require more than one entry. The range of ports is configured in the CAM based on bit mask boundaries; the space required depends on exactly what ports are included in the range. Example An ACL rule with a TCP port range of 4000–8000 uses eight entries in the CAM.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale (IPv4). 7.8.1.0 Increased the name string to accept up to 140 characters. Prior to 7.8.1.0, names were up to 16 characters long. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.
operator port port (OPTIONAL) Enter one of the following logical operands: • eq = equal to • neq = not equal to • gt = greater than • lt = less than • range = inclusive range of ports (you must specify two ports for the port parameter.) (OPTIONAL) Enter the application layer port number. Enter two port numbers if you are using the range logical operand. The range is from 0 to 65535.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Add the DSCP value for ACL matching. 8.2.1.0 Allows ACL control of fragmented packets for IP (Layer 3) ACLs. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.
Common MAC Access List Commands The following commands are available within both MAC ACL modes (Standard and Extended) and do not have mode-specific options. These commands allow you to clear, display, and assign MAC ACL configurations. The platform supports both Ingress and Egress MAC ACLs. The MAC ACL can be applied on Physical, Port-channel and VLAN interfaces. As per the specified rules in the ACL, the traffic on the interface/ VLAN members or Port-channel members will be permitted or denied.
NOTE: This option is available only with the keywordin option. in Enter the keyword in to configure the ACL to filter incoming traffic. out Enter the keyword out to configure the ACL to filter outgoing traffic. NOTE: The option is not available on the S-Series. NOTE: 1. If the MAC ACL is applied on VLAN, none of the VLAN members should have an access list applied for that VLAN. 2.
show mac access-lists Display all of the Layer 2 ACLs configured in the system, whether or not they are applied to an interface, and the count of matches/ mismatches against each ACL entry displayed. Syntax Parameters show mac access-lists [access-list-name] [interface interface] [in | out] access-list-name Enter the name of a configured MAC ACL, up to 140 characters.
in | out Command Modes Command History • EXEC • EXEC Privilege • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Identify whether ACL is applied on ingress or egress side. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
deny To drop packets with a the MAC address specified, configure a filter. Syntax deny {any | mac-source-address [mac-source-address-mask]} [count [byte]] [log] [monitor] To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no deny {any | mac-source-address mac-source-address-mask} command. any Enter the keyword any to specify that all routes are subject to the filter.
Usage Information When you use the log option, the CP processor logs detail the packets that match. Depending on how many packets match the log entry and at what rate, the CP may become busy as it has to log these packets’ details. NOTE: When you configure ACL logging and byte counters simultaneously, byte counters may display an incorrect value. Configure packet counters with logging instead. Related Commands permit — configures a MAC address filter to pass packets.
NOTE: Ingress ACLs are supported on C-Series and S-Series platforms only. Example Dell(conf)#mac-access-list access-list standard TestMAC Dell(config-std-macl)#permit 00:00:00:00:00:00 00:00:00:00:ff:ff count Dell(config-std-macl)#deny any count permit To forward packets from a specific source MAC address, configure a filter.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. When you use the log option, the CP processor logs details about the packets that match. Depending on how many packets match the log entry and at what rate, the CP may become busy as it has to log these packets’ details.
NOTE: For more information, refer to the “Flow-based Monitoring” section in the Port Monitoring chapter of the Dell Networking OS Configuration Guide. no-drop Enter the keywords no-drop to match only the forwarded packets. Defaults Not configured Command Modes CONFIGURATION-MAC ACCESS LIST-STANDARD Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
NOTE: For more information, also refer to the Commands Common to all ACL Types and Common MAC Access List Commands sections. deny To drop packets that match the filter criteria, configure a filter.
Monitoring” section in the Port Monitoring chapter of the Dell Networking OS Configuration Guide. Defaults Not configured. Command Modes CONFIGURATION-MAC ACCESS LIST-EXTENDED Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.10.0 Introduced on the S4810. 8.1.
permit To pass packets matching the criteria specified, configure a filter. Syntax permit {any | host mac-address | mac-source-address mac-source-addressmask} {any | host mac-address | mac-destination-address mac-destinationaddress-mask} [ethertype operator] [count [byte]] | [log] [monitor] To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command if you know the filter’s sequence number.
NOTE: For more information, refer to the Flow-based Monitoring section in the Port Monitoring chapter of the Dell Networking OS Configuration Guide. Defaults Not configured. Command Modes CONFIGURATION-MAC ACCESS LIST-EXTENDED Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Parameters prefix-name (OPTIONAL) Enter the name of the configured prefix list to clear only counters for that prefix list, up to 140 characters long. Defaults Clears “hit” counters for all prefix lists unless a prefix list is specified. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series.
Version Description 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. Usage Information Prefix lists redistribute OSPF and RIP routes meeting specific criteria. Related Commands show ip route list — displays IP routes in an IP prefix list. show ip prefix-list summary — displays a summary of the configured prefix lists. seq To a deny or permit filter in a prefix list while configuring the filter, assign a sequence number.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.3.1.0 Added the bit mask option. If you do not use the ge or le options, only packets with an exact match to the prefix are filtered. show config Display the current PREFIX-LIST configurations.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.
Example Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Increased the name string to accept up to 140 characters. Prior to 7.8.1.0, names are up to 16 characters long. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series.
Usage Information Version Description 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. The continue feature allows movement from one route-map entry to a specific route-map entry (the sequence number). If you do not specify the sequence number, the continue feature simply moves to the next sequence number (also known as an implied continue).
Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.
Related Commands Version Description 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. set as-path — adds information to the BGP AS_PATH attribute. match community To match routes that have a certain COMMUNITY attribute in their BGP path, configure a filter. Syntax match community community-list-name [exact] To delete a community match filter, use the no match community command. Parameters community-listname Enter the name of a configured community list.
Parameters interface Enter the following keywords and slot/port or number information: • . • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128.
match ip address To match routes based on IP addresses specified in an access list, configure a filter. Syntax match ip address prefix-list-name To delete a match, use the no match ip address prefix-list-name command. Parameters prefix-list-name Enter the name of configured prefix list, up to 140 characters. Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific.
To delete a match, use the no match ip next-hop {prefix-list prefix-list-name} command. Parameters prefix-list prefix-listname Enter the keywords prefix-list and then enter the name of configured prefix list, up 10 140 characters. Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Parameters prefix-list prefix-listname Enter the keywords prefix-list and then enter the name of configured prefix list, up to 140 characters. Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.
Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. pre-6.1.1.0 Introduced on the E-Series. match route-type To match routes based on the how the route is defined, configure a filter.
Related Commands Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. match interface — redistributes routes that match the next-hop interface. match ip address — redistributes routes that match an IP address. match ip next-hop — redistributes routes that match the next-hop IP address. match ip route-source — redistributes routes that match routes advertised by other routers.
Related Commands match interface — redistributes routes that match the next-hop interface. match ip address — redistributes routes that match an IP address. match ip next-hop — redistributes routes that match the next-hop IP address. match ip route-source — redistributes routes that match routes advertised by other routers. match metric — redistributes routes that match a specific metric. match route-type — redistributes routes that match a route type.
Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Usage Information Use caution when you delete route maps because if you do not specify a sequence number, all route maps with the same map-name are deleted when you use the no route-map map-name command. Example Dell(conf)#route-map dempsey Dell(config-route-map)# Related Commands show config — displays the current configuration.
Related Commands match as-path — redistributes routes that match an AS-PATH attribute. set automatic-tag To automatically compute the tag value of the route, configure a filter. Syntax set automatic-tag To return to the default, enter no set automatic-tag. Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
All routes with the NO_EXPORT_SUBCONFED (0xFFFFFF03) community attribute must not be advertised to external BGP peers. no-advertise Enter the keywords no-advertise to drop all routes containing the well-known community attribute of NO_ADVERTISE. All routes with the NO_ADVERTISE (0xFFFFFF02) community attribute must not be advertised to other BGP peers. no-export Enter the keywords no-export to drop all routes containing the well-known community attribute of NO_EXPORT.
To remove a set level condition, use the no set level {backbone | level-1 | level-1-2 | level-2 | stub-area} command. Parameters backbone Enter the keyword backbone to redistribute matched routes to the OSPF backbone area (area 0.0.0.0). level-1 Enter the keyword level-1 to redistribute matched routes to IS-IS Level 1. level-1-2 Enter the keyword level-1-2 to redistribute matched routes to IS-IS Level 1 and Level 2. level-2 Enter the keyword level-2 to redistribute matched routes to IS-IS Level 2.
Parameters value Enter a number as the LOCAL_PREF attribute value. The range is from 0 to 4294967295. Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.
The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series.
Related Commands Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Implemented the keyword internal. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. set automatic-tag — computes the tag value of the route. set level — specifies the OSPF area for route redistribution.
Usage Information Version Description pre-6.1.1.0 Introduced on the E-Series. If you configure the set next-hop command, its configuration takes precedence over the neighbor next-hop-self command in the ROUTER BGP mode. If you configure the set next-hop command with the interface’s IP address (either Loopback or physical), the software declares the route unreachable. Related Commands match ip next-hop — redistributes routes that match the next-hop IP address.
set tag To specify a tag for redistributed routes, configure a filter. Syntax set tag tag-value To delete a setting, use the no set tag command. Parameters tag-value Enter a number as the tag. The range is from zero (0) to 4294967295. Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
When there are multiple routes to the same destination, the routes with a higher weight are preferred. Defaults router-originated = 32768; all other routes = 0 Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.
Example Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Dell(conf-nprefixl)#show config ! ip prefix-list PL_OSPF_to_RIP seq 5 permit 1.1.1.0/24 seq 10 deny 2.1.0.0/16 ge 23 seq 25 permit 192.0.0.0 bitmask 192.0.0.0 show route-map Display the current route map configurations.
Related Commands route-map — configures a route map. AS-Path Commands The following commands configure AS-Path ACLs. ip as-path access-list Enter AS-PATH ACL mode and configure an access control list based on the BGP AS_PATH attribute. Syntax ip as-path access-list as-path-name Parameters as-path-name Enter the access-list name, up to 140 characters. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. pre-Version 6.1.1.0 Introduced on the E-Series.
Example Dell(conf)#ip community-list TestComList Dell(config-community-list)# show ip community-lists Display configured IP community lists in alphabetic order. Syntax show ip community-lists [name] Parameters Command Modes Command History name • EXEC • EXEC Privilege (OPTIONAL) Enter the name of the standard or extended IP community list, up to 140 characters. This guide is platform-specific.
Defaults threshold-in msgs count (OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to indicate the maximum number of ACL logs that can be generated, exceeding which the generation of ACL logs is terminated. with the seq, permit, or deny commands. The threshold range is from 1 to 100. interval minutes (OPTIONAL) Enter the keyword interval followed by the time period in minutes at which ACL logs must be generated. The time interval range is from 1 to 10 minutes.
deny (for Extended IP ACLs) Configure a filter that drops IP packets meeting the filter criteria. Syntax deny {ip | ip-protocol-number} {source mask | any | host ip-address} {destination mask | any | host ip-address} [count [byte]] [dscp value] [order] [monitor] [fragments] [log [interval minutes] [threshold-in-msgs [count]] [monitor] To remove this filter, you have two choices: Parameters Defaults • Use the no seq sequence-number command if you know the filter’s sequence number.
You can activate flow-based monitoring for a monitoring session by entering the flow-based enable command in the Monitor Session mode. When you enable this capability, traffic with particular flows that are traversing through the ingress and egress interfaces are examined and, appropriate ACLs can be applied in both the ingress and egress direction. Flow-based monitoring conserves bandwidth by monitoring only specified traffic instead all traffic on the interface.
Usage Information Version Description 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero.
monitor Defaults (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface. By default, 10 ACL logs are generated if you do not specify the threshold explicitly. The default frequency at which ACL logs are generated is five minutes. By default, flow-based monitoring is not enabled.
[count [byte]] [order] [fragments] [log [interval minutes] [threshold-inmsgs [count]] To remove this filter, you have two choices: Parameters Defaults • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no deny udp {source mask | any | host ip-address} {destination mask | any | host ip-address} command. log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages.
• Parameters Defaults Use the no deny arp {destination-mac-address mac-address-mask | any} vlan vlan-id {ip-address | any | opcode code-number} command. log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages. threshold-in msgs count (OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to indicate the maximum number of ACL logs that can be generated, exceeding which the generation of ACL logs is terminated with the seq, permit, or deny commands.
deny icmp (for Extended IP ACLs) To drop all or specific internet control message protocol (ICMP) messages, configure a filter. NOTE: Only the options that have been newly introduced in Release 9.3(0.0) and Release 9.4(0.0) are described here. For a complete description on all of the keywords and variables that are available with this command, refer the topic of this command discussed earlier in this guide.
traversing through the ingress and egress interfaces are examined and, appropriate ACLs can be applied in both the ingress and egress direction. Flow-based monitoring conserves bandwidth by monitoring only specified traffic instead all traffic on the interface. This feature is particularly useful when looking for malicious traffic. It is available for Layer 2 and Layer 3 ingress and egress traffic. You may specify traffic using standard or extended access-lists.
Usage Information Version Description 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero.
The default frequency at which ACL logs are generated is five minutes. By default, flow-based monitoring is not enabled. Command Modes Command History Usage Information CONFIGURATION-MAC ACCESS LIST-STANDARD Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms.
• Parameters Defaults Use the no deny {any | host mac-address | mac-source-address mac-sourceaddress-mask} {any | host mac-address | mac-destination-address macdestination-address-mask} command. log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages. threshold-in msgs count (OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to indicate the maximum number of ACL logs that can be generated, exceeding which the generation of ACL logs is terminated.
Related Commands permit — configures a MAC address filter to pass packets. seq — configures a MAC address filter with a specified sequence number. permit (for Standard IP ACLs) To permit packets from a specific source IP address to leave the switch, configure a filter.
If ACL logging is stopped because the configured threshold is exceeded, it is re-enabled after the logging interval period elapses. ACL logging is supported for standard and extended IPv4 ACLs, IPv6 ACLs, and MAC ACLs. You can configure ACL logging only on ACLs that are applied to ingress interfaces; you cannot enable logging for ACLs that are associated with egress interfaces.
Command Modes Command History Usage Information CONFIGURATION-EXTENDED-ACCESS-LIST Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped.
the generation of ACL logs is terminated. with the seq, permit, or deny commands. The threshold range is from 1 to 100. Defaults interval minutes (OPTIONAL) Enter the keyword interval followed by the time period in minutes at which ACL logs must be generated. The interval range is from 1 to 10 minutes. monitor (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface.
To remove this filter, you have two choices: Parameters Defaults • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no permit icmp {source mask | any | host ip-address} {destination mask | any | host ip-address} command. log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages.
permit udp (for Extended IP ACLs) To pass UDP packets meeting the filter criteria, configure a filter. Syntax permit udp {source mask | any | host ip-address} [operator port [port]] {destination mask | any | host ip-address} [dscp] [operator port [port]] [count [byte]] [order] [fragments] [log [interval minutes] [threshold-inmsgs [count]][monitor] To remove this filter, you have two choices: Parameters Defaults • Use the no seq sequence-number command if you know the filter’s sequence number.
You can activate flow-based monitoring for a monitoring session by entering the flow-based enable command in the Monitor Session mode. When you enable this capability, traffic with particular flows that are traversing through the ingress and egress interfaces are examined and, appropriate ACLs can be applied in both the ingress and egress direction. Flow-based monitoring conserves bandwidth by monitoring only specified traffic instead all traffic on the interface.
Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4(0.0) Added the support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.0) Added the support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped.
Defaults threshold-in msgs count (OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to indicate the maximum number of ACL logs that can be generated, exceeding which the generation of ACL logs is terminated with the seq, permit, or deny commands. The threshold range is from 1 to 100. interval minutes (OPTIONAL) Enter the keyword interval followed by the time period in minutes at which ACL logs must be generated. The interval range is from 1 to 10 minutes.
seq (for Standard MAC ACLs) To a deny or permit filter in a MAC access list while creating the filter, assign a sequence number. Syntax seq sequence-number {deny | permit} {any | mac-source-address [mac-sourceaddress-mask]} [count [byte]] [log [interval minutes] [threshold-in-msgs [count]] [monitor] To remove this filter, use the no seq sequence-number command. Parameters Defaults log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages.
standard or extended access-lists. This mechanism copies all incoming or outgoing packets on one port and forwards (mirrors) them to another port. The source port is the monitored port (MD) and the destination port is the monitoring port (MG). Related Commands deny — configures a filter to drop packets. permit — configures a filter to forward packets. permit tcp (for Extended IP ACLs) To pass TCP packets meeting the filter criteria, configure a filter.
Usage Information When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero. If ACL logging was stopped previously because the configured threshold is exceeded, it is re-enabled for this new interval.
monitor Defaults (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface. By default, 10 ACL logs are generated if you do not specify the threshold explicitly. The default frequency at which ACL logs are generated is 5 minutes. By default, flow-based monitoring is not enabled.
address mac-address-mask | any} [count [byte]] [order] [log [interval minutes] [threshold-in-msgs [count]] [monitor] To remove this filter, use the no seq sequence-number command. Parameters Defaults log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages. threshold-in msgs count (OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to indicate the maximum number of ACL logs that can be generated, exceeding which the generation of ACL logs is terminated.
forwards (mirrors) them to another port. The source port is the monitored port (MD) and the destination port is the monitoring port (MG). seq (for IP ACLs) Assign a sequence number to a deny or permit filter in an extended IP access list while creating the filter.
You can activate flow-based monitoring for a monitoring session by entering the flow-based enable command in the Monitor Session mode. When you enable this capability, traffic with particular flows that are traversing through the ingress and egress interfaces are examined and, appropriate ACLs can be applied in both the ingress and egress direction. Flow-based monitoring conserves bandwidth by monitoring only specified traffic instead all traffic on the interface.
Usage Information Version Description 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero.
monitor Defaults (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface. By default, 10 ACL logs are generated if you do not specify the threshold explicitly. The default frequency at which ACL logs are generated is five minutes. By default, flow-based monitoring is not enabled. Command Modes Command History Usage Information ACCESS-LIST Version Description 9.7(0.
Parameters Defaults • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no permit tcp {source address mask | any | host ipv6-address} {destination address | any | host ipv6-address} command. log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages.
Related Commands permit – assigns a permit filter for IP packets. permit icmp (for IPv6 ACLs) To allow all or specific internet control message protocol (ICMP) messages, configure a filter.
If ACL logging is stopped because the configured threshold is exceeded, it is re-enabled after the logging interval period elapses. ACL logging is supported for standard and extended IPv4 ACLs, IPv6 ACLs, and MAC ACLs. You can configure ACL logging only on ACLs that are applied to ingress interfaces; you cannot enable logging for ACLs that are associated with egress interfaces.
Command History Usage Information Version Description 9.8(0.0) Added the no-drop parameter. 9.7(0.0) Introduced on the S6000–ON. 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped.
Defaults interval minutes (OPTIONAL) Enter the keyword interval followed by the time period in minutes at which ACL logs must be generated. The threshold range is from 1 to 10 minutes. monitor (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface. By default, 10 ACL logs are generated if you do not specify the threshold explicitly.
port [port]] [count [byte]] [log [interval minutes] [threshold-in-msgs [count]] [monitor] To remove this filter, you have two choices: Parameters Defaults • Use the no seq sequence-number command syntax if you know the filter’s sequence number • Use the no deny tcp {source address mask | any | host ipv6-address} {destination address | any | host ipv6-address} command log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages.
standard or extended access-lists. This mechanism copies all incoming or outgoing packets on one port and forwards (mirrors) them to another port. The source port is the monitored port (MD) and the destination port is the monitoring port (MG). deny icmp (for Extended IPv6 ACLs) Configure a filter to drop all or specific ICMP messages. NOTE: Only the options that have been newly introduced in Release 9.3(0.0) and Release 9.4(0.0) are described here.
Usage Information When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero. If ACL logging was stopped previously because the configured threshold is exceeded, it is re-enabled for this new interval.
The default frequency at which ACL logs are generated is five minutes. By default, flow-based monitoring is not enabled. Command Modes Command History Usage Information ACCESS-LIST Version Description 9.8(0.0) Added the no-drop parameter. 9.7(0.0) Introduced on the S6000–ON. 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms.
8 Access Control List (ACL) VLAN Groups and Content Addressable Memory (CAM) This chapter describes the access control list (ACL) virtual local area network (VLAN) group and content addressable memory (CAM) enhancements. member vlan Add VLAN members to an ACL VLAN group. Syntax member vlan {VLAN-range} Parameters VLAN-range Enter the member VLANs using comma-separated VLAN IDs, a range of VLAN IDs, a single VLAN ID, or a combination.
Parameters group-name Enter the name of the ACL VLAN group where you want the egress IP ACLs applied, up to 140 characters. out Enter the keyword out to apply the ACL to outgoing traffic. implicit-permit Enter the keyword implicit-permit to change the default action of the ACL from implicit-deny to implicit-permit (that is, if the traffic does not match the filters in the ACL, the traffic is permitted instead of dropped).
Vlan Members Test 1-100 - test - The following sample output is displayed when using the show acl-vlan-group group-name option. NOTE: The access list name is truncated. Dell#show acl-vlan-group TestGroupSeventeenTwenty Group Name Egress IP Acl Ingress IP Acl Acl Vlan Members Test test 1-100 Ingress IPV6 The following sample output shows the line-by-line style display when using the show acl-vlan-group detail option.
Example Field Description VlanOpenFlow Number of FP blocks for VLAN open flow operations. VlanIscsi Number of FP blocks for VLAN internet small computer system interface (iSCSI) counters. VlanHp Number of FP blocks for VLAN high performance processes. VlanFcoe Number of FP blocks for VLAN Fiber Channel over Ethernet (FCoE) operations. VlanAclOpt Number of FP blocks for ACL VLAN optimzation feature.
feature is enhanced. A total of four VACP groups are present, of which two are for fixed groups and the other two are for dynamic groups. Out of the total of two dynamic groups, you can allocate zero, one, or two flow processor (FP) blocks to iSCSI Counters, OpenFlow and ACL Optimization. You can configure only two of these features at a point in time. show cam-usage View the amount of CAM space available, used, and remaining in each partition (including IPv4Flow and Layer 2 ACL sub-partitions).
Example 1: Output of Dell#show cam-usage | Total CAM | Used CAM |Available the show cam-usage Linecard|Portpipe| CAM Partition CAM Command ========|========|=================|=============|=============| ============== 1 | 0 | IN-L2 ACL | 1008 | 320 | 688 | | IN-L2 FIB | 32768 | 1132 | 31636 | | IN-L3 ACL | 12288 | 2 | 12286 | | IN-L3 FIB | 262141 | 14 | 262127 | | IN-L3-SysFlow | 2878 | 45 | 2833 | | IN-L3-TrcList | 1024 | 0 | 1024 | | IN-L3-McastFib | 9215 | 0 | 9215 | | IN-L3-Qos | 8192 | 0 | 8192 | | IN
16384 11 8189 196606 2878 1024 9215 8192 1024 Example 4: Output of the show camusage switch Command | 1 | IN-L3 ACL | 8192 | 3 | | | IN-L3 FIB | 196607 | 1 | | | IN-L3-SysFlow | 2878 | 0 | | | IN-L3-TrcList | 1024 | 0 | | | IN-L3-McastFib | 9215 | 0 | | | IN-L3-Qos | 8192 | 0 | | | IN-L3-PBR | 1024 | 0 | | | OUT-L3 ACL | 16384 | 0 | 16384 Dell#show cam-usage switch Linecard|Portpipe| CAM Partition | Total CAM | Used CAM |Available CAM ========|====
Examples The following sample output shows the line-by-line style display when using the show running-config acl-vlan-group option. Note that no group or access list names are truncated Dell#show running-config acl-vlan-group ! acl-vlan-group Test member vlan 1-100 ip access-group test in Dell#show running-config acl-vlan-group ! acl-vlan-group Test member vlan 1-100 ip access-group test in Test acl-vlan-group Create an ACL VLAN group.
show acl-vlan-group detail Display all the ACL VLAN Groups or display a specific ACL VLAN Group by name. To display the names in their entirety, the output displays in a line-by-line format. Syntax show acl-vlan-group detail Parameters detail Display information in a line-by-line format to display the names in their entirety. Without the detail option, the output is displayed in a table style and information may be truncated.
Usage Information Enter a description for each ACL VLAN group that you create for effective and streamlined administrative and logging purposes.
9 Bidirectional Forwarding Detection (BFD) Bidirectional forwarding detection (BFD) is a detection protocol that provides fast forwarding path failure detection.
ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.2.(0.0) Introduced BFD for VRRP and OSPFv3 on Z9000, S4810, and S4820T. 9.0.0.0 Introduced BFD for BGP on the Z9000. 8.3.19.
Re-enable BFD using the no bfd disable command. Defaults BFD is disabled by default. Command Modes VRRP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.2(0.2) Introduced on S4810. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.2.1.
bfd enable (Interface) Enable BFD on an interface. S4810 Syntax bfd enable Defaults BFD is enabled on all interfaces when you enable BFD from CONFIGURATION mode. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.0.0.0 Introduced on the Z9000. 8.3.19.
• Passive — The passive system does not initiate a session. It only responds to a request for session initialization from the active system. The default is Active. Defaults Refer to Parameters. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.
Related Commands Version Description 8.2.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the C-Series. 7.5.1.0 Added support for VLAN and port-channel interfaces on the E-Series. show bfd neighbors — displays the BFD neighbor information on all interfaces or a specified interface. bfd protocol-liveness Enable the BFD protocol liveness feature. S4810 Syntax bfd protocol-liveness Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific.
To disable BFD for all neighbors configured through static routes, use the no ip route bfd [interval interval min_rx min_rx multiplier value role {active | passive}] command. Parameters interval milliseconds (OPTIONAL) Enter the keywords interval to specify non-default BFD session parameters beginning with the transmission interval. The range is from 50 to 1000. The default is 100.
Parameters disable (OPTIONAL) Enter the keyword disable to disable BFD on this interface. interval milliseconds (OPTIONAL) Enter the keyword interval to specify non-default BFD session parameters beginning with the transmission interval. The range is from 50 to 1000. The default is 100. min_rx milliseconds Enter the keywords min_rx to specify the minimum rate at which the local system receives control packets from the remote system. The range is from 50 to 100. The default is 100.
To remove all BFD sessions with IS-IS neighbors discovered on this interface, use the no isis bfd allneighbors [disable | [interval interval min_rx min_rx multiplier value role {active | passive}]] command. Parameters disable (OPTIONAL) Enter the keyword disable to disable BFD on this interface. interval milliseconds (OPTIONAL) Enter the keywords interval to specify non-default BFD session parameters beginning with the transmission interval. The range is from 50 to 1000. The default is 100.
neighbor bfd Explicitly enable a BFD session with a BGP neighbor or a BGP peer group. S4810 Syntax Parameters neighbor {ip-address | peer-group-name} bfd ip-address Enter the IP address of the BGP neighbor that you want to explicitly enable for BFD sessions in dotted decimal format (A.B.C.D). peer-group-name Enter the name of the peer group that you want to explicitly enable for BFD sessions. Defaults none Command Modes ROUTER BGP Command History This guide is platform-specific.
neighbor bfd disable Explicitly disable a BFD session with a BGP neighbor or a BGP peer group. S4810 Syntax neighbor {ip-address | peer-group-name} bfd disable Parameters ip-address Enter the IP address of the BGP neighbor that you want to explicitly disable for BFD sessions in dotted decimal format (A.B.C.D). peer-group-name Enter the name of the peer group that you want to explicitly disable for BFD sessions.
show bfd neighbors Display BFD neighbor information on all interfaces or a specified interface. S4810 Syntax Parameters show bfd neighbors interface [detail] interface detail Defaults Command Modes Command History Enter one of the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
LocalAddr * 10.1.3.2 Example (Detail) RemoteAddr 10.1.3.1 Interface State Rx-int Tx-int Mult Clients Te 1/3 Up 300 250 3 C Dell#show bfd neighbors detail Session Discriminator: 1 Neighbor Discriminator: 1 Local Addr: 10.1.3.2 Local MAC Addr: 00:01:e8:02:15:0e Remote Addr: 10.1.3.
Related Commands Version Description 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.10.0 Introduced on the S4810. 8.2.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the C-Series. 7.5.1.0 Added support for VLAN and port-channel interfaces on the E-Series. 7.4.1.0 Introduced on the E-Series. show bfd neighbors — displays the BFD neighbor information on all interfaces or a specified interface.
10 Border Gateway Protocol BGP is an external gateway protocol that transmits interdomain routing information within and between autonomous systems (AS). BGP version 4 (BGPv4) supports classless inter-domain routing (CIDR) and the aggregation of routes and AS paths. Basically, two routers (called neighbors or peers) exchange information including full routing tables and periodically sent messages to update those routing tables. BGP is supported in Dell Networking OS version 8.3.7.
NOTE: Use this attribute to start a BGP instance corresponding to either a specific address family in a default VRF or an IPv4 address family in a nondefault VRF. ipv6 unicast Enter the keyword ipv6 followed by the keyword unicast to enable BGPv6 mode. vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to install the IPv6 route in that VRF. NOTE: It will not be possible to enable VRF mode for IPv6 unicast without configuring the corresponding IPv4 unicast mode for the same VRF.
AS_SET includes AS_PATH and community information from the routes included in the aggregated route. Defaults attribute-map mapname (OPTIONAL) Enter the keywords attribute-map then the name of a configured route map to modify attributes of the aggregate, excluding AS_PATH and NEXT_HOP attributes. summary-only (OPTIONAL) Enter the keyword summary-only to advertise only the aggregate address. Specific routes are not advertised.
When an aggregate address is denied using a peer's outbound route-map, individual routes suppressed by the aggregate address are advertised to that peer. The attribute-map corresponding to an aggregate address is applied during the outbound update creation time; hence the value set in that attribute-map will not be shown in the output of the show ip bgp aggregate route command.
To disable comparison of MED, enter no bgp always-compare-med. Defaults Disabled (that is, the software only compares MEDs from neighbors within the same AS). Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
Usage Information Version Description 8.3.1.0 Introduced the dynamic application of AS notation changes. 8.2.1.0 Introduced. Before enabling this feature, enable the enable bgp four-octet-as-supportcommand. If you disable the four-octect-support command after using dot or dot+ format, the AS numbers revert to asplain text. When you apply an asnotation, it is reflected in the running-configuration. If you change the notation type, the running-config updates dynamically and the new notation shows.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. If you enable this command, use the clear ip bgp * command to recompute the best path. bgp bestpath as-path multipath-relax Include prefixes received from different AS paths during multipath calculation.
To disable MED comparison on BGP confederation paths, enter the no bgp bestpath med confed command. Defaults Disabled Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.
Usage Information Version Description 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 6.3.1.0 Introduced The MED is a 4-byte unsigned integer value and the default behavior is to assume a missing MED as 4294967295. This command causes a missing MED to be treated as 0. During path selection, paths with a lower MED are preferred over paths with a higher MED. bgp bestpath router-id ignore Do not compare router-id information for external paths during best path selection.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.
Usage Information Version Description 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. When a BGP cluster contains only one route reflector, the cluster ID is the route reflector’s router ID. For redundancy, a BGP cluster may contain two or more route reflectors. Assign a cluster ID with the bgp cluster-id command. Without a cluster ID, the route reflector cannot recognize route updates from the other route reflectors within the cluster.
Usage Information Version Description 7.7.1.0 Introduced on the C-Series. Added support for the 4-byte format To accept 4-byte formats before entering a 4-byte AS number, configure your system. All the routers in the Confederation must be 4 byte or 2 byte identified routers. You cannot mix them. The autonomous systems configured in this command are visible to the EBGP neighbors. Each autonomous system is fully meshed and contains a few connections to other autonomous systems.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Added support for the 4-byte format. All the routers in the Confederation must be 4 byte or 2 byte identified routers. You cannot mix them. The autonomous systems configured in this command are visible to the EBGP neighbors.
bgp dampening Enable BGP route dampening and configure the dampening parameters. S4810 Syntax bgp dampening [half-life reuse suppress max-suppress-time] [route-map mapname] To disable route dampening, use the no bgp dampening [half-life reuse suppress maxsuppress-time] [route-map map-name] command. Parameters half-life (OPTIONAL) Enter the number of minutes after which the Penalty is decreased.
Usage Information Version Description 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. If you enter the bgp dampening command, the default values for half-life, reuse, suppress, and max-suppress-time are applied. The parameters are position-dependent; therefore, if you configure one parameter, configure the parameters in the order they appear in the CLI. Route refresh is sent when you enable BGP dampening. Related Commands show ip bgp dampened-paths — views the BGP paths.
bgp dmzlink-bw Enables BGP Link Bandwidth. S4810 Syntax bgp dmzlink-bw To disable BGP Link Bandwidth, enter the no bgp dmzlink-bw command. Parameters dmzlink-bw Defaults N/A Command Modes ROUTER BGP Command History Usage Information Enter the keyword dmzlink-bw to enable BGP Link Bandwidth in BGP multipath. Version Description 9.7(0.0) Introduced on the S-Series.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 7.4.1.0 Introduced. This command is enabled by default, that is for all updates received from EBGP peers, BGP ensures that the first AS of the first AS segment is always the AS of the peer.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. The bgp fast-external-fallover command appears in the show config command output. The fast external fallover configuration is applied only after you manually reset all the existing BGP sessions. As a result, after you execute this command, you must also manually execute the clear ip bgp command in order for the configuration to take effect.
This command automatically restarts the BGP instance for the configuration to take effect. bgp graceful-restart To support graceful restart as a receiver only, enable graceful restart on a BGP neighbor, a BGP node, or designate a local router. S4810 Syntax bgp graceful-restart [restart-time seconds] [stale-path-time seconds] [role receiver-only] To return to the default, use the no bgp graceful-restart command.
bgp non-deterministic-med Compare MEDs of paths from different autonomous systems. Syntax bgp non-deterministic-med To return to the default, use the no bgp non-deterministic-med command. Defaults Disabled (that is, paths/routes for the same destination but from different ASs do not have their MEDs compared). Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 7.2.1.0 Introduced. This command is a knob to disable BGP next-hop resolution using BGP learned routes.
Usage Information Version Description 7.6.1.0 Introduced BGP uses regular expressions (regex) to filter route information. In particular, the use of regular expressions to filter routes based on AS-PATHs and communities is common. In a large-scale configuration, filtering millions of routes based on regular expressions can be quite CPU intensive, as a regular expression evaluation involves generation and evaluation of complex finite state machines.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Peering sessions are reset when you change the router ID of a BGP router. This command automatically restarts the BGP instance for the configuration to take effect. clear ip bgp Reset BGP sessions.
dampening Enter the keyword dampening to clear the flap dampening information. flap-statistics Enter the keywords flap-statistics to clear the flap statistics information. ipv4 Enter the ipv4 address family to clear. ipv6 Enter the ipv6 address family to clear. peer-group Enter the peer-group to clear all members of the peer-group. Command Modes EXEC Privilege Command History This guide is platform-specific.
ipv6 unicast (OPTIONAL) Enter the keyword ipv6 followed by the keyword unicast to clear the ipv6 unicast routes. ipv4-address mask (OPTIONAL) Enter an IPv4 address in dotted decimal format and the prefix mask in slash format (/x) to clear dampening information only that BGP neighbor. ipv6–address mask (OPTIONAL) Enter the IPv6 address and the network mask to clear information on IPv6 route dampening. Command Modes EXEC Privilege Command History This guide is platform-specific.
ipv4 unicast (OPTIONAL) Enter the keyword ipv4 followed by the keyword unicast to clear information related only to ipv4 unicast routes. ipv6 unicast (OPTIONAL) Enter the keyword ipv6 followed by the keyword unicast to clear information related only to ipv6 unicast routes. ipv4-address mask (OPTIONAL) Enter an IPv4 address in dotted decimal format and the prefix mask in slash format (/x) to reset only that prefix.
Related Commands show debugging — views the enabled debugging operations. show ip bgp flap-statistics — views the BGP flap statistics. undebug all — disables all debugging operations. clear ip bgp peer-group Reset a peer-group’s BGP sessions. S4810 Syntax clear ip bgp [vrf vrf-name] peer-group peer-group-name [ipv4 [multicast | unicast] | ipv6 unicast] [soft {in | out}] Parameters vrf vrf-name Enter the keyword vrf and then the name of the VRF to reset the peer group corresponding to that VRF.
Version Description 7.7.1.0 Introduced on the C-Series. deny bandwidth Enables you to specify link band width extended-community attribute as the matching criteria to deny incoming or outgoing traffic. Syntax deny bandwidth To disable this setting, enter the no deny bandwidth command. Parameters bandwidth Enter the keyword bandwidth to specify extended-community attribute as the matching criteria for denying traffic. The range is from 0 to 102400.
X:X:X:X::X Enter the IPv6 IP address of peer in the X:X:X:X::X format. dampening Enter the keyword dampening to view BGP dampening. events Enter the keyword events to view BGP protocol events. ipv4 Enter the ipv4 IP address to view the IPV4 route information. ipv6 Enter the ipv6 IP address to view the IPV6 route information. keepalives Enter the keyword keepalives to view BGP keepalives. notifications Enter the keyword notifications to view BGP notifications.
debug ip bgp dampening View information on routes being dampened. S4810 Syntax debug ip bgp [vrf vrf-name] [ipv4 {unicast | multicast} | ipv6 unicast] dampening To disable debugging, use the no debug ip bgp dampening command. Parameters vrf vrf-name Enter the keyword vrf followed by the name of the VRF to view information on dampened routes corresponding to that VRF.
To disable debugging, use the no debug ip bgp [vrf vrf-name] [A.B.C.D | X:X:X:X::X | peer-group peer-group-name] events [in | out] command. Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to display BGP state changes corresponding to that VRF. A.B.C.D (OPTIONAL) Enter the IPv4 address of the neighbor. X:X:X:X::X (OPTIONAL) Enter an IPv6 address. peer-group peergroup-name (OPTIONAL) Enter the keyword peer-group then the name of the peer group.
A.B.C.D (OPTIONAL) Enter the IPv4 address of the neighbor. X:X:X:X::X (OPTIONAL) Enter an IPv6 address. peer-group peergroup-name (OPTIONAL) Enter the keyword peer-group then the name of the peer group. in (OPTIONAL) Enter the keyword in to view only inbound keepalive messages. out (OPTIONAL) Enter the keyword out to view only outbound keepalive messages. Command Modes EXEC Privilege Command History This guide is platform-specific.
out (OPTIONAL) Enter the keyword out to view BGP notifications sent to neighbors Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added ipv6 support. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T.
Usage Information Version Description 9.7(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 7.2.1.0 Introduced. This command turns on BGP soft-reconfiguration inbound debugging. If no neighbor is specified, debug turns on for all neighbors.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.
Version Description 7.7.1.0 Introduced on the C-Series. Usage Information The default-metric command in BGP sets the value of the BGP MULTI_EXIT_DISC (MED) attribute for redistributed routes only. Related Commands bgp always-compare-med — enables comparison of all BGP MED attributes. redistribute — redistributes routes from other routing protocols into BGP.
maximum-paths Configure the maximum number of parallel routes (multipath support) BGP supports. S4810 Syntax maximum-paths {ebgp | ibgp} number To return to the default values, enter the no maximum-paths command. Parameters ebgp Enter the keyword ebgp to enable multipath support for External BGP routes. ibgp Enter the keyword ibgp to enable multipath support for Internal BGP routes. number Enter a number as the maximum number of parallel paths. The range is from 2 to 64.
peer-group-name (OPTIONAL) Enter the name of the peer group. activate Enter the keyword activate to enable the neighbor/peer group in the new AFI/ SAFI. Defaults Disabled Command Modes CONFIGURATION-ROUTER-BGP-ADDRESS FAMILY Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Introduced on the S4810.
Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. neighbor advertisement-start To send BGP routing updates, set the minimum interval before starting. S4810 Syntax neighbor {ip-address} advertisement-start seconds To return to the default value, use the no neighbor {ip-address} advertisement-start command. Parameters ip-address (OPTIONAL) Enter the IP address of the neighbor in dotted decimal format.
Parameters ip-address (OPTIONAL) Enter the IP address of the neighbor in dotted decimal format. peer-group-name Enter the name of the peer group to set the advertisement interval for all routers in the peer group. number Enter a number of times to allow this neighbor ID to use the AS path. The range is from 1 to 10. Defaults Not configured. Command Modes ROUTER BGP Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series.
text Enter a continuous text string up to 80 characters. Defaults Not configured. Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Usage Information Other BGP filtering commands include: neighbor filter-list, ip as-path access-list, and neighbor route-map.
Usage Information Version Description 7.7.1.0 Introduced on the C-Series. To prevent loops, the neighbor ebgp-multihop command does not install the default routes of the multihop peer. Networks not directly connected are not considered valid for best-path selection. neighbor fall-over Enable or disable fast fall-over for BGP neighbors. S4810 Syntax neighbor {ipv4-address | peer-group-name} fall-over To disable, use the no neighbor {ipv4-address | peer-group-name} fall-over command.
neighbor local-as To accept external routes from neighbors with a local AS number in the AS number path, configure Internal BGP (IBGP) routers. S4810 Syntax neighbor {ip-address | peer-group-name} local-as as-number [no-prepend] To return to the default value, use the no neighbor {ip-address | peer-group-name} local-as command. Parameters ip-address Enter the IP address of the neighbor in dotted decimal format.
neighbor maximum-prefix Control the number of network prefixes received. S4810 Syntax neighbor {ip-address | peer-group-name} maximum-prefix maximum [threshold] [warning-only] To return to the default values, use the no neighbor {ip-address | peer-group-name} maximum-prefix maximum command. Parameters ip-address Enter the IP address of the neighbor in dotted decimal format. peer-group-name Enter the name of the peer group.
neighbor remains down until you enter the clear ip bgp command for the neighbor or the peer group to which the neighbor belongs or you enter the neighbor shutdown and neighbor no shutdown commands. Related Commands show ip bgp summary — displays the current BGP configuration. neighbor password Enable message digest 5 (MD5) authentication on the TCP connection between two neighbors.
Configuring a password for a neighbor causes an existing session to be torn down and a new one established. If you specify a BGP peer group by using the peer-group-name parameter, all the members of the peer group inherit the characteristic configured with this command.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. You can assign up to 256 peers to one peer group. When you add a peer to a peer group, it inherits all the peer group’s configured parameters.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Usage Information When you create a peer group, it is disabled (Shut mode).
Usage Information Version Description 8.3.8.0 Introduced the limit keyword on the S4810. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. After you configure a peer group as passive, assign it a subnet using the neighbor softreconfiguration inbound command. For passive eBGP limits, the Remote AS must be different from the AS for this neighbor.
Usage Information Version Description 7.7.1.0 Introduced on the C-Series. Added 4-byte support. To accept 4-byte formats before entering a 4 byte AS Number, configure your system. If the number parameter is the same as the AS number used in the router bgp command, the remote AS entry in the neighbor is considered an internal BGP peer entry. This command creates a peer and the newly created peer is disabled (Shutdown).
Configure your system to accept 4-byte formats before entering a 4 byte AS Number. If the AS-PATH contains both public and private AS number or contains AS numbers of an EBGP neighbor, the private AS numbers are not removed. If a confederation contains private AS numbers in its AS-PATH, the software removes the private AS numbers only if they follow the confederation numbers in the AS path. Private AS numbers are from 64512 to 65535 (2 byte).
Usage Information Version Description 7.7.1.0 Introduced on the C-Series. When you apply a route map to outbound routes, only routes that match at least one section of the route map are permitted. If you identify a peer group by name, the peers in that peer group inherit the characteristics in the Route map used in this command. If you identify a peer by IP address, the Route map overwrites either the inbound or outbound policies on that peer.
The first time you enter this command, the router configures as a route reflector and the specified BGP neighbors configure as clients in the route-reflector cluster. When you remove all clients of a route reflector using the no neighbor route-reflector-client command, the router no longer functions as a route reflector.
Related Commands bgp client-to-client reflection — enables route reflection between the route reflector and the clients. neighbor send-community Send a COMMUNITY attribute to a BGP neighbor or peer group. A COMMUNITY attribute indicates that all routes with that attribute belong to the same community grouping.
neighbor shutdown Disable a BGP neighbor or peer group. S4810 Syntax neighbor {ip-address | peer-group-name} shutdown To enable a disabled neighbor or peer group, use the neighbor {ip-address | peer-groupname}no shutdown command. Parameters ip-address Enter the IP address of the neighbor in dotted decimal format. peer-group-name Enter the name of the peer group to disable or enable all routers within the peer group. Defaults Enabled (that is, BGP neighbors and peer groups are disabled.
To disable, use the no neighbor {ip-address | peer-group-name} softreconfiguration inbound command. Parameters ip-address Enter the IP address of the neighbor in dotted decimal format. peer-group-name Enter the name of the peer group to disable or enable all routers within the peer group. Defaults Disabled Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Parameters Defaults ip-address Enter the IP address of the peer router in dotted decimal format. peer-group-name Enter the name of the peer group to set the timers for all routers within the peer group. keepalive Enter a number for the time interval, in seconds, between keepalive messages sent to the neighbor routers. The range is from 1 to 65535. The default is 60 seconds. holdtime Enter a number for the time interval, in seconds, between the last keepalive message and declaring the router dead.
To use the closest interface, use the no neighbor {ip-address | peer-group-name} update-source interface command. Parameters ip-address Enter the IP address of the peer router in dotted decimal format. peer-group-name Enter the name of the peer group to disable all routers within the peer group. interface Enter the keyword loopback then a number of the Loopback interface. The range is from 0 to 16383. Defaults Not configured.
Defaults 0 Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
• set community • set local-preference • set metric • set next-hop • set origin • set weight If the route map is not configured, the default is deny (to drop all routes). Defaults Not configured. Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
network backdoor Specify this IGP route as the preferred route. S4810 Syntax network ip-address mask backdoor To remove a network, use the no network ip-address mask backdoor command. Parameters ip-address Enter an IP address in dotted decimal format of the network. mask Enter the mask of the IP address in the slash prefix length format (for example, / 24). The mask appears in command outputs in dotted decimal format (A.B.C.D). Defaults Not configured.
Command Modes Command History Related Commands EXTENDED COMMUNITY LIST Version Description 9.7(0.0) Introduced on the S-Series. deny bandwidth – link band width extended-community attribute as the matching criteria to deny incoming or outgoing traffic.. redistribute Redistribute routes into BGP. S4810 Syntax redistribute {connected | static} [route-map map-name] To disable redistribution, use the no redistribution {connected | static} command.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced the ability to substitute IGP cost for MED when a peer/peer-group outbound route-map is set as internal. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. You can use the redistribute command to advertise the IGP cost as the MED on redistributed routes.
Defaults Not configured. Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. At least one interface must be in Layer 3 mode for the router bgp command to be accepted.
show capture bgp-pdu neighbor Display BGP packet capture information for an IPv4 address on the system. S4810 Syntax show capture bgp-pdu neighbor ipv4-address Parameters ipv4-address Enter the IPv4 address (in dotted decimal format) of the BGP address to display packet information for that address. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
[. . .] Dell# show config View the current ROUTER BGP configuration. S4810 Syntax show config Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Command Modes Command History network-mask (OPTIONAL) Enter the network mask (in slash prefix format) of the BGP network address. longer-prefixes (OPTIONAL) Enter the keywords longer-prefixes to view all routes with a common prefix. • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
BGP local router ID is 192.168.11.5 Status codes: s suppressed, S stale, d dampened, h history, * valid, > best Path source: I - internal, a - aggregate, c - confed-external, r redistributed n - network, D - denied, S - stale Origin codes: i - IGP, e - EGP, ? - incomplete *> *> Network 55.0.0.0/24 66.0.0.0/24 Next Hop 172.16.0.2 172.16.0.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example Version Description 9.7(0.0) Added the ipv4 multicast and ipv6 unicast parameters. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000.
500 600 i *>I 66.0.0.0/24 *>I 77.0.0.0/24 Dell# 172.16.0.2 172.16.0.2 0 0 0 500 i 0 i show ip bgp community View information on all routes with Community attributes or view specific BGP community groups.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added the ipv4 multicast and ipv6 unicast parameters. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
*> 66.0.0.0/24 172.16.0.2 0 200 i Dell#show ip bgp community no-advertise BGP local RIB : Routes to be Added 0, Replaced 0, Withdrawn 0 BGP local router ID is 192.168.11.5 Status codes: s suppressed, S stale, d dampened, h history, * valid, > best Path source: I - internal, a - aggregate, c - confed-external, r redistributed n - network, D - denied, S - stale Origin codes: i - IGP, e - EGP, ? - incomplete *> Network 66.0.0.0/24 Next Hop 172.16.0.
Usage Information Version Description 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. The show ip bgp community-list command without any parameters lists BGP routes matching the Community List and the output is the same as for the show ip bgp command output. The following describes the show ip bgp community-list pass command shown in the following example. Example Field Description Network Displays the destination network prefix of each BGP route.
show ip bgp dampened-paths View BGP routes that are dampened (non-active). S4810 Syntax Parameters Command Modes Command History show ip bgp [vrf vrf-name] [ipv4 {multicast | unicast} | ipv6 unicast] dampened-paths vrf vrf-name (OPTIONAL) Enter the keywords vrf and then the name of the VRF to view routes that are affected by a specific community list corresponding to that VRF.
Example Field Description Network Displays the network ID to which the route is dampened. From Displays the IP address of the neighbor advertising the dampened route. Reuse Displays the hour:minutes:seconds until the dampened route is available. Path Lists all the ASs the dampened route passed through to reach the destination network. Dell#show ip bgp dampened-paths BGP local RIB : Routes to be Added 0, Replaced 0, Withdrawn 0 BGP local router ID is 192.168.11.
Example Dell#show ip bgp detail Detail information for BGP Node bgpNdP 0x41a17000 : NdTmrP 0x41a17000 : NdKATmrP 0x41a17014 : NdTics 74857 : NhLocAS 1 : NdState 2 : NdRPMPrim 1 : NdListSoc 13 NdAuto 1 : NdEqCost 1 : NdSync 0 : NdDefOrg 0 NdV6ListSoc 14 NdDefDid 0 : NdConfedId 0 : NdMedConfed 0 : NdMedMissVal -1 : NdIgnrIllId 0 : NdRRC2C 1 : NdClstId 33686273 : NdPaTblP 0x41a19088 NdASPTblP 0x41a19090 : NdCommTblP 0x41a19098 : NhOptTransTblP 0x41a190a0 : NdRRClsTblP 0x41a190a8 NdPktPA 0 : NdLocCBP 0x41a6f00
AfActPeerHd 0x41a1a3a4 : AfExtDist 1101112312 : AfIntDist 200 : AfLocDist 200 AfNumRRc 0 : AfRR 0 : AfNetRttP 0x41a0d300 : AfNetCtxAddr 1101112392 : AfNetCtxAddrlen 255 AfNwCtxAddr 1101112443 : AfNwCtxAddrlen 255 : AfNetBKDrRttP 0x41a0d500 : AfNetBKDRCnt 0 : AfDampHLife 0 AfDampReuse 0 : AfDampSupp 0 : AfDampMaxHld 0 : AfDampCeiling 0 : AfDampRmapP show ip bgp extcommunity-list View information on all routes with Extended Community attributes.
Usage Information To view the total number of COMMUNITY attributes found, use the show ip bgp summary command. The text line above the route table states the number of COMMUNITY attributes found. The show ip bgp community command without any parameters lists BGP routes with at least one BGP community attribute and the output is the same as for the show ip bgp command output.
Usage Information Example Version Description 9.7(0.0) Added the ipv4 multicast and ipv6 unicast parameters. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. The following describes the show ip bgp filter-list hello command shown in the following example.
show ip bgp flap-statistics View flap statistics on BGP routes. S4810 Syntax Parameters show ip bgp [vrf vrf-name] [ipv4 {multicast | unicast} | ipv6 unicast] flap-statistics [ip-address [mask]] [filter-list as-path-name] [regexp regular-expression] vrf vrf-name (OPTIONAL) Enter the keywords vrf and then the name of the VRF to view flap statistics on BGP routes corresponding to that VRF.
The following is a list of the Dell Networking OS version history for this command. Usage Information Example Version Description 9.7(0.0) Added the ipv4 multicast and ipv6 unicast parameters. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series.
Parameters Command Modes Command History vrf vrf-name (OPTIONAL) Enter the keyword vrf and then the name of the VRF to view routes corresponding to the VRF that contain inconsistent originating AS numbers. ipv4 unicast (OPTIONAL) Enter the keywords ipv4 unicast to view information only related to ipv4 unicast routes. • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
*> 3.18.135.0/24 * * * *> 4.0.0.0/8 * * * * 6.0.0.0/20 * *> * * 9.2.0.0/16 * --More-- 63.114.8.60 63.114.8.34 63.114.8.33 63.114.8.33 63.114.8.60 63.114.8.34 63.114.8.33 63.114.8.33 63.114.8.60 63.114.8.34 63.114.8.33 63.114.8.33 63.114.8.60 63.114.8.
ipv6 unicast (OPTIONAL) Enter the keyword ipv6 followed by the keyword unicast to view information related only to ipv6 unicast routes. ip-address (OPTIONAL) Enter the IP address of the neighbor to view only BGP information exchanged with that neighbor. advertised-routes (OPTIONAL) Enter the keywords advertised-routes to view only the routes the neighbor sent. dampened-routes (OPTIONAL) Enter the keywords dampened-routes to view information on dampened routes from the BGP neighbor.
Usage Information Version Description 7.2.1.0 Added the received and denied route options. 6.3.10 The output is changed to display the total number of advertised prefixes. After a peer reset, the contents of the notification log messages is displayed in hex values for debugging. The neighbor information that this command displays does not include counts corresponding to ignored prefixes and updates.
Example The Lines Beginning with: Description accepted prefixes Displays the number of network prefixes the router accepts and the amount of memory used to process those prefixes. Prefix advertised Displays the number of network prefixes advertised, the number rejected, and the number withdrawn from the BGP routing table. Connections established Displays the number of TCP connections established and dropped between the two peers to exchange BGP information.
Dell# Related Commands show ip bgp — views the current BGP routing table. show ip bgp next-hop View all next hops (using learned routes only) with current reachability and flap status. This command only displays one path, even if the next hop is reachable by multiple paths.
Example Dell# show ip bgp next-hop Next-hop Resolved 172.16.0.2 YES Dell# show ip bgp paths View all the BGP path attributes in the BGP database. Syntax Parameters show ip bgp[vrf vrf-name] paths [regexp regular-expression] vrf vrf-name (OPTIONAL) Enter the keyword vrf to view all path attributes in the BGP database corresponding to that VRF.
Usage Information Example Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. The following describes the show ip bgp path command shown in the following example. Field Description Total Displays the total number of BGP path attributes. Address Displays the internal address where the path attribute is stored. Hash Displays the hash bucket where the path attribute is stored.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Command Modes Command History ipv4 unicast (OPTIONAL) Enter the keyword ipv4 followed by the keyword unicast to view information related only to ipv4 unicast routes. ipv6 unicast (OPTIONAL) Enter the keyword ipv6 followed by the keyword unicast to view information related only to ipv6 unicast routes. peer-group-name (OPTIONAL) Enter the name of a peer group to view information about that peer group only.
Example Line beginning with: Description Number of peers Displays the number of peers currently configured for this peer group. Peer-group members: Lists the IP addresses of the peers in the peer group. If the address is outbound optimized, an * is displayed next to the IP address.
Command Modes Command History • EXEC • EXEC Privilege • ^ = (caret) the beginning of the input string. If you use the caret at the beginning of a sequence or range, it matches on everything BUT the characters specified. • $ = (dollar sign) the end of the output string. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
show ip bgp summary Allows you to view the status of all BGP connections. S4810 Syntax Parameters Command Modes Command History show ip bgp [vrf vrf-name] [ipv4 {multicast | unicast} | ipv6 unicast] summary vrf vrf-name (OPTIONAL) Enter the keyword vrf and then the name of the VRF to view the status of all BGP connections corresponding to that VRF. ipv4 multicast (OPTIONAL) Enter the keyword ipv4 followed by the keyword multicast to view information related only to ipv4 multicast routes.
If two peers send the same route that contains similar path attributes, then two entries are maintained in the back-end, as both these entries have different next-hops. If this same route is sent to a different peer, an entry for each peer is created, as the next-hop is different. As a result, the BGP attributes count in the summary output will differ accordingly. The following describes the show ip bgp summary command shown in the following example.
Field Description State/Pfxrcd If the neighbor is in Established stage, the number of network prefixes received. If a maximum limit was configured with the neighbor maximum-prefix command, (prfxd) appears in this column. If the neighbor is not in Established stage, the current stage is displayed (Idle, Connect, Active, OpenSent, OpenConfirm). When the peer is transitioning between states and clearing the routes received, the phrase (Purging) may appear in this column.
Example Version Description 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 7.6.1.0 Introduced on the E-Series. Dell#show running-config bgp ! router bgp 100 network 1.1.11.1/32 network 1.1.12.1/32 network 1.1.13.1/32 neighbor 10.1.1.2 remote-as 200 neighbor 10.1.1.2 no shutdown Dell# timers bgp Adjust the BGP Keep Alive and Hold Time timers. S4810 Syntax timers bgp keepalive holdtime To return to the default, use the no timers bgp command.
MBGP Commands Multiprotocol BGP (MBGP) is an enhanced BGP that enables multicast routing policy throughout the internet and connecting multicast topologies between BGP and autonomous systems (ASs). Dell Networking OS MBGP is implemented as per IETF RFC 1858. BGPv4 is supported in the following: Dell Networking OS Version Platform Support 7.8.1.0, MBGP for IPv4 Multicast Only S-Series debug ip bgp dampening View information on routes being dampened.
Version Description 7.6.1.0 Introduced IPv6 MGBP support for the E-Series. distance bgp Configure three administrative distances for routes. S4810 Syntax distance bgp external-distance internal-distance local-distance To return to default values, use the no distance bgp command. Parameters Defaults external-distance Enter a number to assign to routes learned from a neighbor external to the AS. The range is from 1 to 255. The default is 20.
show ip bgp dampened-paths View BGP routes that are dampened (non-active). S4810 Syntax Parameters Command Modes Command History show ip bgp [vrf vrf-name] [ipv4 {multicast | unicast} | ipv6 unicast] dampened-paths vrf vrf-name (OPTIONAL) Enter the keywords vrf and then the name of the VRF to view routes that are affected by a specific community list corresponding to that VRF.
Example Field Description Network Displays the network ID to which the route is dampened. From Displays the IP address of the neighbor advertising the dampened route. Reuse Displays the hour:minutes:seconds until the dampened route is available. Path Lists all the ASs the dampened route passed through to reach the destination network. Dell#show ip bgp dampened-paths BGP local RIB : Routes to be Added 0, Replaced 0, Withdrawn 0 BGP local router ID is 192.168.11.
non-trans (OPTIONAL) Enter the keywords non-trans to indicate a non-transitive BGP extended community. Defaults none Command Modes ROUTE MAP (config-route-map) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Related Commands Version 8.3.19.0 Introduced on the S4820T Version 8.3.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Related Commands Version 8.3.19.0 Introduced on the S4820T. Version 8.3.11.1 Introduced on the Z9000. Version 8.3.7.0 Introduced on the S4810. Version 7.8.1.0 Introduced on the S-Series. Version 7.7.1.0 Introduced on the C-Series.
Example Field Description Address Displays the internal address where the path attribute is stored. Hash Displays the hash bucket where the path attribute is stored. Refcount Displays the number of BGP routes using these extended communities. Community Displays the extended community attributes in this BGP path. Dell#show ip bgp paths extcommunity Total 1 Extended Communities Address 0x41d57024 Hash Refcount Extended Community 12272 1 RT:7:200 SoO:5:300 SoO:0.0.0.
IPv6 BGP Commands IPv6 border gateway protocol (IPv6 BGP) is supported on the S4810 platform. BGP is an external gateway protocol that transmits interdomain routing information within and between Autonomous Systems (AS). Basically, two routers (called neighbors or peers) exchange information including full routing tables and periodically send messages to update those routing tables.
debug ip bgp ipv6 unicast soft-reconfiguration Enable soft-reconfiguration debugging for IPv6 unicast routes. S4810 Syntax debug ip bgp [ipv4-address | ipv6-address | peer-group-name] ipv6 unicast soft-reconfiguration To disable debugging, use the no debug ip bgp [ipv4-address | ipv6-address | peergroup-name] ipv6 unicast soft-reconfiguration command. Parameters ipv4-address | ipv6address Enter the IP address of the neighbor on which you want to enable softreconfiguration debugging.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant FTOS Command Line Reference Guide. The following is a list of the FTOS version history for this command. Version Description 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.10.0 Introduced on the S4810.
show ipv6 prefix-list Displays the specified IPv6 prefix list. S4810 Syntax Parameters show ipv6 prefix-list detail {prefix-list name} | summary detail Display a detailed description of the selected IPv6 prefix list. prefix-list name Enter the name of the prefix list. NOTE: There is a 140-character limit for prefix list names. summary Display a summary of RPF routes. Command Modes EXEC Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant FTOS Command Line Reference Guide. The following is a list of the FTOS version history for this command. 448 Version Description 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.10.0 Introduced on the S4810.
11 Content Addressable Memory (CAM) Content addressable memory (CAM) commands are supported on the Dell Networking S4810 platform. NOTE: Not all CAM commands are supported on all platforms. Be sure to note the platform when looking for a command. WARNING: If you are using these features for the first time, contact Dell Networking Technical Assistance Center (TAC) for guidance. CAM Profile Commands The CAM profiling feature allows you to partition the CAM to best suit your application.
number] ecfmacl number [nlbclusteracl number] ipv4pbr number }openflow number | fcoe number} [iscsioptacl number] [vrfv4acl number] Parameters 450 default Use the default CAM profile settings and set the CAM as follows: • L2Acl : 6 • IPV4Acl : 4 • IPV6Acl : 0 • IPV4Qos : 2 • L2Qos : 1 • L2PT : 0 • IpMacAcl : 0 • VmanQos : 0 • VmanDualQos : 0 • EcfmAcl : 0 • nlbclusteracl: 0 • FcoeAcl : 0 • iscsiOptAcl : 0 • ipv4pbr : 0 • vrfv4Acl :0 • Openflow : 0 • fedgovacl : 0 l2acl n
NOTE: When you reconfigure CAM allocation, use the nlbclusteracl number command to change the number of NLB ARP entries. The range is from 0 to 2. The default value is 0. At the default value of 0, eight NLB ARP entries are available for use. This platform supports up to 512 CAM entries. Select 1 to configure 256 entries. Select 2 to configure 512 entries.
Usage Information Version Description 9.4.(0.0) Added support for PBR and VRF. 9.2(0.2) Added support for fcoe. 9.1.(0.0) Added support for OpenFlow. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.10.2 Clarified block information for the S4810. 8.3.10.0 Introduced on the S4810. 8.3.1.0 Added the keywords ecfmacl, vman-qos, and vman-dual-qos. 8.2.1.0 Introduced on the S-Series. 7.8.1.0 Introduced on the C-Series.
Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. cam-optimization Optimize CAM utilization for QoS Entries by minimizing require policy-map CAM space. S4810 Syntax Parameters cam-optimization [qos] qos Optimize CAM usage for QoS. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific.
show cam-acl Display the details of the CAM profiles on the chassis and all stack units. S4810 Syntax show cam-acl Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000.
VmanQos : VmanDualQos : EcfmAcl : FcoeAcl : iscsiOptAcl : ipv4pbr : vrfv4Acl : Openflow : fedgovacl : nlbclusteracl: 0 0 0 0 0 0 0 0 0 0 -- stack-unit 1 -Current Settings(in block sizes) 1 block = 128 entries L2Acl : 6 Ipv4Acl : 4 Ipv6Acl : 0 Ipv4Qos : 2 L2Qos : 1 L2PT : 0 IpMacAcl : 0 VmanQos : 0 VmanDualQos : 0 EcfmAcl : 0 FcoeAcl : 0 iscsiOptAcl : 0 ipv4pbr : 0 vrfv4Acl : 0 Openflow : 0 fedgovacl : 0 nlbclusteracl: 0 test cam-usage Verify that enough CAM space is available for the IPv6 ACLs you have c
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced. This command applies to both IPv4 and IPv6 CAM Profiles, but is best used when verifying QoS optimization for IPv6 AC QoS Optimization for IPv6 ACLs does not impact the CAM usage for applying a policy on a single (or the first of several) interfaces. It is most useful when a policy is applied across multiple interfaces; it can reduce the impact to CAM usage acr subsequent interfaces.
Example (S-Series) Dell#test cam-usage service-policy input LauraIn stack-unit all Stack-Unit|Portpipe|CAM Partition|AvailableCAM|EstimatedCAM per Port|Status -----------------------------------------------------------------------0| 0| IPv4Flow| 102| 0|Allowed 0| 0| IPv4Flow| 102| 0|Allowed Dell# ! Dell#test cam-usage service-policy input LauraIn stack-unit 0 port-set 1 Stack-Unit|Portpipe|CAM Partition|Available CAM|EstimatedCAM per Port|Status -------------------------------------------------------------
12 Control Plane Policing (CoPP) The CoPP commands are supported on the Dell Networking S4810 platform. control-plane-cpuqos To manage control-plane traffic, enter control-plane mode and configure the switch. S4810 Syntax control-plane-cpuqos Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Introduced on the S4810.
Usage Information Version Description 8.3.8.0 Introduced on the S4810. This command applies the service-policy based on the type of protocol defined in the ACL rules. Create ACL and QoS policies prior to enabling this command. For CoPP, use the keyword cpu-qos when creating qos-policy-input. Related Commands ip access-list extended — creates an extended IP ACL. mac access-list extended — creates an extended MAC ACL. qos-policy-input — creates a QoS input policy map.
ipv6 unknown-unicast Disable soft forwarding of unknown IPv6 destination packets. S4810 Syntax [no] ipv6 unknown-unicast Defaults Soft forwarding is enabled. Command Modes CONFIGURATION Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000.
Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8 Q9 Q10 Q11 300 300 400 2000 300 400 400 400 600 300 300 50 50 50 50 50 50 50 50 50 50 50 show ip protocol-queue-mapping Display the queue mapping for each configured protocol. S4810 Syntax show ip protocol-queue-mapping Defaults Not configured. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Dell# Dell# show ipv6 protocol-queue-mapping Display the queue mapping for each configured IPv6 protocol. S4810 Syntax show ipv6 protocol-queue-mapping Defaults Not configured. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.
Defaults Not configured. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.
13 Data Center Bridging (DCB) Data center bridging (DCB) refers to a set of IEEE Ethernet enhancements that provide data centers with a single, robust, converged network to support multiple traffic types, including local area network (LAN), server, and storage traffic. The Dell Networking operating software commands for data center bridging features include 802.1Qbb priority-based flow control (PFC), 802.1Qaz enhanced transmission selection (ETS), and the data center bridging exchange (DCBX) protocol.
Usage Information Version Description 8.3.12.0 Introduced on the S4810. 8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module. By default, iSCSI is enabled on the unit and the flow control is enabled on all of the interfaces. It is also acts as defaults when the link-level flow control is enabled on one or more interfaces. Enables priority flow control or enhance transmission selection on interface.
description Enter a text description of the DCB policy (PFC input or ETS output). Syntax description text To remove the text description, use the no description command. Parameters Defaults Command Modes Command History text Enter the description of the output policy. The maximum is 32 characters. none • DCB INPUT POLICY • DCB OUTPUT POLICY This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Usage Information NOTE: Please note that Dell Networking does not recommended to use this command as it has been deprecated in the current 9.4.(0.0) release. A warning message appears when you try to run this command indicating that you have to use the dcb-map commands in the future. By applying a DCB input policy with PFC enabled, you enable PFC operation on ingress port traffic.
dot1p Value in the Incoming Frame Description heading 0 0 1 0 2 0 3 1 4 2 5 3 6 3 7 3 show dcb Displays the data center bridging status, the number of PFC-enabled ports, and the number of PFC-enabled queues. Syntax Parameters show dcb [stack-unit unit-number] [port-set port-set-number] unit-number Enter the DCB unit number. port-set-number Enter the port-set number. Command Modes EXEC Privilege Command History This guide is platform-specific.
Parameters port-type slot/ port[] pfc Enter the port-type slot and port PFC information. {summary | detail} Enter the keyword summary for a summary list of results or enter the keyword detail for a full list of results. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Field Description TLV Tx Status Status of the PFC TLV advertisements: enabled or disabled. PFC Link Delay Link delay (in quanta) used to pause specified priority traffic. Application Priority TLV: FCOE TLV Tx Status Status of FCoE advertisements in application priority TLVs from the local DCBX port: enabled or disabled. Application Priority TLV: SCSI TLV Tx Status Status of ISCSI advertisements in application priority TLVs from the local DCBX port: enabled or disabled.
Remote ISCSI PriorityMap is 0x8 Dell# show interfaces tengigabitethernet 1/4 pfc detail Interface TenGigabitEthernet 1/4 Admin mode is on Admin is enabled Remote is enabled Remote Willing Status is enabled Local is enabled Oper status is recommended PFC DCBX Oper status is Up State Machine Type is Feature TLV Tx Status is enabled PFC Link Delay 45556 pause quanta Application Priority TLV Parameters : -------------------------------------FCOE TLV Tx Status is disabled ISCSI TLV Tx Status is disabled Local FC
4 5 6 0 7 0 0 0 0 0 0 0 0 show stack-unit stack-ports pfc details Displays the PFC configuration applied to ingress traffic on stacked ports, including PFC Operational mode on each unit with the configured priorities, link delay, and number of pause packets sent and received. Syntax Parameters show stack-unit {all | stack-unit} stack-ports {all | port-number} pfc details stack-unit Enter the stack unit. port-number Enter the port number.
bandwidth-percentage Configure the bandwidth percentage allocated to priority traffic in port queues. Syntax bandwidth-percentage percentage To remove the configured bandwidth percentage, use the no bandwidth-percentage command. Parameters percentage (Optional) Enter the bandwidth percentage. The percentage range is from 1 to 100% in units of 1%. Defaults none Command Modes QOS-POLICY-OUT-ETS Command History This guide is platform-specific.
clear ets counters Clear all ETS TLV counters on an interface. Syntax Parameters clear ets counters port-type slot/port[] port-type Enter the keywords port-type then the slot/port information. Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Usage Information Version Description 8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module. By default, iSCSI is enabled on the unit and the flow control is enabled on all of the interfaces. It is also acts as defaults when the link-level flow control is enabled on one or more interfaces. Enables priority flow control or enhance transmission selection on interface. Related Commands dcb enable — enable priority flow control or enhanced transmission selection on interface.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module. By default: • All 802.1p priorities are grouped in priority group 0.
If you enable the scheduler command for a QoS ETS output policy, no bandwidth percentage is assigned to the policy. Related Commands • scheduler — schedules the priority traffic in port queues. • bandwidth-percentage — bandwidth percentage allocated to the priority traffic in port queues. scheduler Configure the method used to schedule priority traffic in port queues. Syntax scheduler value To remove the configured priority schedule, use the no scheduler command.
Parameters port-type slot/ port[] ets Enter the port-type slot and port ETS information. {summary | detail} Enter the keyword summary for a summary list of results or enter the keyword detail for a full list of results. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
6 7 - - Oper status is init ETS DCBX Oper status is Down State Machine Type is Asymmetric Conf TLV Tx Status is enabled Reco TLV Tx Status is enabled 0 Input Conf TLV Pkts, 1955 Output Conf TLV Pkts, 0 Error Conf TLV Pkts 0 Input Reco TLV Pkts, 1955 Output Reco TLV Pkts, 0 Error Reco TLV Pkts Dell# show int te 1/3 ets de Interface TenGigabitEthernet 1/3 Max Supported TC Groups is 4 Number of Traffic Classes is 8 Admin mode is on Admin Parameters : -----------------Admin is enabled TC-grp Priority# Bandwi
Admin is enabled TC-grp Priority# Bandwidth TSA 0 0,1,2,3,4,5,6,7 100% ETS 1 0% ETS 2 0% ETS 3 0% ETS 4 0% ETS 5 0% ETS 6 0% ETS 7 0% ETS Priority# Bandwidth TSA 0 13% ETS 1 13% ETS 2 13% ETS 3 13% ETS 4 12% ETS 5 12% ETS 6 12% ETS 7 12% ETS Remote Parameters: ------------------Remote is disabled Local Parameters : -----------------Local is enabled TC-grp Priority# Bandwidth TSA 0 0,1,2,3,4,5,6,7 100% ETS 1 0% ETS 2 0% ETS 3 0% ETS 4 0% ETS 5 0% ETS 6 0% ETS 7 0% ETS Priority# Bandwidth TSA 0 13% ETS 1 13%
7 0% ETS Priority# 0 1 2 3 4 5 6 7 Remote Parameters: ------------------Remote is disabled Bandwidth 13% 13% 13% 13% 12% 12% 12% 12% TSA ETS ETS ETS ETS ETS ETS ETS ETS Bandwidth 100% 0% 0% 0% 0% 0% 0% 0% TSA ETS ETS ETS ETS ETS ETS ETS ETS Local Parameters : -----------------Local is enabled TC-grp Priority# 0 0,1,2,3,4,5,6,7 1 2 3 4 5 6 7 Priority# Bandwidth TSA 0 13% ETS 1 13% ETS 2 13% ETS 3 13% ETS 4 12% ETS 5 12% ETS 6 12% ETS 7 12% ETS Oper status is init Conf TLV Tx Status is disabled Traff
Version Description 8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module. Example (Summary) Del#show qos priority-groups priority-group ipc priority-list 4 set-pgid 2 show stack-unit stack-ports ets details Displays the ETS configuration applied to egress traffic on stacked ports, including ETS Operational mode on each unit and the configurated priority groups with dot1p priorities, bandwidth allocation, and scheduler type.
Admin Parameters: -------------------Admin is enabled TC-grp Priority# Bandwidth TSA -----------------------------------------------0 0,1,2,3,4,5,6,7 100% ETS 1 2 3 4 5 6 7 8 - DCBX Commands The following DCBX commands are supported on the Dell Networking OS. advertise dcbx-app-tlv Configure DCBX to send iSCSI TLV advertisements. S4810 Syntax advertise dcbx-app-tlv iscsi To disable DCBX iSCSI TLV advertisements, use the no advertise dcbx-app-tlv iscsi command.
Parameters {fcoe | iscsi} Enter the application priority TLVs, where: • fcoe: enables the advertisement of FCoE in application priority TLVs. • iscsi: enables the advertisement of iSCSI in application priority TLVs. Defaults Application priority TLVs are enabled to advertise FCoE and iSCSI. Command Modes PROTOCOL LLDP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module. You can configure the transmission of more than one TLV type at a time; for example: advertise dcbxtlv ets-conf ets-reco. You can enable ETS recommend TLVs (ets-reco) only if you enable ETS configuration TLVs (etsconf).
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module. DCBX requires that you enable LLDP to advertise DCBX TLVs to peers. Configure DCBX operation at the INTERFACE level on a switch or globally on the switch. To verify the DCBX configuration on a port, use the show interface dcbx detail command. dcbx version Configure the DCBX version used on the interface.
debug dcbx Enable DCBX debugging. Syntax debug dcbx {all | auto-detect-timer | config-exchng | fail | mgmt | resource | sem | tlv} To disable DCBX debugging, use the no debug dcbx command. Parameters {all | auto-detecttimer | configexchng | fail | mgmt | resource | sem | tlv} Enter the type of debugging, where: • all: enables all DCBX debugging operations. • auto-detect-timer: enables traces for DCBX auto-detect timers. • config-exchng: enables traces for DCBX configuration exchanges.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module.
slot/port[] Enter the slot/port number. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.2.(0.0) Down status messages added. 8.3.19.
Example Field Description Local DCBX Status: Sequence Number Sequence number transmitted in Control TLVs. Local DCBX Status: Acknowledgment Number Acknowledgement number transmitted in Control TLVs. Local DCBX Status: Protocol State Current operational state of the DCBX protocol: ACK or IN-SYNC. Peer DCBX Status: DCBX Operational Version DCBX version advertised in Control TLVs received from the peer device.
----------------DCBX Operational Version is 0 DCBX Max Version Supported is 0 Sequence Number: 2 Acknowledgment Number: 2 Protocol State: In-Sync Peer DCBX Status: ---------------DCBX Operational Version is 0 DCBX Max Version Supported is 255 Sequence Number: 2 Acknowledgment Number: 2 Total DCBX Frames transmitted 27 Total DCBX Frames received 6 Total DCBX Frame errors 0 Total DCBX Frames unrecognized 0 dcb-map Create a DCB map to configure priority flow control (PFC) and enhanced transmission selection (
priority-pgid Assign 802.1p priority traffic to a priority group in a DCB map. S4810 Syntax Parameters priority-pgid dot1p0_group-num dot1p1_group-num dot1p2_group-num dot1p3_group-num dot1p4_group-num dot1p5_group-num dot1p6_group-num dot1p7_group-num dot1p0_group-num Enter the priority group number for each 802.1p class of traffic in a DCB map.
pfc mode on Enable the PFC configuration on the port so that the priorities are included in DCBX negotiation with peer PFC devices. Syntax pfc mode on To disable the PFC configuration, use the no pfc mode on command. Defaults PFC mode is on. Command Modes DCB MAP Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Introduced on the MXL 10/40GbE Switch with the FC Flex IO module.
pfc {on | off} Defaults None Command Modes DCB MAP Command History Usage Information Configure whether priority-based flow control is enabled (on) or disabled (off) for port traffic in the priority group. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Introduced on the S4810, S6000 platforms. Use the dcb-map command to configure priority groups with PFC and/or ETS settings and apply them to Ethernet interfaces. Use the priority-pgid command to map 802.
Defaults None Command Modes CONFIGURATION Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Introduced on the S4810 and S6000 platforms. The dcb-map stack-unit all stack-ports all command overwrites any previous DCB maps applied to stack ports. show qos dcb-map Display the DCB parameters configured in a specified DCB map.
Example Field Description PFC PFC setting for the priority group: On (enabled) or Off. Priorities 802.1p priorities configured in the priority group. Dell# show qos dcb-map dcbmap2 State :Complete PfcMode:ON -------------------PG:0 TSA:ETS BW:50 PFC:OFF Priorities:0 1 2 4 5 6 7 PG:1 TSA:ETS Priorities:3 BW:50 PFC:ON dcb pfc-shared-buffer-size Configure the maximum amount of shared buffer size for PFC packets in kilobytes.
%ERROR: pfc shared buffer size configured cannot accommodate existing buffer requirement in the system. Example Dell(conf)#dcb pfc-shared-buffer-size 5000 dcb-buffer-threshold Configure the profile name for the DCB buffer threshold. This utility is supported on the S4810, S4820T, and S6000 platforms. S4810 Syntax dcb buffer—threshold profile-name Parameters profile-name Enter the name of the profile, which can be a string of up to 32 characters in length.
threshold-value Buffer limit at which the port sends the pause to peer in KB. Enter a number in the range of 0 to 7787. The default is 10 KB. resume-offset Buffer offset limit for resuming in KB threshold-value Buffer offset limit at which the port resumes the peer in KB. Enter a number in the range of 1 to 7787. The default is 10 KB. shared-thresholdweight Buffer shared threshold weight size Weightage of the priorities on the shared buffer size in the system. Enter a number in the range of 0 to 9.
acceptance of packets, and the buffer offset limit for resuming the acceptance of received packets. This method of configuration enables different peer-provided and administrative priorities to be set up because the intended queue is directly configured instead of determining the priority to queue mapping for local and remote parameters.
although a DCB input policy is present, the peer-provided priorities become effective for buffer configuration. This method of configuration provides an easy and flexible technique to accommodate both administratively-configured and peer-configured priorities.
Parameters dcb-bufferthreshold Configure the profile name for the DCB buffer threshold profile-name Enter the name of the profile, which can be a string of up to 32 characters in length. stack-unit all Enter the stack unit identification. Indicates the specific the stack unit or units. Entering all shows the status for all stacks. stack-port all Enter the port number of a port in a switch stack. Default None Command Modes CONFIGURATION mode Command History Version Description 9.3(0.
Example Field Description Name Name of the DCB buffer threshold profile Buffer threshold parameters Buffer size allocated for the PFC priority queue and the priority of the queue Dell#show qos dcb buffer-threshold Name : test1 Buffer threshold parameters: pfc priority 0 buffer-size 40 pfc priority 3 buffer-size 50 dcb pfc-total-buffer-size Configure the total buffer size for PFC in kilobytes. This utility is supported on the S6000 platform.
show running-config dcb-buffer-threshold Displays the DCB buffer threshold details in the running configuration. Syntax show running—config buffer-threshold Command Modes EXEC EXEC Privilege Command History Usage Information Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Introduced on the S6000 platform.
Field Description queue Number of the queue lossless Whether the queue is a lossy or lossless queue for wh threshold is configured buffer-size Ingress buffer size pause-threshold-value Buffer limit at which the port sends the pause to peer resume-threshold-value Buffer offset limit at which the port resumes the peer shared threshold weight Weightage of the priorities on the shared buffer size in system. dcb pfc-queues Configure the number of PFC queues.
Defaults Enable Command Modes INTERFACE Command History Usage Information Limitations 506 Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3 (0.1) Introduced on S6000, S4810, and S4820T. PFC and ETS are enabled by default on the interfaces when DCB is globally enabled (refer to dcb enable).
14 Debugging and Diagnostics The basic debugging and diagnostic commands are supported by the Dell Networking Operating System. This chapter contains the following sections: • Diagnostic and Monitoring Commands • Offline Diagnostic Commands • Hardware Commands Diagnostics and Monitoring Commands The following section describes the diagnostics and monitoring commands. For similar commands, refer to the Control and Monitoring chapter. logging coredump stack-unit Enable coredump on a stack.
Offline Diagnostic Commands The offline diagnostics test suite is useful for isolating faults and debugging hardware. While tests are running, Dell Networking OS results are saved as a text file (TestReport-SU-X.txt) in the flash directory. This show file command is available only on master and standby. Important Points to Remember • Offline diagnostics can only be run when the unit is offline. • You can only run offline diagnostics on a unit to which you are connected via the console.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.
The system reboots when the off-line diagnostics complete. This reboot is an automatic process. A warning message appears when the offline stack-unit command is implemented. Warning - Diagnostic execution will cause stack-unit to reboot after completion of diags. Proceed with Offline-Diags [confirm yes/no]:y Related Commands show environment (S-Series) — views the S-Series system component status (for example, temperature, voltage). online stack-unit Place a stack unit in the online state.
Hardware Commands These commands display information from a hardware sub-component or ASIC. clear hardware stack-unit Clear statistics from selected hardware components.
clear hardware system-flow Clear system-flow statistics from selected hardware components. Syntax clear hardware system-flow layer2 stack-unit number port-set 0–0 counters Parameters stack-unit number Enter the keywords stack-unit then a number to select a particular stack member and then enter one of the following command options to clear a specific collection of data. The range is from 0 to 11.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced this command. hardware watchdog To trigger a reboot and restart the system, set the watchdog timer. Syntax hardware watchdog stack-unit {<0-5> | all} Defaults Enabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. The unit numbers given are internal port numbers. show hardware layer3 Display Layer 3 ACL or QoS data for the selected stack member and stack member port-pipe.
show hardware stack-unit Display the data plane or management plane input and output statistics of the designated component of the designated stack member.
The following is a list of the Dell Networking OS version history for this command. Example (DataPlane) Version Description 9.8(0.0) Replaced the keyword port with interface. 9.7(0.0) Introduced on the S6000-ON. 9.2(0.2) Modified the drops keyword range, unit keyword range and added the buffer and cpu management statistics options. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.5 Added i2c statistics and sata-interfaces statistics. 8.3.11.
Example (PortStats) Dell#show hardware stack-unit 1 unit 0 ena/ speed/ link auto STP port link duplex scan neg? state pause ge0 down SW Yes Block ge1 !ena SW Yes Block ge2 !ena SW Yes Block ge3 !ena SW Yes Block ge4 !ena SW Yes Forward ge5 !ena SW Yes Forward ge6 !ena SW Yes Forward ge7 !ena SW Yes Forward ge8 !ena SW Yes Forward ge9 !ena SW Yes Forward ge10 !ena SW Yes Forward ge11 !ena SW Yes Forward ge12 !ena SW Yes Forward ge13 !ena SW Yes Forward ge14 !ena SW Yes Forward ge15 !ena SW Yes Forward ge16
0x0e700102 BCAST_BLOCK_MASK.ge0 = 0x00000000 0x0e701102 BCAST_BLOCK_MASK.ge1 = 0x00000000 0x0e702102 BCAST_BLOCK_MASK.ge2 = 0x00000000 0x0e703102 BCAST_BLOCK_MASK.ge3 = 0x00000000 0x0e704102 BCAST_BLOCK_MASK.ge4 = 0x00000000 0x0e705102 BCAST_BLOCK_MASK.ge5 = 0x00000000 0x0e706102 BCAST_BLOCK_MASK.ge6 = 0x00000000 0x0e707102 BCAST_BLOCK_MASK.ge7 = 0x00000000 0x0e708102 BCAST_BLOCK_MASK.ge8 = 0x00000000 0x0e709102 BCAST_BLOCK_MASK.ge9 = 0x00000000 0x0e70a102 BCAST_BLOCK_MASK.
RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX - Pause Control Frame Counter Oversized Frame Counter Jabber Frame Counter VLAN Tag Frame Counter Double VLAN Tag Frame Counter RUNT Frame Counter Fragment Counter VLAN Tagged Packets Ingress Dropped Packet MTU Check Error Frame Counter PFC Frame Priority 0 PFC Frame Priority 1 PFC Frame Priority 2 PFC
TX - Debug Counter 10 TX - Debug Counter 11 --------------------unit: 0 port: 61 (interface Fo 1/60) Description RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX TX TX TX TX TX TX TX TX TX 520 - IPV4 L3 Unicast Frame Counter IPV4 L3 Routed Multicast Packets IPV6 L3 Unicast Frame Counter IPV6 L3 Routed Multicast Packets Unicast Packet Counter 64 Byte Frame Counter 65 to 127 Byte Frame Counter 128 to 255 Byte
TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX Example (Details) - 4096 to 9216 Byte Frame Counter Good Packet Counter Packet/Frame Counter Unicast Frame Counter Multicast Frame Counter Broadcast Frame Counter Byte Counter Control Frame Counter Pause Control Frame Counter Oversized Frame Counter Jabber Counter VLAN Tag Frame Counter Double VLAN Tag Frame Counter RUNT Frame Counter Fragment Counter PFC Frame Priority 0 PFC Frame Priority 1 PFC Frame
The linkStatus of Front End Port 7 is FALSE The linkStatus of Front End Port 8 is FALSE The linkStatus of Front End Port 9 is FALSE The linkStatus of Front End Port 10 is FALSE The linkStatus of Front End Port 11 is FALSE The linkStatus of Front End Port 12 is FALSE The linkStatus of Front End Port 13 is FALSE The linkStatus of Front End Port 14 is FALSE The linkStatus of Front End Port 15 is FALSE The linkStatus of Front End Port 16 is FALSE The linkStatus of Front End Port 17 is FALSE The linkStatus of Fr
show processes cpu (S-Series) — displays the CPU usage information based on the processes running in an S-Series. show system (S-Series and Z-Series) — displays the current status of all the stack members or a specific member. show hardware buffer interface Display buffer statistics for a specific interface.
Example displaying queue range Dell#show hardware buffer interface tengigabitethernet 1/1 queue all buffer-info ----- Buffer Stats for Interface Te 1/1 Queue 0 ----Maximum Shared Limit: 29514 Default Packet Buffer allocate for the Queue: 8 Used Packet Buffer: 0 ----- Buffer Stats for Interface Te 1/1 Queue 1 ----Maximum Shared Limit: 29514 Default Packet Buffer allocate for the Queue: 8 Used Packet Buffer: 0 ----- Buffer Stats for Interface Te 1/1 Queue 2 ----Maximum Shared Limit: 29514 Default Packet Buff
interface interface Command Modes Enter any of the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. queue Enter the keyword queue after id for specific queue or keyword all. priority-group Enter the keyword priority-group followed by id for specific priority-group or keyword all.
--------------------------------------UCAST 10 0 Dell#show hardware buffer-stats-snapshot resource interface fortyGigE 0/0 queue ucast all Unit 0 unit: 0 port: 1 (interface Fo 0/0) --------------------------------------Q# TYPE Q# TOTAL BUFFERED CELLS --------------------------------------UCAST 0 0 UCAST 1 0 UCAST 2 0 UCAST 3 0 UCAST 4 0 UCAST 5 0 UCAST 6 0 UCAST 7 0 UCAST 8 0 UCAST 9 0 UCAST 10 0 UCAST 11 0 Example displaying egress queue-level snapshot for multicast packets for the specific interface Dell
4 5 6 7 0 0 0 0 0 0 0 0 show hardware counters interface Display the counter information for a specific interface. Syntax Parameters Defaults Command Modes Command History show hardware counters interface interface counters Enter the keywords counters to display counter value for the specified stackmember the port-pipe.
RX - Control Frame Counter RX - Pause Control Frame Counter RX - Oversized Frame Counter RX - Jabber Frame Counter RX - VLAN Tag Frame Counter RX - Double VLAN Tag Frame Counter RX - RUNT Frame Counter RX - Fragment Counter RX - VLAN Tagged Packets RX - Ingress Dropped Packet RX - MTU Check Error Frame Counter RX - PFC Frame Priority 0 RX - PFC Frame Priority 1 RX - PFC Frame Priority 2 RX - PFC Frame Priority 3 RX - PFC Frame Priority 4 RX - PFC Frame Priority 5 RX - PFC Frame Priority 6 RX - PFC Frame Pri
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.5 Added i2c statistics and sata-interfaces statistics. 8.3.11.4 Added user port information. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series.
Unknown Opcodes Internal Mac Receive Errors : 0 : 0 show hardware stack-unit buffer-stats-snapshot (Total Buffer Information) View the buffer statistics tracking resource information depending on the type of buffer information, such as device-level details, port-level counters, queue-based snapshots, or priority group-level snapshot in the egress and ingress direction of traffic.
Example Dell#show hardware stack-unit 1 buffer-stats-snapshot unit 3 resource interface all queue mcast 3 Unit 1 unit: 3 port: 1 (interface Fo 1/144) --------------------------------------Q# TYPE Q# TOTAL BUFFERED CELLS --------------------------------------MCAST 3 0 Unit 1 unit: 3 port: 5 (interface Fo 1/148) --------------------------------------Q# TYPE Q# TOTAL BUFFERED CELLS --------------------------------------MCAST 3 0 Unit 1 unit: 3 port: 9 (interface Fo 1/152) -------------------------------------
Parameters acl | qos For the selected stack member and stack member port-pipe, display which system flow entry the packet hits and what queue the packet takes as it dumps the raw system flow tables. stack-unit id Enter the keywords stack-unit to select a stack member ID. The range is from 0 to 11. port-set number [counters] Enter the keywords port-set with a port-pipe number. The range is from 0 to 0. (OPTIONAL) Enter the keyword counters to display hit counters for the selected ACL or QoS option.
1 25 Dell# Example L2BCASTPackets 0 param1=0(0x00)}, action={act=CosQCpuNew, param0=7(0x07), param1=0(0x00)}, action={act=CopyToCpu, param0=0(0x00), param1=0(0x00)}, action={act=UpdateCounter, param0=1(0x01), param1=0(0x00)}, meter=NULL, counter={idx=1, mode=0x01, entries=1} ############## FP Entry for redirecting LACP traffic to CPU Port ############ EID 2045: gid=1, slice=15, slice_idx=0x02, prio=0x7fd, flags=0x82, Installed tcam: color_indep=0, higig=0, higig_mask=0, KEY=0x00000000 00000000 00000000 0
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced this command.
15 Dynamic Host Configuration Protocol (DHCP) Dynamic host configuration protocol (DHCP) is an application layer protocol that dynamically assigns IP addresses and other configuration parameters to network end-stations (hosts) based on the configuration policies the network administrators determine. The Dell Networking operating system supports the basic DHCP commands on this platform.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series. Entering after the clear ip dhcp binding command clears all the IPs from the binding table. debug ip dhcp server Display FTOS debugging messages for DHCP. S4810 Syntax debug ip dhcp server [events | packets] Parameters events Enter the keyword events to display the DHCP state changes.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S4810, S4820T, S6000 and Z-Series. default-router Assign a default gateway to clients based on the address pool. S4810 Syntax Parameters default-router address [address2...address8] address Enter a list of routers that may be the default gateway for clients on the subnet. You may specify up to eight routers. List them in order of preference.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series.
Parameters name Give a name to the group of addresses in a pool. Defaults none Command Modes DHCP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
hardware-address For manual configurations, specify the client hardware address. S4810 Syntax hardware-address address Parameters address Enter the hardware address of the client. Defaults none Command Modes DHCP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series. lease Specify a lease time for the addresses in a pool. S4810 Syntax Parameters lease {days [hours] [minutes] | infinite} days Enter the number of days of the lease. The range is from 0 to 31. hours Enter the number of hours of the lease. The range is from 0 to 23. minutes Enter the number of minutes of the lease. The range is from 0 to 59.
Command Modes DHCP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.
network Specify the range of addresses in an address pool. S4810 Syntax network network /prefix-length Parameters network/ prefixlength Specify a range of addresses. Prefix-length range is from 17 to 31. Defaults none Command Modes DHCP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series. show ip dhcp binding Display the DHCP binding table. S4810 Syntax show ip dhcp binding Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series. show ip dhcp conflict Display the address conflict log. S4810 Syntax Parameters show ip dhcp conflict address address Display a particular conflict log entry.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series. Commands to Configure Secure DHCP DHCP, as defined by RFC 2131, provides no authentication or security mechanisms. Secure DHCP is a suite of features that protects networks that use dynamic address allocation from spoofing and attacks.
Defaults Command Modes Command History Disabled • INTERFACE • INTERFACE PORT-CHANNEL This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.6(0.0) Added the keywords discard-counters, interface, and the variable interface on the S4810, S4820T, S5000, S6000, Z9000, Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.
ip dhcp relay Enable Option 82. S4810 Syntax ip dhcp relay information-option [remote-id | trust-downstream] Parameters remote-id Configure the system to enable the remote-id string in option-82. trust-downstream Configure the system to trust Option 82 when it is received from the previous-hop router. Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific.
Usage Information Version Description 8.3.1.0 Introduced on the E-Series. 8.2.1.0 Introduced on the C-Series and S-Series on Layer 2 interfaces. 7.8.1.0 Introduced on the C-Series and S-Series on Layer 3 interfaces. When enabled, no learning takes place until you enable snooping on a VLAN. After disabling DHCP snooping, the binding table deletes and Option 82, IP Source Guard, and Dynamic ARP Inspection are disabled. Introduced in Dell Networking OS version 7.8.1.
Version Description 9.7(0.0) Introduced on the S4810, S4820T, S6000 and Z-Series. ip dhcp snooping binding Create a static entry in the DHCP binding table. S4810 Syntax Parameters Defaults Command Modes Command History [no] ip dhcp snooping binding mac address vlan-id vlan-id ip ip-address interface type slot/port lease number mac address Enter the keyword mac then the MAC address of the host to which the server is leasing the IP address.
Related Commands Version Description 7.8.1.0 Introduced on the C-Series and S-Series. show ip dhcp snooping — displays the contents of the DHCP binding table. IPv6 DHCP Snooping Binding Create a static DHCP snooping binding entry in the snooping database.
ip dhcp snooping database Delay writing the binding table for a specified time. S4810 Syntax Parameters ip dhcp snooping database write-delay minutes minutes The range is from 5 to 21600. Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Version Description 9.7(0.0) Introduced on the S4810, S4820T, S6000 and Z-Series. ip dhcp snooping database renew Renew the binding table. S4810 Syntax ip dhcp snooping database renew Defaults none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
ip dhcp snooping trust Configure an interface as trusted. S4810 Syntax [no] ip dhcp snooping trust Defaults Untrusted Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
vlan vlan-id Defaults Disabled Command Modes INTERFACE (OPTIONAL) SAV validates the source IP address along with the source VLAN ID against the DHCP snooping binding table. INTERFACE PORTCHANNEL Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
NOTE: Adds the VPN/VRF related sub-options into the relay agent information option(82). When DHCP broadcasts are forwarded by the relay agent from clients to DHCP server. Default Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.
Version Description 8.3.1.0 Introduced on the E-Series. 7.2.1.0 Introduced on the C-Series and S-Series. ipv6 dhcp snooping verify mac-address Syntax [no] ipv6 dhcp snooping verify mac-address To disable verify source mac-address against IPv6 DHCP packet MAC address, use the no ipv6 dhcp snooping verify mac-address command. Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific.
Usage Information Use this command on the interfaces where the DHCP clients are connected to forward the packets from clients to DHCP server and vice-versa. Example Dell(conf-if-te-1/12)#ip helper-address vrf jay 10.0.0.2 ipv6 helper-address Configures the ipv6 DHCP helper addresses without VRF. Syntax [no] ipv6 helper-address ipv6-address To delete the ipv6 helper address, use the [no] ipv6 helper-address ipv6-address command.
interface interface (OPTIONAL) Specifies an interface to show the discard counters. Enter any of the following keywords and slot/port or number information: Defaults • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128.
permit host 0.0.0.0 host 00:00:00:00:00:00 count (0 packets) permit vlan 10 host 1.1.1.1 host 00:00:00:00:01:01 count (0 packets) permit vlan 10 host 1.1.1.2 host 00:00:00:00:01:02 count (0 packets) permit vlan 10 host 1.1.1.3 host 00:00:00:00:01:03 count (0 packets) ipmac-vlan sav access-list on Port-channel 10 on stack-unit 1 Total cam count 5 permit host 0.0.0.0 host 00:00:00:00:00:00 count (0 packets) permit vlan 10 host 1.1.1.1 host 00:00:00:00:01:01 count (0 packets) permit vlan 10 host 1.1.1.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S4810, S4820T, S6000 and Z-Series. Dell#show ipv6 dhcp snooping IPv6 DHCP Snooping IPv6 DHCP Snooping Mac Verification : Enabled. : Disabled.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Introduced on the S-Series and Z-Series. Usage Information Use this command to associate name server IP addresses to a specific VRF.
ip domain-list Adds a domain name to the DNS list. This domain name is appended to incomplete host names in DNS requests corresponding to a specific VRF. S4810 Syntax ip domain-list [vrf vrf-name] name To remove a domain name from DNS list, use the no ip domain-list [vrf vrf-name] name command. Parameters vrf vrf-name (Optional) Enter the key word vrf and then the name of the VRF to add a domain name to the DNS list corresponding to that VRF.
ip-address Enter the IP address of the name server in dotted decimal format. Defaults None Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Introduced on the S-Series and Z-Series.
16 Equal Cost Multi-Path (ECMP) Equal cost multi-path (ECMP) is supported on the Dell Networking OS. ecmp-group Provides a mechanism to monitor traffic distribution on an ECMP link bundle. A system log is generated when the standard deviation of traffic distribution on a member link exceeds a defined threshold. S4810 Syntax ecmp-group {ecmp-group-id interface interface | link-bundle-monitor} To remove the selected interface, use the ecmp-group no interface command.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.10.0 Introduced on the S4810. Using CONFIGURATION mode, create an ECMP group ID. You can then assign interfaces to the ECMP group using CONFIGURATION ECMP-GROUP mode. You can also enable on the port-channel configuration using the CONFIGURATION ECMP-GROUP command mode. hash-algorithm Changes the hash algorithm used to distribute traffic flows across a Port Channel. The ECMP and LAG options are supported on the Z-Series.
hg {crc16 | crc16cc | crc32MSB | crc32LSB | xor1 | xor2 | xor4 | xor8 | xor16} stack-unit stack-unit-number | port-set port-pipe • xor8: Use CRC16_BISYNC_AND_XOR8 — Upper 8 bits of CRC16-BISYNC and lower 8 bits of xor8 • xor16: Use CR16 — 16 bit XOR Z-Series only: Enter the keyword hg then one of the following options: • crc16: Use CRC16_BISYNC — 16 bit CRC16-bisync polynomial (default) • crc16cc: Use CRC16_CCITT — 16 bit CRC16 using CRC16-CCITT polynomial • crc32MSB: Use CRC32_UPPER — MSB 16 bits
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.10.0 Introduced on the S4810. 8.1.1.
hash-algorithm ecmp Change the hash algorithm used to distribute traffic flows across an ECMP (equal-cost multipath routing) group. S4810 Term heading Description heading Syntax hash-algorithm ecmp {crc-upper} | {dest-ip} | {lsb} To return to the default hash algorithm, use the no hash-algorithm ecmp command. Parameters Defaults crc-upper Uses the upper 32 bits of the key for the hash computation. The default is crclower. dest-ip Uses the destination IP for ECMP hashing. The default is enabled.
hash-algorithm seed Select the seed value for the ECMP, LAG, and NH hashing algorithm. S4810 Syntax Parameters hash-algorithm seed value [stack-unitslot/port] [port-set number] seed value Enter the keyword seed then the seed value. The range is from 0 to 2,147,483,646. stack–unit slot/port Enter the keyword stack-unit then the slot/port number. The range is from 0 to 11. port-set number Enter the keyword port-set then the port-pipe number. The value is 0.
ip ecmp-group Enable and specify the maximum number of ecmp that the L3 CAM hold for a route, By default, when maximum paths are not configured, the CAM can hold a maximum of 16 ecmp per route. S4810 Syntax ip ecmp-group {maximum-paths | {number} {path-fallback} To negate a command, use the no ip ecmp-group maximum-paths {number} command. Parameters maximum-paths Specify the maximum number of ECMP for a route. The range is 2 to 64. path-fallback Use the keywords path-fallback to enable this feature.
If disabled, the CLI would inform the FIB to re-program the destination prefix paths with no weights or regular ECMP.
To exit from ecmp group mode, use the exit command. Parameters percent Indicate the threshold value when traffic distribution starts being monitored on an ECMP link bundle. The range is from 1 to 90%. The default is 60%. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
show link-bundle distribution Display the link-bundle distribution for the interfaces in the bundle, type of bundle (LAG or ECMP), and the most recently calculated interface utilization (either bytes per second rate or maximum rate) for each interface. S4810 Syntax show link-bundle-distribution Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
17 FIPS Cryptography To configure federal information processing standards (FIPS) cryptography, use the following commands: fips mode enable Enable the FIPS cryptography mode on the platform. Syntax [no] fips mode enable To disable the FIPS cryptography mode, use the no fips mode enable command.
Dell#show fips status FIPS Mode : Enabled Dell# Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.1(0.0) Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810.
SSH server version : v2. SSH server vrf : default. SSH server ciphers : 3des-cbc,aes128-cbc,aes192-cbc,aes256cbc,aes128-ctr,aes192-ctr,aes256-ctr. SSH server macs : hmac-sha1-96. SSH server kex algorithms : diffie-hellman-group14-sha1. Password Authentication : enabled. Hostbased Authentication : disabled. RSA Authentication : disabled. Vty Encryption HMAC Remote IP 0 3des-cbc hmac-sha1-96 10.1.20.48 1 3des-cbc hmac-sha1-96 10.1.20.48 With FIPS Mode disabled: Dell#show ip ssh SSH server : enabled.
• aes128–ctr: Force ssh to use the aes256–cbc encryption cipher. • aes192–ctr: Force ssh to use the aes128–cbc encryption cipher. • aes256–cbc: Force ssh to use the aes256–cbc encryption cipher. -l username (OPTIONAL) Enter the keyword —l then the user name used in this SSH session. The default is the user name of the user associated with the terminal. -m HMAC algorithm Enter one of the following HMAC algorithms to use. (For v2 clients only.
show ip ssh clientpub-keys Usage Information Display the client-public keys. Dell Networking OS supports both inbound and outbound SSH sessions using IPv4 or IPv6 addressing. Inbound SSH supports accessing the system through the management interface as well as through a physical Layer 3 interface. NOTE: Some of the parameters in this command require licensing to access. For more information, contact your Dell Networking representative. Example If FIPS mode is not enabled: Dell#ssh 10.10.10.
18 FIP Snooping To enable the FCoE Transit feature and configure FIP snooping, use the following Dell Networking Operating System commands on the S4810 platform. In a converged Ethernet network, a switch can operate as an intermediate Ethernet bridge to snoop on FIP packets during the login process on Fibre Channel over Ethernet (FCoE) forwarders (FCFs).
clear fip-snooping statistics Clears the statistics on the FIP packets snooped on all VLANs, a specified VLAN, or a specified port interface. S4810 Syntax clear fip-snooping statistics [interface vlan vlan-id | interface fortyGigEport-type port/slot | interface port-channel port-channel-number] Parameters vlan-id Enter the VLAN ID of the FIP packet statistics to be cleared. port-type port/slot Enter the port-type and slot number of the FIP packet statistics to be cleared.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the Z9500 and S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. debug fip snooping rx Enable debugging for FIP snooping receive-specific packets.
Version Description 9.7(0.0) Introduced on the Z9500 and S6000-ON. 9.2(0.2) Introduced on the S4810 and S4820T. Added the receive parameters packettype and interfaces and their options. feature fip-snooping Enable FCoE transit and FIP snooping on a switch. S4810 Syntax feature fip-snooping To disable the FCoE transit feature, use the no feature fip-snooping command. Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the Z9500 and S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. The maximum number of FCFs supported per FIP snooping-enabled VLAN is four.
fip-snooping max-sessions-per-enodemac Configure the maximum session limit per ENode MAC address. S4810 Syntax fip-snooping max—sessions—per—enode—mac max-sessions-value To return the configured maximum sessions to the default value, use the no fip-snooping max— sessions—per—enode—mac command. Parameters max-sessions-value Enter the maximum number of sessions allowed per ENode MAC address. The range is from 1 to 64.
fip-snooping port-mode fcoe-trusted Configure the port for bridge-to-bridge links. S4810 Syntax fip-snooping port-mode fcoe-trusted To remove the bridge-to-bridge link configuration from the port, use the no fip-snooping port-mode fcoe-trusted command. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Example Dell# show fip-snooping config FIP Snooping Feature enabled Status: Enabled FIP Snooping Global enabled Status: Enabled Global FC-MAP Value: 0X0EFC00 FIP Snooping enabled VLANs VLAN Enabled FC-MAP ----------------100 TRUE 0X0EFC00 show fip-snooping enode Display information on the ENodes in FIP-snooped sessions, including the ENode interface and MAC address, FCF MAC address, VLAN ID and FC-ID.
--------- --------------- ------- ---- ----d4:ae:52:1b:e3:cd Te 1/11 54:7f:ee:37:34:40 100 62:00:11 show fip-snooping fcf Display information on the FCFs in FIP-snooped sessions, including the FCF interface and MAC address, FCF interface, VLAN ID, FC-MAP value, FKA advertisement period, and number of ENodes connected. S4810 Syntax Parameters Command Modes Command History show fip-snooping fcf [fcf-mac-address] fcf-mac-address • EXEC • EXEC Privilege Enter the MAC address of the FCF to display.
show fip-snooping statistics Display statistics on the FIP packets snooped on all interfaces, including VLANs, physical ports, and port channels. S4810 Syntax show fip-snooping statistics [interface vlan vlan-id | interface port-type port/slot | interface port-channel port-channel-number] Parameters Command Modes Command History vlan-id Enter the VLAN ID of the FIP packet statistics displays. port-type port/slot Enter the port-type and slot number of the FIP packet statistics displays.
Example Field Description Number of VN Port Keep Alives Number of FIP-snoop VN port (Virtual N-port) keep-alive frames received on the interface Number of Multicast Discovery Advertisements Number of FIP-snoop multicast discovery advertisements received on the interface. Number of Unicast Discovery Advertisements Number of FIP-snoop unicast discovery advertisements received on the interface. Number of FLOGI Accepts Number of FIP FLOGI accept frames received on the interface.
Number of Session failures due to Hardware Config :0 Dell(conf)# Dell# show fip-snooping statistics int tengigabitethernet 1/11 Number of Vlan Requests :1 Number of Vlan Notifications :0 Number of Multicast Discovery Solicits :1 Number of Unicast Discovery Solicits :0 Number of FLOGI :1 Number of FDISC :16 Number of FLOGO :0 Number of Enode Keep Alive :4416 Number of VN Port Keep Alive :3136 Number of Multicast Discovery Advertisement :0 Number of Unicast Discovery Advertisement :0 Number of FLOGI Accepts :
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the Z9500 and S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810.
show fips status Display the FIPs status on the platform. S4810 Syntax show fips status Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. 594 FIP Snooping Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.12.
19 Force10 Resilient Ring Protocol (FRRP) Force10 resilient ring protocol (FRRP) is supported on Dell Networking OS. FRRP is a proprietary protocol for that offers fast convergence in a Layer 2 network without having to run the spanning tree protocol (STP). The resilient ring protocol is an efficient protocol that transmits a high-speed token across a ring to verify the link status. All the intelligence is contained in the master node with practically no intelligence required of the transit mode.
Usage Information Example Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series. 7.5.1.0 Introduced. Executing this command without the optional ring-id command clears the statistics counters on all the available rings. Dell Networking OS requires a command line confirmation before the command executes.
Command Modes CONFIGURATION (conf-frrp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Version Description 8.2.1.0 Introduced on the C-Series. 7.4.1.0 Introduced. disable Disable the resilient ring protocol. S4810 Syntax disable To enable the Resilient Ring Protocol, use the no disable command. Defaults Disabled Command Modes CONFIGURATION (conf-frrp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Parameters primary interface secondary interface control-vlan vlan-id Enter the keyword primary to configure the primary interface then one of the following interfaces and slot/port information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a port channel interface, enter the keywords port-channel then a number.
member-vlan Specify the member VLAN identification numbers. S4810 Syntax member-vlan {vlan-range} To return to the default, use the no member-vlan [vlan-range] command. Parameters vlan-range Enter the member VLANs using VLAN IDs (separated by commas), a range of VLAN IDs (separated by a hyphen), a single VLAN ID, or a combination. For example: VLAN IDs (comma-separated): 3, 4, 6. Range (hyphen-separated): 5-10. Combination: 3, 4, 5-10, 8.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series. 7.4.1.
Usage Information This command places you into the resilient ring protocol. After executing this command, the command line prompt changes to conf-frrp. show frrp Display the resilient ring protocol configuration. S4810 Syntax show frrp [ring-id [summary]] | [summary] Parameters ring-id Enter the ring identification number. The range is from 1 to 255 summary (OPTIONAL) Enter the keyword summary to view just a summarized version of the Ring configuration.
• The number of state change counters Example (Summary) Dell#show frrp summary Ring-ID State Mode Ctrl_Vlan Member_Vlans ---------------------------------------------2 UP Master 2 11-20, 25,27-30 31 UP Transit 31 40-41 50 Down Transit 50 32 Dell# Example (1) Dell#show frrp 1 Ring protocol 1 is in Master mode Ring Protocol Interface: Primary : TenGigabitEthernet 1/16 State: Forwarding Secondary: Port-channel 100 State: Blocking Control Vlan: 1 Ring protocol Timers: Hello-Interval 50 msec Dead-Interval 150
NOTE: The configured dead interval must be at least three times the hello interval. Defaults • 500 ms for hello-interval milliseconds • 1500 ms for dead-intervalmilliseconds Command Modes CONFIGURATION (conf-frrp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
20 GARP VLAN Registration (GVRP) The Dell Networking operating system supports the basic GVRP commands on the Dell Networking OS. The generic attribute registration protocol (GARP) mechanism allows the configuration of a GARP participant to propagate through a network quickly. A GARP participant registers or de-registers its attributes with other participants by making or withdrawing declarations of attributes.
clear gvrp statistics Clear GVRP statistics on an interface. S4810 Syntax clear gvrp statistics interface interface Parameters interface interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a port channel interface, enter the keywords port-channel then a number.
To disable debugging, use the no debug gvrp {config | events | pdu} command. Parameters config Enter the keyword config to enable debugging on the GVRP configuration. event Enter the keyword event to enable debugging on the JOIN/LEAVE events. pdu Enter the keyword pdu then one of the following Interface keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on C-Series, E-Series, and S-Series gvrp enable — enables GVRP on physical interfaces and LAGs. protocol gvrp — access GVRP protocol.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
Related Commands Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on C-Series, E-Series, and S-Series disable — globally disables GVRP. gvrp registration Configure the GVRP register type. S4810 Syntax gvrp registration {fixed | normal | forbidden} To return to the default, use the gvrp register normal command.
Usage Information Fixed registration prevents an interface, configured using the command line, to belong to a VLAN (static configuration) from being unconfigured when it receives a Leave message. Therefore, Registration mode on that interface is fixed. Normal registration is the default registration. The port’s membership in the VLAN depends on GVRP. The interface becomes a member of a VLAN after learning about the VLAN through GVRP.
show config Display the global GVRP configuration. S4810 Syntax show config Command Modes CONFIGURATION-GVRP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on C-Series, E-Series, and S-Series Example Dell#show garp timers GARP Timers Value (milliseconds) ---------------------------------------Join Timer 200 Leave Timer 600 LeaveAll Timer 10000 Dell# Related Commands garp timers — sets the intervals (in milliseconds) for sending GARP messages.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on C-Series, E-Series, and S-Series Usage Information If no ports are GVRP participants, the message output changes from GVRP Participants running on to GVRP Participants running on no ports. Example R3#show gvrp brief GVRP Feature is currently enabled.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 7.6.1.
21 High Availability (HA) High availability (HA) in the Dell Networking operating software is configuration synchronization to minimize recovery time in the event of a route processor module (RPM) failure. The feature is available on Dell Networking OS. In general, a protocol is defined as “hitless” in the context of an RPM failure/failover and not failures of a line card, SFM, or power module. A protocol is defined as hitless if an RPM failover has no impact on the protocol.
There is no need to reload or reboot the system when you insert the patch. The In-Service Modular patch replaces the existing process code. After installation is complete, the system executes the patch code as though it was always there. Related Commands show patch — displays the system patches loaded with the in-service modular hot fix command. process restartable Enable a process to be restarted. Restartability is subject to a maximum restart limit.
redundancy auto-failover-limit Specify an auto-failover limit for RPMs. When a non-recoverable fatal error is detected, an automatic RPM failover occurs. This command does not affect user-initiated (manual) failovers. S4810 Syntax redundancy auto-failover-limit [count number [period minutes] | period minutes]] To disable the auto-failover limit control, use the no redundancy auto-failover-limit command.
redundancy disable-auto-reboot Prevent the system from auto-rebooting the failed module. S4810 Syntax redundancy disable-auto-reboot stack-unit [0–11 | members} [rpm| card number | all] To return to the default, use the no redundancy disable-auto-reboot stack-unit rpm command. Parameters rpm Enter the keyword rpm to disable auto-reboot of the failed RPM. stack-unit Enter the keyword stack-unit then the stack-unit ID number. Default Disabled (that is, the failed module is automatically rebooted).
Parameters stack-unit Enter the keyword stack-unit then the stack-unit ID number. Default Not configured. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.2(0.0) Introduced on the M I/O Aggregator.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.5.1.0 Introduced on the C-Series. 7.6.1.0 Introduced on the E-Series. redundancy protocol Enable hitless protocols. S4810 Syntax redundancy protocol {lacp | xstp} To disable a hitless protocol, use the no redundancy protocol {lacp | xstp} command. Parameters lacp Enter the keyword lacp to make LACP hitless.
redundancy reset-counter Reset failover counter and timestamp information displayed in the show redundancy command. S4810 Syntax redundancy reset-counter Default Not configured. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 8.3.19.
secondary RPM. When you execute this command, the logical SFM on the standby RPM is immediately taken offline and the SFM state is set as “standby”. NOTE: This command could affect traffic when taking the secondary SFM offline. Example Dell#show sfm all Switch Fabric State: up -- Switch Fabric Modules -Slot Status -------------------------------------0 active 1 active Dell#configure Dell(conf)#redundancy sfm standby Taking secondary SFM offline...
The following is a list of the Dell Networking OS version history for this command. Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.5.1.0 Introduced on the C-Series. 7.6.1.0 Introduced on the E-Series. show patch Display the system patches loaded with the In-Service Modular Hot Fix command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced on the E-Series.
Usage Information Version Description 7.5.1.0 Introduced on the C-Series. 7.6.1.0 Introduced on the E-Series. The following describes the show redundancy command shown in the following example. Field Description RPM Status Displays the following information: • Slot number of the RPM. • Whether the RPM is Primary or Standby. • The state of the RPM: Active, Standby, Booting, or Offline. • Whether the link to the second RPM is up or down.
-----------------------------------------------RPM Slot ID: 1 RPM Redundancy Role: Primary RPM State: Active RPM SW Version: 7.5.1.0 Link to Peer: Up -- PEER RPM Status ------------------------------------------------RPM State: Standby RPM SW Version: 7.5.1.
22 ICMP Message Types This chapter lists and describes the possible ICMP message type resulting from a ping. The first three columns list the possible symbol or type/code. For example, you would receive a ! or 03 as an echo reply from your ping. ICMP Messages and Their Definitions. Symbol Type Code . 0 U 3 4 3 Error ICMP Message Types echo reply . destination unreachable: 0 network unreachable . 1 host unreachable . 2 protocol unreachable . 3 port unreachable .
Symbol & Type Code Description Query 8 0 echo request . 9 0 router advertisement . 10 0 router solicitation . 11 Error time exceeded: 0 time-to-live equals 0 during transit . 1 time-to-live equals 0 during reassembly . 12 parameter problem: 1 IP header bad (catchall error) . 2 required option missing . 13 0 timestamp request . 14 0 timestamp reply . 15 0 information request (obsolete) . 16 0 information reply (obsolete) . 17 0 address mask request .
23 Internet Group Management Protocol (IGMP) The IGMP commands are supported by the Dell Networking operating software on the Dell Networking OS. This chapter contains the following sections: • IGMP Commands • IGMP Snooping Commands IGMP Commands Dell Networking OS supports IGMPv1/v2/v3 and is compliant with RFC-3376.
• For a port channel interface, enter the keywords port-channel then a number. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF.
• For a port channel interface, enter the keywords port-channel then a number. Defaults Disabled. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series and S-Series. 7.6.1.0 Introduced on E-Series. The access list accepted is an extended ACL. To block IGMP reports from hosts, on a per-interface basis based on the group address and source address that you specify in the access list, use this feature. ip igmp immediate-leave Enable IGMP immediate leave.
ip igmp last-member-query-interval Change the last member query interval, which is the Max Response Time inserted into Group-Specific Queries sent in response to Leave Group messages. This interval is also the interval between Group-Specific Query messages. S4810 Syntax ip igmp last-member-query-interval milliseconds To return to the default value, use the no ip igmp last-member-query-interval command. Parameters milliseconds Enter the number of milliseconds as the interval.
Parameters seconds Enter the number of seconds between queries sent out. The range is from 1 to 18000. The default is 60 seconds. Defaults 60 seconds Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
Defaults 10 seconds Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF and Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 7.5.1.0 Introduced on the E-Series. show ip igmp groups View the IGMP groups. S4810 Syntax show ip igmp [vrf vrf-name] groups [group-address [detail] | detail | interface [group-address [detail]]] Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to configure this setting on that VRF.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series and C-Series. 7.5.1.0 Expanded to support the detail option. E-Series legacy command. Usage Information This command displays the IGMP database, including configured entries for either all groups on all interfaces, all groups on specific interfaces, or specific groups on specific interfaces.
Example (Details) Dell#show ip igmp group details Interface Vlan 20 Group 232.1.1.5 Uptime 00:11:22 Expires Never Router mode INCLUDE Last reporter 35.0.0.2 Group source list Source address Expires 65.0.0.1 00:01:22 65.0.0.2 00:01:22 65.0.0.3 00:01:22 65.0.0.4 00:01:22 65.0.0.5 00:01:22 show ip igmp interface View information on the interfaces participating in IGMP.
Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command. Usage Information IGMP commands accept only non-VLAN interfaces — specifying VLAN does not yield results. The show ip igmp interface command does not display information corresponding to the loop-back interfaces.
show ip igmp ssm-map Display is a list of groups that are currently in the IGMP group table and contain SSM mapped sources. S4810 Syntax show ip igmp [vrf vrf-name] ssm-map [group] Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to configure this setting on that VRF. NOTE: Applies to specific VRF if input is provided, else applies to Default VRF.
IGMP Snooping Commands Dell Networking OS supports IGMP Snooping version 2 and 3 on all Dell Networking systems. Important Points to Remember for IGMP Snooping • Dell Networking OS supports version 1, version 2, and version 3 hosts. • Dell Networking OS IGMP snooping implementation is based on IP multicast address (not based on Layer 2 multicast mac address) and the IGMP snooping entries are in Layer 3 flow table not in Layer 2 forwarding information base (FIB).
• For a port channel interface, enter the keywords port-channel then a number. Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on S-Series and Z–Series.
ip igmp snooping enable Enable IGMP snooping on all or a single VLAN. This command is the master on/off switch to enable IGMP snooping. Syntax ip igmp snooping enable To disable IGMP snooping, use the no ip igmp snooping enable command. Defaults Command Modes Command History Disabled. • CONFIGURATION • INTERFACE VLAN This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 8.3.19.
Version Description 8.2.1.0 Introduced on the C-Seris and S-Series. 7.7.1.0 Introduced on the E-Series. E-Series legacy command Usage Information On the C-Series and S-Series, unregistered multicast data traffic drops when you disable flooding; they do not forward the packets to multicast router ports. On the C-Series and S-Series, in order to disable Layer 2 multicast flooding, disable Layer 3 multicast (no ip multicast-routing).
Usage Information This last-member-query-interval is also the interval between successive Group-Specific Query messages. To change the last-member-query interval, use this command. ip igmp snooping mrouter Statically configure a VLAN member port as a multicast router interface. S4810 Syntax ip igmp snooping mrouter interface interface To delete a specific multicast router interface, use the no igmp snooping mrouter interface interface command.
ip igmp snooping querier Enable IGMP querier processing for the VLAN interface. S4810 Syntax ip igmp snooping querier To disable IGMP querier processing for the VLAN interface, use the no ip igmp snooping querier command. Defaults Not configured. Command Modes INTERFACE VLAN — (conf-if-vl-n) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
interface detail Command Modes Command History • EXEC • EXEC Privilege (OPTIONAL) Enter the interface type and slot/port information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383.
show ip igmp snooping mrouter Display multicast router interfaces. S4810 Syntax Parameters Command Modes Command History show ip igmp snooping mrouter [vlan number] vlan number • EXEC • EXEC Privilege Enter the keyword vlan then the vlan number. The range is from 1 to 4094. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
24 Interfaces The commands in this chapter are supported by Dell Networking operating software on the S4810 platform. This chapter contains the following sections: • Basic Interface Commands • Port Channel Commands • Time Domain Reflectometer (TDR) • UDP Broadcast Basic Interface Commands The following commands are for Physical, Loopback, and Null interfaces.
vrrp [[ipv6] vrid] (OPTIONAL) Enter the keyword vrrp to clear the counters of all VRRP groups. To clear the counters of VRRP groups on all IPv6 interfaces, enter ipv6. To clear the counters of a specified group, enter a VRID number from 1 to 255. learning-limit (OPTIONAL) Enter the keywords learning-limit to clear unknown source address (SA) drop counters when MAC learning limit is configured on the interface. vlan vlan-id Enter the keyword vlan followed by the interface VLAN number.
clear dampening Clear the dampening counters on all the interfaces or just the specified interface. S4810 Syntax clear dampening [interface] Parameters interface (OPTIONAL) Enter any of the following keywords and slot/port or number to clear counters from a specified interface: • For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
dampening — configures dampening on an interface. dampening Configure dampening on an interface. S4810 Syntax Parameters dampening [[[[half-life] [reuse-threshold]] [suppress-threshold]] [maxsuppress-time]] half-life Enter the number of seconds after which the penalty is decreased. The penalty decreases half after the half-life period expires. The range is from 1 to 30 seconds. The default is 5 seconds.
• suppress-threshold should be greater than reuse-threshold • max-suppress-time should be at least 4 times half-life NOTE: You cannot apply dampening on an interface that is monitoring traffic for other interfaces. Example Dell(conf-if-te-1/10)#dampening 20 800 4500 120 Dell(conf-if-te-1/10)# Related Commands clear dampening — clears the dampening counters on all the interfaces or just the specified interface. show interfaces dampening — displays interface dampening information.
• Entering a text string after the description command overwrites any previous text string that you previously configured as the description. • The shutdown and description commands are the only commands that you can configure on an interface that is a member of a port-channel. • Use the show interfaces description command to display descriptions configured for each interface. duplex (10/100 Interfaces) Configure duplex mode on any physical interfaces where the speed is set to 10/100.
flowcontrol Control how the system responds to and generates 802.3x pause frames on 10 Gig ports. Syntax flowcontrol rx {off | on} tx {off | on} [negotiate] Parameters rx on Enter the keywords rx on to process the received flow control frames on this port. This is the default value for the receive side. rx off Enter the keywords rx off to ignore the received flow control frames on this port.
Important Points to Remember • Do not enable tx pause when buffer carving is enabled. For information and assistance, consult Dell Networking TA • The only configuration applicable to half duplex ports is rx off tx off. The following error is returned: Can’t configure flowcontrol when half duplex is configure, config ignored • Half duplex cannot be configured when the flow control configuration is on (default is rx on tx on).
Related Commands off off on off on off off off off on on on off off on on off off on on off on on on off off on on off off on on off off on on off off on on show running-config — displays the flow configuration parameters (non-default values only). show interfaces — displays the negotiated flow control parameters. interface Configure a physical interface on the switch.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.4.1.0 Introduced You cannot delete a physical interface.
Parameters interface, interface,... Enter the keywords interface group and one of the interfaces — slot/port or VLAN number. Select the range of interfaces for bulk configuration. Spaces are not required between the commas. Comma-separated ranges can include VLANs and physical interfaces. Enter the member VLANs using VLAN IDs (separated by commas), a range of VLAN IDs (separated by a hyphen), a single VLAN ID, or a combination. For example: VLAN IDs (comma-separated): 3, 4, 6.
interface loopback Configure a Loopback interface. S4810 Syntax interface loopback number To remove a loopback interface, use the no interface loopback number command. Parameters number Enter a number as the interface number. The range is from 0 to 16383. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Parameters slot/port Enter the keyword ManagementEthernet, then the slot number (0 or 1) and port number zero (0). Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.
required between the commas. The ranges can include VLANs, port-channels, and physical interfaces. • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094.
• If overlapping port ranges are specified, the port range is extended to the smallest start port and the biggest end port.
interface range macro (define) — defines a macro for an interface-range. interface range macro (define) Defines a macro for an interface range and then saves the macro in the running configuration. S4810 Syntax define interface range macro name interface , interface , ... Parameters name Enter up to 16 characters for the macro name. interface, interface,... Enter the keywords interface range and one of the interfaces — slot/port, port-channel, or VLAN number.
Example (Single Range) Version Description pre-Version 6.1.1.0 Introduced on the E-Series. This example shows how to define an interface range macro named test. Execute the show runningconfig command to display the macro definition.
Example (Single Range) This example shows the macro named test that was defined earlier. Dell(config)#interface range macro test Dell(config-if-range-te-1/1-3,te-5/1-47,te-13/1-89)# Dell Related Commands interface range — configures a range of command (bulk configuration). interface range macro (define) — defines a macro for an interface range (bulk configuration). interface vlan Configure a VLAN. You can configure up to 4094 VLANs.
If OpenFlow VLANs are configured on the switch, spanning-tree protocols cannot be enabled simultaneously. Example (Single Range) Dell(conf)#int vlan 3 Dell(conf-if-vl-3)# Related Commands interface — configures a physical interface. interface loopback — configures a loopback interface. interface null — configures a null interface. interface port-channel — configures a port channel group. show vlan — displays the current VLAN configuration on the switch. shutdown — disables/enables the VLAN.
• interface loopback — configures a loopback interface. • interface null — configures a null interface. • interface port-channel — configures a port channel group. keepalive Send keepalive packets periodically to keep an interface alive when it is not transmitting data. S4810 Syntax keepalive To stop sending keepalive packets, use the no keepalive command. Defaults Enabled. Command Modes INTERFACE Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.0 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.
no Negate a command or set its defaults show Show autoneg configuration information Dell(conf-if-autoneg)#mode ? forced-master Force port to master mode forced-slave Force port to slave mode Dell(conf-if-autoneg)# Example (Configured) Dell#show interfaces configured TenGigabitEthernet 13/18 is up, line protocol is up Hardware is Force10Eth, address is 00:01:e8:05:f7:fc Current address is 00:01:e8:05:f7:fc Interface index is 474791997 Internet address is 1.1.1.
monitor interface Monitor counters on a single interface or all interfaces on a line card. The screen is refreshed every five seconds and the CLI prompt disappears. Syntax monitor interface [interface] To disable monitoring and return to the CLI prompt, press the q key.
Example (Single Interface) Key Description systest-3 Displays the host name assigned to the system. monitor time Displays the amount of time since the monitor interface command was entered. time Displays the amount of time the chassis is up (since last reboot). m Change the view from a single interface to all interfaces on the line card or visaversa. c Refresh the view. b Change the counters displayed from Packets on the interface to Bytes.
Te 0/2 Up 61512 52 66160 42 Te 0/3 Up 63086 20 9405888 24 Te 0/4 Up 14697471418 2661481 13392989657 2661385 Te 0/5 Up 3759 3 161959604 832816 Te 0/6 Up 4070 3 8680346 5 Te 0/7 Up 61934 34 138734357 72 Te 0/8 Up 61427 1 59960 1 Te 0/9 Up 62039 53 104239232 3 Te 0/10 Up 17740044091 372 7373849244 79 Te 0/11 Up 18182889225 44 7184747584 138 Te 0/12 Up 18182682056 0 3682 1 Te 0/13 Up 18182681434 43 6592378911 144 Te 0/14 Up 61349 55 86281941 15 Te 0/15 Up 59808 58 62060 27 Te 0/16 Up 59889 1 61616 1 Te 0/17 Up
Usage Information Version Description 7.5.1.0 Introduced on the C-Series. pre-Version 6.2.1.0 Introduced on the E-Series. If the packet includes a Layer 2 header, the difference between the link MTU and IP MTU (ip mtu command) must be enough bytes to include the Layer 2 header. When you enter the no mtu command, Dell Networking OS reduces the IP MTU value to 1536 bytes. Link MTU and IP MTU considerations for port channels and VLANs are as follows.
To return a port to accept either tagged or untagged frames (non-hybrid), use the no portmode hybrid command. Defaults non-hybrid Command Modes INTERFACE (conf-if-interface-slot/port) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
802.1QTagged: Hybrid Vlan membership: Vlan 10, Vlan 20 Native VlanId: 10 Dell(conf-if-vl-20)# Example (Vlan) Dell(conf-if-vl-20)#interface vlan 10 Dell(conf-if-vl-10)#no untagged tengigabitethernet 7/1 Dell(conf-if-vl-10)#interface vlan 20 Dell(conf-if-vl-20)#no tagged tengigabitethernet 7/1 Dell(conf-if-vl-20)#interface tengigabitethernet 7/1 Dell(conf-if-gi-7/0)#no portmode hybrid Dell(conf-if-vl-20)# rate-interval Configure the traffic sampling interval on the selected interface.
Related Commands show interfaces — displays information on physical and virtual interfaces. show config Display the interface configuration. S4810 Syntax show config Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.0.2.
Example Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series.
• Command History Usage Information EXEC Privilege Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.2(0.2) Added support for the tunnel interface type. 9.1(0.0) Updated Management Ethernet output to include two global IPv6 addresses on S4810 and Z9000 and added output example showing OpenFlow instance ID. 8.3.12.1 Updated command output to support multiple IPv6 addresses on S4810. 8.3.11.4 Output expanded to support eSR4 optics in Z9000. 8.3.11.
Line Description • Wavelength, Non-qualified — Dell Force10 ID is not present, but wavelength information is available from XFP or SFP serial data • Wavelength, F10 unknown — Dell Force10 ID is present, but not able to determine the optics type • Unknown, Non-qualified — if wavelength is reading error, and F10 ID is not present Dell Networking allows unsupported SFP and XFP transceivers to be used, but Dell Networking OS might not be able to retrieve some data about them.
Line Description – Unicasts = number of MAC unicast packets • Number of VLANs, throttles, discards, and collisions: – Vlans = number of VLAN tagged packets – throttles = packets containing PAUSE frames – discarded = number of packets discarded without any processing – collisions = number of packet collisions – wred=count both packets discarded in the MAC and in the hardware-based queues Rate information... Estimate of the input and output traffic rate over a designated interval (30 to 299 seconds).
Example (1G SFP) Dell#show interfaces tengigabitethernet 2/1 TenGigabitEthernet 2/1 is up, line protocol is down Hardware is Force10Eth, address is 00:01:e8:41:77:95 Current address is 00:01:e8:41:77:95 Pluggable media present, SFP type is 1000BASE-SX Wavelength is 850nm Interface index is 100974648 Port will not be disabled on partial SFM failure Internet address is not set MTU 1554 bytes, IP MTU 1500 bytes LineSpeed 1000 Mbit Flowcontrol rx on tx on ARP type: ARPA, ARP Timeout 04:00:00 Last clearing of "
Pluggable media not present Interface index is 302006472 Internet address is 10.16.130.
Time since last interface status change: 00:05:12 Related Commands show interfaces configured – displays any interface with a non-default configuration. show inventory (S-Series and Z-Series) – displays the S-Series and Z-Series switch types, components (including media), Dell Networking OS version including hardware identification numbers, and configured protocols. show ip interface – displays Layer 3 information about the interfaces.
0 CRC, 0 overrun, 0 discarded Output Statistics: 1 packets, 64 bytes, 0 underruns 1 64-byte pkts, 0 over 64-byte pkts, 0 over 127-byte pkts 0 over 255-byte pkts, 0 over 511-byte pkts, 0 over 1023-byte pkts 0 Multicasts, 1 Broadcasts, 0 Unicasts 0 Vlans, 0 throttles, 0 discarded, 0 collisions Rate info (interval 299 seconds): Input 00.00 Mbits/sec, 0 packets/sec, 0.00% of line-rate Output 00.00 Mbits/sec, 0 packets/sec, 0.
Version Description 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Introduced Example Dell#show interfaces dampening Interface Supp Flaps Penalty Half-Life Reuse Suppress Max-Sup State Te 3/2 Up 0 0 20 800 4500 120 Te 3/10 Up 0 0 5 750 2500 20 Dell# Related Commands dampening — configures dampening on an interface. show interfaces — displays information on a specific physical interface or virtual interface.
Mode Control Indicates if auto negotiation is enabled. If so, indicates the selected speed and duplex. Mode Status Displays auto negotiation fault information. When the interface completes auto negotiation successfully, the autoNegComplete field and the linkstatus field read “True.” AutoNegotiation Advertise Displays the control words the local interface advertises during negotiation. Duplex is either half or full. Asym- and Sym Pause is the types of flow control the local interface supports.
Isolate: False DuplexMode: Full Mode Status: AutoNegComplete: False RemoteFault: False LinkStatus: False JabberDetect: False AutoNegotation Advertise: 100MegFullDplx: True 100MegHalfDplx: True 10MegFullDplx: False 10MegHalfDplx: True Asym Pause: False Sym Pause: False AutoNegotiation Remote Partner's Ability: 100MegFullDplx: False 100MegHalfDplx: False 10MegFullDplx: False 10MegHalfDplx: False Asym Pause: False Sym Pause: False AutoNegotiation Expansion: ParallelDetectionFault: False ...
Hardware is Force10Eth, address is 00:01:e8:4c:f2:82 Current address is 00:01:e8:4c:f2:82 Pluggable media not present Interface index is 34129154 Internet address is not set MTU 1554 bytes, IP MTU 1500 bytes LineSpeed auto, Mode auto ARP type: ARPA, ARP Timeout 04:00:00 Last clearing of "show interface" counters 3w0d17h Queueing strategy: fifo Input Statistics: 0 packets, 0 bytes 5144 64-byte pkts, 0 over 64-byte pkts, 0 over 127-byte pkts 0 over 255-byte pkts, 0 over 511-byte pkts, 0 over 1023-byte pkts 0
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.
Parameters interface stack-unit unit-id Command Modes Command History • EXEC • EXEC Privilege (OPTIONAL) Enter one of the following keywords and slot/port or number information: • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
Example Dell#show interfaces switchport Name: TenGigabitEthernet 13/1 802.1QTagged: Hybrid Vlan membership: Vlan 2, Vlan 20 Native VlanId: 20 Name: TenGigabitEthernet 13/2 802.1QTagged: True Vlan membership: Vlan 2 Name: TenGigabitEthernet 13/3 802.1QTagged: True Vlan membership: Vlan 2 Name: TenGigabitEthernet 13/4 802.1QTagged: True Vlan membership: Vlan 2 --More-- Related Commands interface — configures a physical interface on the switch.
Usage Information Version Description 9.0.2.0 Introduced on theS6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Output augmented with diagnostic data for pluggable media. 7.7.1.0 Removed three fields in the output: Vendor Name, Vendor OUI, and Vendor PN. 7.6.1.0 Introduced on the C-Series and S-Series. 6.5.4.
Interfaces Line Description Bias High Warning threshold Factory-defined setting. Value can differ between SFP and SFP+. TX Power High Warning threshold Factory-defined setting. Value can differ between SFP and SFP+. RX Power High Warning threshold Factory-defined setting. Value can differ between SFP and SFP+. Temp Low Warning threshold Factory-defined setting. Value can differ between SFP and SFP+. Voltage Low Warning threshold Factory-defined setting.
Example Line Description Temperature High Alarm Flag This can be either true or false, depending on the Current voltage value displayed above. Voltage High Alarm Flag This can be either true or false, depending on the Current Temperature value displayed above. Tx Bias High Alarm Flag This can be either true or false, depending on the present Tx bias current value displayed above.
SFP SFP SFP SFP SFP SFP SFP SFP SFP SFP SFP SFP SFP SFP SFP SFP SFP SFP SFP SFP SFP SFP 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Serial Base ID fields Id = 0x03 Ext Id = 0x04 Connector = 0x07 Transciever Code = 0x00 0x00 0x00 0x01 0x20 0x40 0x0c 0x05 Encoding = 0x01 BR Nominal = 0x15 Length(9um) Km = 0x00 Length(9um) 100m = 0x00 Length(50um) 10m = 0x1e Length(62.
SFP 1 Tx Bias Low Alarm Flag = False SFP 1 Tx Power Low Alarm Flag = False SFP 1 Rx Power Low Alarm Flag = True =================================== !-------output truncated ------------------------Related Commands interface — configures a physical interface on the switch. show ip interface — displays Layer 3 information about the interfaces. show interfaces — displays information on a specific physical interface or virtual interface.
show range Display all interfaces configured using the interface range command. S4810 Syntax show range Command Modes INTERFACE RANGE (config-if-range) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.10.0 Introduced on the S4810. ecmp-group — configures a mechanism to monitor traffic distribution.
Disabling a VLAN or a port channel causes different behavior. When a VLAN is disabled, the Layer 3 functions within that VLAN are disabled. Layer 2 traffic continues to flow. Entering the shutdown command on a port channel disables all traffic on the port channel and the individual interfaces within the port channel. To enable a port channel, enter no shutdown on the port channel interface and at least one interface within that port channel.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Supported on LC-EH-GE-50P or the LC-EJ-GE-50P cards. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Usage Information This command is found on the 10/100/1000 Base-T Ethernet interfaces.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.11.1 Introduced on the S55, S60, and S4810 8.1.1.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.1 Introduced on the S4810. Splitting a 40G port into 4x10G port is supported on standalone and stacked units. stack-unit stackunit port number portmode quad dynamically fan-out 40G ports to 10G ports and vice-versa without reload in switch.Split ports cannot be used as stack-link to stack an S4810 system.
Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.
To remove a management application configuration, use the no application {all | application-type} command. Parameters application-type all Enter any of the following keywords: • For DNS, enter the keyword dns. • For FTP, enter the keyword ftp. • For NTP, enter the keyword ntp. • For Radius, enter the keyword radius. • For sFlow collectors, enter the keyword sflow-collector. • For SNMP (traps and MIB responses), enter the keywords snmp . • For SSH, enter the keyword ssh .
all Configure all applications. Defaults None. Command Modes EIS Mode (conf-mgmt-eis) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.3.(0.0) Added support for the HTTP and ICMP traffic on the Z9000, S4810, and S4820T.
management egress-interface-selection To make configured application traffic egress through the management port instead of the front-end (FE) port, enable and configure a management egress interface. S4810 Syntax management egress-interface-selection To disable and remove management egress interface selection (EIS) configurations, use the no management egress-interface-selection command. Defaults None. Command Modes CONFIGURATION Command History This guide is platform-specific.
show management application pkt-cntr Display the number of packets for each application type that have taken the management route. S4810 Syntax show management application pkt-cntr Defaults None. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
sflow-collector snmp ssh syslog tacacs telnet tftp : : : : : : : 0 0 2 0 0 0 0 Port Channel Commands A Link Aggregation Group (LAG) is a group of links that appear to a MAC client as if they were a single link according to IEEE 802.3ad. In Dell Networking OS, a LAG is referred to as a Port Channel. • For the S-Series and Z9000, the maximum port channel ID is 128 and the maximum members per port channel is 16.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-Version 6.2.1.0 Introduced on the E-Series.
shutdown — disables/enables the port channel. group Group two LAGs in a supergroup (“fate-sharing group” or “failover group”). S4810 Syntax group group_number port-channel number port-channel number To remove an existing LAG supergroup, use the no group group_number command. Parameters group_number Enter an integer from 1 to 32 that uniquely identifies this LAG fate-sharing group. port-channel number Enter the keywords port-channel then an existing LAG number.
Parameters channel-number For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
interface loopback — configures a Loopback interface. interface null — configures a null interface. interface vlan — configures a VLAN. shutdown — disables/enables the port channel. minimum-links Configure the minimum number of links in a LAG (Port Channel) that must be in “oper up” status for the LAG to be also in “oper up” status. S4810 Syntax Parameters minimum-links number number Enter the number of links in a LAG that must be in “oper up” status. The range is from 1 to 16. The default is 1.
port-channel failover-group To configure a LAG failover group, access PORT-CHANNEL FAILOVER-GROUP mode. S4810 Syntax port-channel failover-group To remove all LAG failover groups, use the no port-channel failover-group command. Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command. Example Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-Version 6.2.1.0 Introduced on the E-Series.
Version Description 7.5.1.0 Introduced on the C-Series. E-Series legacy command Usage Information Example 720 The following describes the show interfaces port-channel command shown in the following example. Field Description Port-Channel 1... Displays the LAG’s status. In the Example, the status of the LAG’s LAG fatesharing group (“Failover-group”) is listed. Hardware is... Displays the interface’s hardware information and its assigned MAC address. Port-channel is part...
Queueing strategy: fifo 44507301 packets input, 3563070343 bytes Input 44506754 IP Packets, 0 Vlans 0 MPLS 41 64-byte pkts, 44502871 over 64-byte pkts, 249 over 127-byte pkts 407 over 255-byte pkts, 3127 over 511-byte pkts, 606 over 1023-byte pkts Received 0 input symbol errors, 0 runts, 0 giants, 0 throttles 0 CRC, 0 IP Checksum, 0 overrun, 0 discarded 1218120 packets output, 100745130 bytes, 0 underruns Output 5428 Multicasts, 4 Broadcasts, 1212688 Unicasts 1216142 IP Packets, 0 Vlans, 0 MPLS 0 throttles,
show port-channel-flow Display an egress port in a given port-channel flow. S4810 Syntax show port-channel-flow outgoing-port-channel number incoming-interface interface {source-ip address destination-ip address} | {source-port number destination-port number} | {source-mac address destination-mac address {vlan vlanid | ether-type}} Parameters outgoing-portchannel number Enter the keywords outgoing-port-channel then the number of the port channel to display flow information.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.10.0 Introduced on the S4810. Because this command calculates based on a Layer 2 hash algorithm, use this command to display flows for switched Layer 2 packets, not for routed packets (use the show ip flow command to display routed packets). The show port-channel-flow command returns the egress port identification in a given port-channel if a valid flow is entered.
S4810 Syntax tdr-cable-test interface Parameters interface Enter the keyword TenGigabitEthernet then the slot/port information for the 100/1000 Ethernet interface. Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7.0.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7.0.0 Introduced on the S5000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the E-Series ExaScale. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 6.1.1.0 Introduced.
• Routing information protocol (RIP) is not supported with the UDP Broadcast feature. • If you configure this feature on an interface using the ip udp-helper udp-port command, the ip directedbroadcast command becomes ineffective on that interface. • The existing show interface command has been modified to display the configured broadcast address. debug ip udp-helper Enable UDP debug and display the debug information on a console.
Parameters address Enter an IP broadcast address in dotted decimal format (A.B.C.D). Defaults Not configured. Command Modes INTERFACE (config-if) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. Pre-version 8.3.7.0 Introduced on the E-Series ExaScale. If you configure the ip helper-address command and ip udp-helper udp-port command, the behavior is that the UDP broadcast traffic with port numbers 67/68 is unicast relayed to the DHCP server per the ip helper-address configuration. This occurs regardless if the ip udp-helper udp-port command contains port numbers 67/68 or not.
ip udp-helper udp-port — enables the UDP broadcast feature on an interface either for all UDP ports or a specified list of UDP ports. ip http source-interface Specify an interface as the source interface for HTTP connections. This feature is supported on S4810 platform. Syntax ip http source-interface interface To delete an interface, use theno ip http source-interface interface command.
25 Enhanced Validation of Interface Ranges This functionality is supported on the S4810 platform. You can avoid specifying spaces between the range of interfaces, separated by commas, that you configure by using the interface range command. For example, if you enter a list of interface ranges, such as interface range fo 2/0-1,te 10/0,gi 3/0,fa 0/0, this configuration is considered valid. The comma-separated list is not required to be separated by spaces in between the ranges.
26 Internet Protocol Security (IPSec) Internet protocol security (IPSec) is an end-to-end security scheme for securing IP communications by authenticating and encrypting all packets in a session. Use IPSec between hosts, gateways, or hosts and gateways. IPSec uses a series of protocol functions to achieve information security: • Authentication Headers (AH) — Connectionless integrity and origin authentication for IP packets.
esp-authentication esp-encryption • md5 — Use Message Digest 5 (MD5) authentication. • sha1 — Use Secure Hash Algorithm 1 (SHA-1) authentication. • null — Causes an encryption policy configured for the area to not be inherited on the interface. Enter the keywords esp-authentication then the transform type of operation to apply to traffic. The transform type represents the encryption or authentication applied to traffic. • md5 — Use Message Digest 5 (MD5) authentication.
crypto ipsec policy Create a crypto policy used by ipsec. S4810 Syntax crypto ipsec policy name seq-num ipsec-manual To delete a crypto policy entry, use the no crypto ipsec policy name seq-num ipsec-manual command. Parameters name Enter the name for the crypto policy set. seq-num Enter the sequence number assigned to the crypto policy entry. Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.2(0.2) Introduced on the Z9000, S4810, and S4820T. match Apply an match filter to the crypto policy.
match match match match 4 5 6 7 tcp tcp tcp tcp 1.1.1.1 1.1.1.1 1.1.1.1 1.1.1.1 /32 /32 /32 /32 0 1.1.1.2 /32 23 23 1.1.1.2 /32 0 0 1.1.1.2 /32 21 21 1.1.1.2 /32 0 session-key Specify the session keys used in the crypto policy entry. S4810 Syntax session-key {inbound | outbound} {ah spi hex-key-string | esp spi encrypt hex-key-string auth hex-key-string To delete the session key information from the crypto policy, use the no session-key {inbound | outbound} {ah | esp} command.
show crypto ipsec transform-set Display the transform set configuration. S4810 Syntax show crypto ipsec transform-set name Parameters name Enter the name of the transform set. Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.2(0.
Inbound AH SPI : Inbound ESP Auth SPI : Inbound ESP Encry SPI : Inbound AH Key : Inbound ESP Auth Key : Inbound ESP Encry Key : Outbound AH SPI : Outbound ESP Auth SPI : Outbound ESP Encry SPI: Outound AH Key : Outound ESP Auth Key : Outound ESP Encry Key : Match sequence Num Protocol type IP or IPv6 Source address Source mask Source port Destination address Destination mask Destination port source-interface name source-interface num 0 0 0 [0]:: [0]:: [0]:: 0 0 0 [0]:: [0]:: [0]:: : : : : : : : : : : : 2
27 IPv4 Routing The basic IPv4 commands are supported by Dell Networking operating system on the S4810 platform. arp To associate an IP address with a MAC address in the switch, use address resolution protocol (ARP). S4810 Syntax arp [vrf vrf-name] ip-address mac-address interface To remove an ARP address, use the no arp ip-address command. Parameters vrf vrf-name Enter a VRF name to configure an ARP entry for that VRF.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.0 Introduced on the E-Series. You cannot use Class D or Class E IP addresses or zero IP address (0.0.0.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Introduced on the S4810. Usage Information This timer is an exponential backoff timer. Over the specified period, the time between ARP requests increases. This behavior reduces the potential for the system to slow down while waiting for a multitude of ARP responses. Related Commands show arp retries — displays the configured number of ARP retries.
arp max-entries Enables you to configure the maximum number of ARP entries per VRF that are allowed for IPv4.. S4810 Syntax Parameters arp max-entries [vrf vrf-name] max-number vrf vrf-name Enter the name of a specific VRF for which you want to configure maximum number of ARP entries that IPv4 allows. max-number Enter the maximum number of ARP entries that a VRF RTM can hold. The range is from 0 to 65535. Defaults Not configured.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced. Usage Information Retries are 20 seconds apart. Related Commands show arp retries — displays the configured number of ARP retries. arp timeout Set the time interval for an ARP entry to remain in the ARP cache. S4810 Syntax arp timeout minutes Parameters minutes Enter the number of minutes.
clear arp-cache Clear the dynamic ARP entries from a specific interface or optionally delete (no-refresh) ARP entries from the content addressable memory (CAM). S4810 Syntax Parameters clear arp-cache [vrf vrf-name | interface | ip ip-address] [no-refresh] vrf vrf-name (OPTIONAL) Enter the keyword vrf and then the name of the VRF to clear the ARP cache corresponding to that VRF.
Version Description 8.2.1.0 Added support for 4094 VLANs on the E-Series ExaScale (the prior limit was 2094). 8.1.1.0 Introduced on the E-Series ExaScale. 7.9.1.0 Introduced VRF on the E-Series. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. clear host Remove one or all dynamically learned host table entries. S4810 Syntax clear host name Parameters name Enter the name of the host to delete.
Parameters unit-number Enter the number of the stack unit. vrf vrf-name Enter the keyword vrf followed by the name of the VRF to clear all FIB entries corresponding to that VRF. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.9.1.0 Introduced VRF on the E-Series. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Added support for 4094 VLANs on the E-Series ExaScale (the prior limit was 2094). 8.1.1.0 Introduced on the E-Series ExaScale. 7.
Version Description 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.4.10 Introduced on the E-Series. Example Dell#debug ip dhcp 00:12:21 : %RELAY-I-PACKET: BOOTP REQUEST (Unicast) received at interface 113.3.3.17 BOOTP Request, hops = 0, XID = 0xbf05140f, secs = 0, hwaddr = 00:60:CF:20:7B:8C, giaddr = 0.0.0.0 00:12:21 : %RELAY-I-BOOTREQUEST: Forwarded BOOTREQUEST for 00:60:CF:20:7B: 8C to 14.
To disable the debug logs for dhcpv6 relay agent transactions, use the debug ipv6 dhcp command. Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command-Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S4810, S4820T, S6000 and Z-Series.
Example Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Added support for 4094 VLANs on the E-Series ExaScale (the prior limit was 2094). 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.3.1.0 Added the count option.
• For the Management interface on the stack-unit, enter the keyword ManagementEthernet then the slot/port information. The slot range is from 0 to 1. The port range is 0. • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Command Modes EXEC Privilege Command History This guide is platform-specific.
Field Description ICMP type= Displays the ICMP type and code. IP Fragment States that it is a fragment and displays the unique number identifying the fragment (Ident) and the offset (in 8-byte units) of this fragment (fragment offset) from the beginning of the original datagram. Example IP: s=10.1.2.62 (local), d=10.1.2.206 (Ma 0/0), len 54, sending TCP src=23, dst=40869, seq=2112994894, ack=606901739, win=8191 ACK PUSH IP: s=10.1.2.206 (Ma 0/0), d=10.1.2.
ip address Assign a primary and secondary IP address to the interface. S4810 Syntax ip address ip-address mask [secondary] To delete an IP address from an interface, use the no ip address [ip-address] command. Parameters ip-address Enter an IP address in dotted decimal format. mask Enter the mask of the IP address in slash prefix format (for example, /24). secondary (OPTIONAL) Enter the keyword secondary to designate the IP address as the secondary address. Defaults Not configured.
Defaults Disabled (that is, the interface does not receive directed broadcast packets) Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. To configure a list of possible domain names, configure the ip domain-list command up to six times. If you configure both the ip domain-name and ip domain-list commands, the software tries to resolve the name using the ip domain-name command.
Usage Information Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. To fully enable DNS, also specify one or more domain name servers with the ip name-server command. Dell Networking OS does not support sending DNS queries over a VLAN. DNS queries are sent out all other interfaces, including the Management port. To view current bindings, use the show hosts command. Related Commands ip name-server — specifies a DNS server.
Usage Information Version Description 7.5.1.0 Introduced on the C-Series. You can only configure one domain name with the ip domain-name command. To configure more than one domain name, configure the ip domain-list command up to six times. To enable dynamic resolution of hosts, use the following steps: • specify a domain name server with the ip name-server command • enable DNS with the ip domain-lookup command To view current bindings, use the show hosts command.
Usage Information Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. You can add multiple DHCP servers by entering the ip helper-address command multiple times. If multiple servers are defined, an incoming request is sent simultaneously to all configured servers and the reply is forwarded to the DHCP client.
Version Description 6.3.1.0 Introduced for the E-Series. Usage Information This command disables the incrementing of the hops field when boot requests are relayed to a DHCP server through Dell Networking OS. If the incoming boot request already has a non-zero hops field, the message is relayed with the same value for hops. However, the message is discarded if the hops field exceeds 16, to comply with the relay agent behavior specified in RFC 1542.
ip icmp source-interface Enable the ICMP error and unreachable messages to be sent with the source interface IP address, such as the loopback address, instead of the hops of the preceding devices along the network path to be used for easy debugging and diagnosis of network disconnections and reachability problems with IPv4 packets.
Example Dell(conf)#ip icmp source-interface tengigabitethernet 1/1 Dell(conf)# ipv6 icmp source-interface Enable the ICMP error and unreachable messages to be sent with the source interface IP address, such as the loopback address, instead of the hops of the preceding devices along the network path to be used for easy debugging and diagnosis of network disconnections and reachability problems with IPv6 packets.
the IP address of the adjacent, neighboring interface from which the packet is received, it is difficult to employ the ping and traceroute utilites.
ip max-routes Enables you to configure the maximum number of protocol routes per VRF that are allowed for IPv4. S4810 Syntax ip max-routes [vrf vrf-name] max-number Parameters vrf vrf-name Enter the keyword vrf and then the name of the VRF for which you want to configure maximum number of protocol routes that IPv4 allows. max-number Enter the maximum number of protocol routes that a VRF RTM can hold. The range is from 0 to 7500. Defaults Not configured.
The following is a list of the Dell Networking OS version history for this command. Usage Information Verison Description 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 6.1.1.0 Introduced on the E-Series. When you enter the no mtu command, Dell Networking OS reduces the ip mtu value to 1536 bytes. To return the IP MTU value to the default, use the no ip mtu command. Starting with Dell Networking OS Release 9.2(0.
Related Commands Layer 2 Overhead Difference between Link MTU and IP MTU Tagged Packet with VLAN-Stack Header 26 bytes mtu — sets the link MTU for an Ethernet interface. ip name-server Enter up to six IPv4 addresses of name servers. The order you enter the addresses determines the order of their use. S4810 Syntax ip name-server ipv4-address [ipv4-address2...ipv4-address6] To remove a name server, use the no ip name-server ip-address command.
You can separately configure both IPv4 and IPv6 domain name servers. ip proxy-arp Enable proxy ARP on an interface. S4810 Syntax ip proxy-arp To disable proxy ARP, use the no ip proxy-arp command. Defaults Enabled. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
To delete all routes matching a certain route, use the no ip route destination mask command. Parameters vrf vrf-name (Optoinal) Enter the keyword vrf and then the name of the VRF to configure a static route corresponding to that VRF. Use this VRF option after the ip route keyword to configure a static route on that particular VRF. destination Enter the IP address in dotted decimal format of the destination device. mask Enter the mask in the slash prefix format (/x) of the destination IP address.
Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Included the weighted parameter to support weighted ECMP feature. 9.4.(0.0) Added support for VRF. 9.0.2.
You cannot use the VRF attribute of this command to configure routes in a management VRF. When a specific VRF is deleted, all the configured static routes corresponding to that VRF are automatically removed. Example Dell(conf)#ip route 1.1.1.0/24 4.4.4.2 weight 100 Dell(conf)#ip route 1.1.1.0/24 6.6.6.2 weight 200 Dell(conf)#do show running-config | grep route ip route 1.1.1.0/24 4.4.4.2 weight 100 ip route 1.1.1.0/24 6.6.6.2 weight 200 Dell(conf)#ip route vrf test 1.1.1.0/24 4.4.4.
ip unreachables Enable the generation of internet control message protocol (ICMP) unreachable messages. S4810 Syntax ip unreachables To disable the generation of ICMP messages, use the no ip unreachables command. Defaults Disabled. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
mac {dest-mac | source-dest-mac | source-mac} tcp-udp enable • dest-ip — Uses destination IP address and destination port fields to hash. The hashing mechanism returns a 3-bit index indicating which port the packet should be forwarded. • source-ip — Uses source IP address and source port fields to hash. The hashing mechanism returns a 3-bit index indicating which port the packet should be forwarded.
• IP destination address • TCP/UDP source port • TCP/UDP destination port load-balance hg Choose the traffic flow parameters the hash calculation uses while distributing the traffic across internal higig links.
gre-ipv4 | mac-inmac]} • mac-in-mac — Use mac-in-mac field in hash calculation. Defaults IP selection 5-tuples (source-ip dest-ip vlan protocol L4-source-port L4-dest-port). Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
fortyGigE Enter the keyword fortyGigE to specify a forty Gigbit Ethernet interface. vlan Enter the keyword vlan to specify a vlan interface. tengigabitethernet Enter the keyword tengigabitethernet to specify a ten Gigabit Ethernete interface. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
NOTE: Use this attribute to start a BGP instance for either a specific address family corresponding to the default VRF or an IPv4 address family corresponding to a non-default VRF. interface interface (OPTIONAL) Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
Usage Information Version Description 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Added support for 4094 VLANs on the E-Series ExaScale (the prior limit was 2094). 8.1.1.0 Introduced on the E-Series ExaScale. 7.9.1.0 Introduced VRF on the E-Series. 7.8.1.0 Augmented to display local ARP entries learned from private VLANs (PVLANs). 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.
Example (Private VLAN) NOTE: In this example, Line 1 shows community VLAN 200 (in primary VLAN 10) in a PVLAN. Line 2 shows primary VLAN 10. Dell#show arp Protocol Address Age(min) Hardware Address Interface VLAN CPU --------------------------------------------------------------Internet 5.5.5.1 - 00:01:e8:43:96:5e Vl 10 pv 200 Internet 5.5.5.10 - 00:01:e8:44:99:55 Vl 10 Internet 10.1.2.4 1 00:01:e8:d5:9e:e2 Ma 0/0 Internet 10.10.10.4 1 00:01:e8:d5:9e:e2 Ma 0/0 Internet 10.16.127.
Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.1.0 Introduced. arp retries — sets the number of ARP retries in case the system does not receive an ARP reply in response to an ARP request. show hosts View the host table and DNS configuration. S4810 Syntax Command Modes Command History show hosts • EXEC • EXEC Privilege This guide is platform-specific.
Field Description Name/address lookup... States if DNS is enabled on the system. • If DNS is enabled, the Name/Address lookup is domain service. • If DNS is not enabled, the Name/Address lookup is static mapping Name servers are... Lists the name servers, if configured. Host Displays the host name assigned to the IP address.
Parameters Command Modes Command History number Enter the number of the line card. pipe-number Enter the number of the line card’s port-pipe. The range is from 0 to 1. ip-address mask [longer-prefix] (OPTIONAL) Enter the IP address and mask of a route to CAM entries for that route only. Enter the keyword longer-prefixes to view routes with a common prefix. index index-number (OPTIONAL) Enter the keyword index then the CAM index number. The range depends on CAM size.
Field Description Mac Addr Displays the next-hop router’s MAC address. Port Displays the egress interface. Use the second half of the entry to determine the interface. For example, in the entry 17cl CP, the CP is the pertinent portion.
18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Dell# 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1312 1312 3932 1312 1312 1312 1312 1312 1312 1312 1312 1312 1312 1312 1312 1312 1312 1312 8 show ip cam stack-unit Display CAM entries for a port-pipe of a stack-unit on a S-Series or Z-Series switch.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Added support for VRF. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.
0.0.0.0/0 Dell# Example (MemberInfo) 0 1 0 00:00:00:00:00:00 CP - Dell#show ip cam stack-unit 3 po 0 ecmp-group member-info detail Group Index Member Count Mac-Addr Port VLan ID -------------------------------------------------------------------------------0 2 00:03:00:00:00:02 Po 10 20 00:01:00:00:00:02 Te 3/42 1000 Dell# show ip fib linecard View all forwarding information base (FIB) entries.
Example Field Description Destination Lists the destination IP address. Gateway Displays either the word “direct” and an interface for a directly connected route or the remote IP address used to forward the traffic. First-Hop Displays the first hop IP address. Mac-Addr Displays the MAC address. Port Displays the egress-port information. VId Displays the VLAN ID. If no VLAN is assigned, zero (0) is listed. Index Displays the internal interface number. EC Displays the number of ECMP paths.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
S S Example (Show command output with Weighted ECMP Enabled) 20.1.1.0/24 100.1.1.0/24 via 3.1.1.2, Vl 30 via 10.1.1.0, weight 7 via 20.1.1.0, weight 1 Dell#show ip fib stack-unit 1 Destination Gateway First-Hop Mac-Addr Port -----------------------------------------------------------------------------------0.0.0.0/0 0.0.0.0 00:00:00:00:00:00 CP 1.1.1.0/24 Direct, Lo 0 0.0.0.0 00:00:00:00:00:00 CP 1.1.1.1/32 via 127.0.0.1 127.0.0.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.10.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.1.1.0 Introduced on the E-Series ExaScale. 7.9.1.0 Introduced VRF on the E-Series. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series.
Command Modes Command History • For the Management interface on the stack-unit, enter the keyword ManagementEthernet then the slot/port information. The slot range is from 0 to 1. The port range is 0. • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a Null interface, enter the keyword null then the Null interface number. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094.
Example Lines Description Inbound access... Displays the name of the configured incoming access list. If none is configured, the phrase “not set” is displayed. Proxy ARP... States whether proxy ARP is enabled on the interface. Split horizon... States whether split horizon for RIP is enabled on the interface. Poison Reverse... States whether poison for RIP is enabled on the interface. ICMP redirects... States if ICMP redirects are sent. ICMP unreachables...
show ip management-route View the IP addresses assigned to the Management interface. S4810 Syntax show ip management-route [all | connected | summary | static] Parameters Command Modes Command History all (OPTIONAL) Enter the keyword all to view all IP addresses assigned to all Management interfaces on the switch. connected (OPTIONAL) Enter the keyword connected to view only routes directly connected to the Management interface.
show ipv6 management-route Display the IPv6 static routes configured for the management interface. S4810 Syntax Parameters show ipv6 management-route [all | connected | summary | static] all (OPTIONAL) Enter the keyword all to view all IP addresses assigned to all Management interfaces on the switch. connected (OPTIONAL) Enter the keyword connected to view only routes directly connected to the Management interface.
• Command History EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.
Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf and then the VRF name to list the routes in the route table of a specific VRF. ip-address (OPTIONAL) Specify a name of a device or the IP address of the device to view more detailed information about the route. mask (OPTIONAL) Specify the network mask of the route. Use this parameter with the IP address parameter. longer-prefixes (OPTIONAL) Enter the keywords longer-prefixes to view all routes with a common prefix.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.9.1.0 Introduced VRF on the E-Series. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. The following describes the show ip route all command in the following example.
If weighted ECMP is disabled, the show ip route command does not show the weighted ECMP route information.
L2 - IS-IS level-2, IA - IS-IS inter area, * - candidate default, > - non-active route, + - summary route Gateway of last resort is not set Destination Gateway Dist/ Metric Last Change --------------------------- ----------S 1.1.1.0/24 4.4.4.2, via Te 1/4 , weight 100 1/0 00:00:01 6.6.6.2, via Te 1/16, weight 200 C 4.4.4.0/24 Direct, Te 1/4 0/0 00:01:32 C 6.6.6.0/24 Direct, Te 1/16 0/0 00:01:25 Dell# show ip route 1.1.1.0/24 Routing entry for 1.1.1.
show ip route list Display IP routes in an IP prefix list. S4810 Syntax Parameters Command Modes Command History show ip route vrf vrf-name list prefix-list prefix-list Enter the name of a configured prefix list. vrf vrf-name Enter the keyword vrf followed by the name of the VRF to display IP routes in an IP prefix list corresponding to that VRF. • EXEC • EXEC Privilege This guide is platform-specific.
R C Related Commands 2.1.3.0/24 2.1.4.0/24 via 2.1.4.1, Te 4/43 Direct, Te 4/43 120/1 0/0 3d1h 3d1h ip prefix-list — enters CONFIGURATION-IP PREFIX-LIST mode and configures a prefix list. show ip prefix-list summary — displays a summary of the configured prefix lists. show ip route summary View a table summarizing the IP routes in the switch.
Column Heading Description Example Non-active Routes Identifies the back-up routes when a route is learned by two different protocols. If the best route or active route goes down, the non-active route becomes the best route. ospf 100 If routing protocols (OSPF, RIP) are configured and routes are advertised, then information on those routes is displayed. Total 1388 active... Displays the number of active and non-active routes and the memory usage of those routes.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.5.1.0 F10 Monitoring MIB available for the ip traffic statistics command.
Keyword Definition ...socket full The applications buffer is full and the incoming packet are dropped. The Dell Monitoring MIB provides access to the following statistics. Example • IP Statistics: Bcast: Received: Object = f10BcastPktRecv, OIDs = 1.3.6.1.4.1.6027.3.3.5.1.1 • IP Statistics: Bcast: Sent: Object = f10BcastPktSent, OIDs = 1.3.6.1.4.1.6027.3.3.5.1.2 • IP Statistics: Mcast: Received: Object = f10McastPktRecv, OIDs = 1.3.6.1.4.1.6027.3.3.5.1.
Parameters all Enter the keyword all to view all TCP information. cp Enter the keyword cp to view only TCP information from the Control Processor. rp1 Enter the keyword rp1 to view only TCP statistics from Route Processor 1. rp2 Enter the keyword rp2 to view only TCP statistics from Route Processor 2. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Example Field Description 10184 ack... Displays the number of acknowledgement packets and bytes received. Sent: Displays the total number of TCP packets sent and the number of urgent packets sent. 25 control packets... Displays the number of control packets sent and the number retransmitted. 11603 data packets... Displays the number of data packets sent. 24 data packets retransmitted Displays the number of data packets resent. 355 ack..
28 IPv6 Access Control Lists (IPv6 ACLs) IPv6 ACLs and IPv6 Route Map commands are supported on Dell Networking S4810 platform. NOTE: For IPv4 ACL commands, refer to the Access Control Lists (ACL) chapter. Important Points to Remember • Certain platforms require manual CAM usage space allotment. For more information, refer to the cam-acl command. • Egress IPv6 ACL and IPv6 ACL on the Loopback interface is not supported. • Reference to an empty ACL permits any traffic.
Example Version Description 8.3.7.0 Introduced on the S4810. 8.4.2.1 Introduced on the S-Series. 8.4.2.0 Introduced on the E-Series TeraScale. 7.8.1.0 Introduced on the C-Series. Dell#show cam-acl-egress -- Chassis Egress Cam ACL -Current Settings(in block sizes) L2Acl : 1 Ipv4Acl : 1 Ipv6Acl : 2 -- Stack unit 0 -Current Settings(in block sizes) L2Acl : 1 Ipv4Acl : 1 Ipv6Acl : 2 Dell#show cam-acl Related Commands cam-acl — configures CAM profiles to support IPv6 ACLs.
Example Version Description 7.8.1.0 Introduced on the C-Series.
L2Qos : 3 Dell#show cam-acl Related Commands cam-acl — configures CAM profiles to support IPv6 ACLs. permit icmp To allow all or specific internet control message protocol (ICMP) messages, configure a filter.
permit To configure a filter that matches the filter criteria, select an IPv6 protocol number, ICMP, IPv6, TCP, or UDP. Syntax permit {ipv6-protocol-number | icmp | ipv6 | tcp | udp} To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command syntax if you know the filter’s sequence number • Use the no permit {ipv6-protocol-number | icmp | ipv6 | tcp | udp} command ip-protocol-number Enter an IPv6 protocol number. The range is from 0 to 255.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.10.0 Introduced on the S4810. ipv6 access-list Configure an access list based on IPv6 addresses or protocols. S4810 Syntax ipv6 access-list access-list-name cpu-qos {permit | deny} ospfv3 To delete an access list, use the no ipv6 access-list access-list-name command.
Usage Information Version Description 8.4.2.1 Introduced on the S-Series. 8.2.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the C-Series. Increased the name string to accept up to 140 characters. Prior to version 7.8.1.0, names are up to 16 characters long. 7.4.1.0 Introduced on the E-Series TeraScale. The number of entries allowed per ACL is hardware-dependent. For detailed specification on entries allowed per ACL, refer to your line card documentation.
Usage Information For the new settings to take effect, save the new CAM settings to the startup-config (write-mem or copy run start), then reload the system. The total amount of space allowed is 4 FP Blocks.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.4.2.0 Introduced on the E-Series TeraScale. 8.2.1.0 Introduced on the S-Series. 7.8.1.0 Introduced on the C-Series. For the new settings to take effect, save the new CAM settings to the startup-config (write-mem or copy run start), then reload the system. The total amount of space allowed is 16 FP blocks.
29 IPv6 Basics IPv6 basic commands are supported on the Dell Networking OS. NOTE: For information about the Dell Networking operating software version and platform that supports IPv6 in each software feature, refer to the IPv6 Addressing chapter of the Dell Networking OS Configuration Guide. clear ipv6 fib Clear (refresh) all forwarding information base (FIB) entries on a linecard or stack unit.
clear ipv6 route Clear (refresh) all or a specific route from the IPv6 routing table. S4810 Syntax clear ipv6 route [vrf vrf-name] {* | ipv6-address prefix-length} Parameters vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to clear the IPv6 routes corresponding to that VRF. * Enter the * to clear (refresh) all routes from the IPv6 routing table. ipv6-address prefixlength Enter the IPv6 address in the x:x:x:x::x format then the prefix length in the /x format.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. maximum dynamic-routes-ipv6 Specify the maximum number of dynamic (protocol) IPv6 routes a VRF can have. S4810 Syntax maximum dynamic-routes—ipv6 limit {warn-threshold threshold-value | warningonly} To remove the limit on the maximum number of IPv6 routes used, use the no maximum dynamicroutes-ipv6 command. Parameters limit Maximum number of IPv6 routes allowed in a VRF.
ipv6 address autoconfig Configure IPv6 address auto-configuration for the management interface. S4810 Syntax ipv6 address autoconfig To disable the address autoconfig operation on the management interface, use the no ipv6 address autoconfig command. Default Disabled Command Modes INTERFACE (management interface only) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
To remove the IPv6 address, use the no ipv6 address {ipv6-address prefix-length} command. Parameters ipv6-address prefixlength Enter the IPv6 address in the x:x:x:x::x format then the prefix length in the /x format. The range is from /0 to /128. NOTE: The :: notation specifies successive hexadecimal fields of zeros. Defaults none Command Modes INTERFACE Command History This guide is platform-specific.
ipv6 address eui64 Configure IPv6 EUI64 address configuration on the interface. S4810 Syntax ipv6 address {ipv6-address prefix-length} eui64 To disable IPv6 EUI64 address autoconfiguration, use the no ipv6 address {ipv6-address prefix-length} eui64 command. Parameters ipv6-address prefixlength Enter the IPv6 prefix in the x:x:x:x::x format then the prefix length in the /x format. The range is from /0 to /128. NOTE: The :: notation specifies successive hexadecimal fields of zeros.
Parameters pps Enter the maximum number of error packets generated per second. The range is from 1 to 200, where 0 disables the rate-limiting. Default 100 pps Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 8.3.19.0 Introduced on the S4820T. 8.3.
ipv6 host Assign a name and IPv6 address the host-to-IPv6 address mapping table uses. S4810 Syntax ipv6 host name ipv6-address To remove an IP host, use the no ipv6 host name {ipv6–address}. Parameters name Enter a text string to associate with one IP address. ipv6-address Enter the IPv6 address (X:X:X:X::X) to be mapped to the name. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.4.2.1 Introduced on the C-Series and S-Series. 8.4.1.0 Introduced on the E-Series TeraScale.
ipv6 nd dns-server Configures Recursive DNS Server (RDNSS) addresses to be distributed via IPv6 router advertisements to an IPv6 device. Syntax ipv6 nd dns-server {ipv6-RDNSS-address} {lifetime | infinite} To remove the IPv6 RDSS configuration, use no ipv6 nd dns-server {ipv6-RDNSS-address} {lifetime | infinite} Parameters ipv6-RDNSSaddress Enter the IPv6 Recursive DNS Server’s (RDNSS) address. You can specify up to 4 IPv6 RDNSS server addresses. lifetime Enter the lifetime in seconds.
no-advertise Enter the keyword no-advertise to prevent the specified prefix from being advertised. no-autoconfig Enter the keywords no-autoconfig to disable Stateless Address Autoconfiguration. no-rtr-address Enter the keyword no-rtr-address to exclude the full router address from router advertisements (the R bit is not set). off-link Enter the keywords off-link to advertise the prefix without stating to recipients that the prefix is either on-link or off-link.
To remove the IPv6 route, use the no ipv6 route [vrf vrf-name]ipv6-address prefixlength {ipv6-address | interface | interface ipv6-address} [distance] [tag value] [permanent] [weight] command. Parameters vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to install IPv6 routes in that VRF. ipv6-address prefixlength Enter the IPv6 address in the x:x:x:x::x format then the prefix length in the /x format. The range is from /0 to /128.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added support for VRF. Also included the weight parameter to support weighted ECMP feature. Introduced on the S6000-ON. 9.0.0.0 Introduced on the Z9000. 8.3.19.
ipv6 unicast-routing Enable IPv6 Unicast routing. S4810 Syntax ipv6 unicast-routing To disable unicast routing, use the no ipv6 unicast-routing command. Defaults Enabled Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.0.0.
show ipv6 cam stack-unit Displays the IPv6 CAM entries for the specified stack-unit. S4810 Syntax Parameters show ipv6 cam [vrf vrf-name] stack-unit unit-number port-set {0-1} [summary | index | ipv6 address] vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to display IPv6 CAM entries corresponding to that VRF. NOTE: If you do not specify this option, IPv6 CAM entries corresponding to the default VRF are displayed. unit-number Enter the stack unit’s ID number.
NOTE: If a route has a mask greater than 64, no output is displayed and no output is displayed for show ipv6 cam stack-unit unit-number port-set {0-1} ipv6-address, but an equivalent /64 entry would be listed in the show ipv6 cam stack-unit unit-number port-set {0-1} output.
summary (OPTIONAL) Enter the keyword summary to view a summary of entries in IPv6 cam. ipv6-address Enter the IPv6 address in the x:x:x:x::x/n format to display networks that have more specific prefixes. The range is from /0 to /128. NOTE: The :: notation specifies successive hexadecimal fields of zeros. Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific.
Related Commands Version Description 8.3.7.0 Introduced on the S4810. ipv6 nd dad attempts — Configure system to set the flow label field in the packets to zero. show ipv6 interface Display the status of interfaces configured for IPv6.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.2.(0.0) Added support for tunnel interface. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.5.1.
Actual address is 300::1, subnet is 300::/64 (MANUAL) Remaining lifetime: infinite Virtual-IP IPv6 address is not set Global Anycast address(es): Joined Group address(es): ff02::1 ff02::1:ff00:1 ff02::1:ffa7:497e ND MTU is 0 ICMP redirects are not sent DAD is enabled, number of DAD attempts: 3 ND reachable time is 20410 milliseconds ND base reachable time is 30000 milliseconds ND retransmit interval is 1000 milliseconds ND hop limit is 64 Dell# Example (Brief) Example (tunnel) 834 IPv6 Basics Dell#show
show ipv6 mld_host Display the IPv6 MLD host counters. S4810 Syntax show ipv6 mld_host Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
show ipv6 route Displays the IPv6 routes. S4810 Syntax show ipv6 route [ipv6-address prefix-length] [vrf vrf-name] [hostname] [all] [bgp as number] [connected] [isis tag] [list prefix-list name] [ospf process-id] [rip] [static] [summary] Parameters ipv6-address prefixlength (OPTIONAL) Enter the IPv6 address in the x:x:x:x::x format then the prefix length in the /x format. The range is from /0 to /128. NOTE: The :: notation specifies successive hexadecimal fields of zeros.
Usage Information Example (S-Series) Version Description 8.2.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series TeraScale. The following describes the show ipv6 route command shown in the following examples.
C C S L Dell# ----------------------------------------------------100::/64 [0/0] Direct, Te 1/12/1, 20:00:18 400::/64 [0/0] Direct, Tu 1, 00:09:02 800::/64 [1/0] via 100::1, Te 1/12/1, 00:00:50 fe80::/10 [0/0] Direct, Nu 0, 20:00:18 Dell#show ipv6 route Codes: C - connected, L - local, S - static, R - RIP, B - BGP, IN - internal BGP, EX - external BGP,LO - Locally Originated, O - OSPF, IA - OSPF inter area, N1 - OSPF NSSA external type 1, N2 - OSPF NSSA external type 2, E1 - OSPF external type 1, E2 - OSP
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.4.2.1 Introduced on the C-Series and S-Series. 8.2.1.0 Introduced on the E-Series ExaScale. 7.4.1.0 Introduced on the E-Series TeraScale.
30 iSCSI Optimization Internet small computer system interface (iSCSI) optimization enables quality-of-service (QoS) treatment for iSCSI storage traffic on an S4810 system. To configure and verify the iSCSI optimization feature, use the following Dell Networking OS commands. advertise dcbx-app-tlv Configure DCBX to send iSCSI TLV advertisements. S4810 Syntax advertise dcbx-app-tlv iscsi To disable DCBX iSCSI TLV advertisements, use the no advertise dcbx-app-tlv iscsi command. Defaults Disabled.
To remove the iSCSI session aging time, use the no iscsi aging time command. Parameters time Enter the aging time for the iSCSI session. The range is from 5 to 43,200 minutes. Defaults 10 minutes Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 8.3.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.0 Introduced on MXL 10/40GbE Switch IO Module. By default, iSCSI flows are assigned to dot1p priority 4.
iscsi priority-bits Configure the priority bitmap that advertises in the iSCSI application TLVs. S4810 Syntax iscsi priority-bits To remove the configured priority bitmap, use the no iscsi priority-bits command. Defaults 4 (0x10 in the bitmap) Command Modes PROTOCOL LLDP (only on the global, not on the interface) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
iscsi target port Configure the iSCSI target ports and optionally, the IP addresses on which iSCSI communication is monitored. S4810 Syntax iscsi target port [tcp-port-2...tcp-port-16]ip-address [ip-address] To remove the configured iSCSI target ports or IP addresses, use the no iscsi target port command. Parameters tcpport-2...tcpport- 16 Enter the tcp-port number of the iSCSI target ports.
The following is a list of the Dell Networking OS version history for this command. Example Related Commands Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.0 Introduced on MXL 10/40GbE Switch IO Module.
Session 1: --------------------------------------------------------Target: iqn.2001-05.com.equallogic:0-8a0906-0f60c2002-0360018428d48c94iom011 Initiator: iqn.1991-05.com.microsoft:win-x9l8v27yajg ISID: 400001370000. Usage Information Only sessions the switch observes are learned; sessions flowing through an adjacent switch are not learned. After the switch is reloaded, any information exchanged during the initial handshake is not available.
Session 1 : ---------------------------------------------------Target:iqn.2010-11.com.ixia:ixload:iscsi-TG1 Initiator:iqn.2010-11.com.ixia.ixload:initiator-iscsi-35 Up Time:00:00:01:22(DD:HH:MM:SS) Time for aging out:00:00:09:31(DD:HH:MM:SS) ISID:806978696102 Initiator Initiator Target Target Connection IP Address TCP Port IP Address TCPPort ID 10.10.0.53 33432 10.10.0.101 3260 0 Related Commands • show iscsi — displays the currently configured iSCSI settings.
31 Intermediate System to Intermediate System (ISIS) The intermediate system to intermediate system (IS-IS) protocol for IPv4 and IPv6 is supported on the S4810 platform. IS-IS is an interior gateway protocol that uses a shortest-path-first algorithm. IS-IS facilitates the communication between open systems, supporting routers passing both IP and OSI traffic. A router is considered an intermediate system. Networks are partitioned into manageable routing domains, called areas.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 7.5.1.0 Introduced on the E-Series. To perform protocol-support consistency checks on hello packets, use this command. The adjacency-check is enabled by default. If a BFD session goes down indicating that IPv4 or IPv6 connectivity to its neighbor is lost, it does not imply that the adjacency is lost altogether. The hello adjacency runs over Layer 2, and does not require IP connectivity.
Usage Information Version Description 7.5.1.0 Added IPv6 ISIS support. 6.3.1.0 Version 6.3.1.0 Introduced You cannot disable leaking from Level 1 to Level 2. Also, you cannot enable leaking from Level 2 to Level 1. However, you can regulate the rate flow from one level to another using an IP Prefix list. If you do not configure the IP Prefix list, all Level 1 routes are leaked. You can find more information in IETF RFC 2966, Domain-wide Prefix Distribution with Two-Level IS-IS.
• isis password — allows you to configure an authentication password for an interface. clear isis Restart the IS-IS process. All IS-IS data is cleared. S4810 Syntax Parameters clear isis [vrf vrf-name] [tag] {* | database | traffic} vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to restart the IS-IS process corresponding to that VRF. tag (Optional) Enter an alphanumeric string to specify the IS-IS routing tag area.
Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000.
debug isis adj-packets Enable debugging on adjacency-related activity such as hello packets that are sent and received on IS-IS adjacencies. S4810 Syntax debug isis [vrf vrf-name] adj-packets [interface] To turn off debugging, use the no debug isis [vrf vrf-name]adj-packets [interface] command. Parameters vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to enable the debug information on IS-IS for an adjacency tied to that VRF.
To turn off debugging, use the no debug isis [vrf vrf—name] updates [interface] command. Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to enable the debugging information on IS-IS corresponding to that VRF. This information contains local updates tied to the VRF that you specify. This command displays the local LSP debugging details of the current unit.
Parameters vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to enable debugging information on ISIS for CSNP/PSNP packets tied to that VRF. The command displays the SNP (CSNP/PSNP) related debugging information. interface (OPTIONAL) Identifies the interface type slot/port as one of the following: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
Command History This guide is platform-specific. For command information about other platforms,refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 6.3.1.0 Introduced.
Version Description 9.2(0.2) Introduced on the Z9000. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 6.3.1.0 Introduced. default-information originate Generates a default route into an IS-IS routing domain and controls the distribution of default information.
Usage Information When you use this command to redistribute routes into a routing domain, the router becomes an autonomous system (AS) boundary router. An AS boundary router does not always generate a default route into a routing domain. The router still requires its own default route before it can generate one. How a metric value assigned to a default route advertises depends on the metric-style command configuration.
Parameters Defaults Command Modes Command History weight The administrative distance value indicates the reliability of a routing information source. The range is from 1 to 255. (A higher relative value indicates lower reliability. Routes with smaller values are given preference.) The default is 115. ip-address mask (OPTIONAL) Enter the next-hop address in dotted decimal format and enter a mask in either dotted decimal or /prefix format. prefix-list (OPTIONAL) Enter the name of a prefix list name.
Defaults • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Not configured. Command Modes Command History • ROUTER ISIS (for IPv4) • CONFIGURATION-ROUTER-ISIS-ADDRESS-FAMILY-IPV6 (for IPv6) This guide is platform-specific.
static Defaults Command Modes Command History (OPTIONAL) Enter the keyword static for user-configured routing process. Not configured. • ROUTER ISIS (for IPv4) • CONFIGURATION-ROUTER-ISIS-ADDRESS-FAMILY-IPV6 (for IPv6) This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.8.1.0 Added IPv6 ISIS support. 6.3.1.0 Introduced. When you execute this command, IS-IS does not download the route to the routing table if the same route was redistributed into IS-IS routing protocol on the same router. domain-password Set the authentication password for a routing domain.
Related Commands • area-password — configures an IS-IS area authentication password. • isis priority — configures the authentication password for an interface. graceful-restart ietf Enable graceful restart on an IS-IS router. Syntax graceful-restart ietf To return to the default, use the no graceful-restart ietf command. Parameters ietf Enter ietf to enable graceful restart on the IS-IS router. Defaults Graceful restart disabled.
To return to the default, use the no graceful-restart interval command. Parameters minutes Enter the graceful-restart interval minutes. The range is from 1 to 20 minutes. The default is 5 minutes. Defaults 5 minutes Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Related Commands Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.3.1.0 Introduced on the E-Series. graceful-restart t3 — configures the overall wait time before graceful restart completes. graceful-restart t1 Set the graceful restart wait time before unacknowledged restart requests are generated.
graceful-restart t2 Configure the wait time for the graceful restart timer T2 that a restarting router uses as the wait time for each database to synchronize. Syntax graceful-restart t2 {level-1 | level-2} seconds To return to the default, use the no graceful-restart t2 command. Parameters level-1, level-2 Enter the keywords level-1 or level-2 to identify the database instance type to which the wait interval applies. seconds Enter the gracefule-restart t2 time in seconds.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.3.1.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. Usage Information IS-IS hellos are padded to the full maximum transmission unit (MTU) size. Padding IS-IS Hellos (IIHS) to the full MTU provides early error detection of large frame transmission problems or mismatched MTUs on adjacent interfaces.
To return to the default values, use the no ignore-lsp-errors command. Defaults In IS-IS, the default deletes LSPs with internal checksum errors (no ignore-lsp-errors). Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
Usage Information Version Description 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.5.1.0 Introduced. To assign a network entity title to enable IS-IS, use the net command. This command accepts even if an IP address is not configured. This command is cached in the L3 Manager till the IP address is configured. When the IP address configuration reaches the L3Manager, the circuit add message is sent to IS-IS. NOTE: IP address is not mandatory for forming IS-IS adjacency.
To establish adjacencies and establish dynamic routing, enable routing on one or more interfaces. You can configure only one IS-IS routing process to perform Level 2 routing. A level-1-2 designation performs Level 1 and Level 2 routing at the same time. Related Commands • net — configures an IS-IS network entity title (NET) for the routing process. • is-type — assigns a type for a given area. isis circuit-type Configure the adjacency type on interfaces.
Only configure interfaces as Level 1 or Level 2 on routers that are between areas (for example, a Level 1-2 router) to prevent the software from sending unused hello packets and wasting bandwidth. isis csnp-interval Configure the IS-IS complete sequence number PDU (CSNP) interval on an interface. Syntax isis csnp-interval seconds [level-1 | level-2] To return to the default values, use the no isis csnp-interval [seconds] [level-1 | level-2] command.
To return to the default values, use the no isis hello-interval [seconds] [level-1 | level-2] command. Parameters seconds Allows you to set the length of time between hello packet transmissions. The range is from 1 to 65535. The default is 10. level-1 (OPTIONAL) Select this value to configure the hello interval for Level 1. This value is the default. level-2 (OPTIONAL) Select this value to configure the hello interval for Level 2.
level-2 (OPTONAL) Select this value to configure the hello multiplier independently for Level 2 adjacencies. Defaults multiplier = 3; level-1 (if not otherwise specified) Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
Usage Information Hello PDUs are “padded” only when both the global and interface padding options are ON. Turning either one OFF disables padding for the corresponding interface. Related Commands hello padding — turns ON or OFF padding for LAN and point-to-point hello PDUs. isis ipv6 metric Assign metric to an interface for use with IPv6 information.
isis metric Assign a metric to an interface. Syntax isis metric default-metric [level-1 | level-2] To return to the default values, use the no isis metric [default-metric] [level-1 | level-2] command. Parameters default-metric Metric assigned to the link and used to calculate the cost from each other router via the links in the network to other destinations. You can configure this metric for Level 1 or Level 2 routing. The range is from 0 to 16777215 irrespective of the metric style. The default is 10.
isis network point-to-point Enable the software to treat a broadcast interface as a point-to-point interface. Syntax isis network point-to-point To disable the feature, use the no isis network point-to-point command. Defaults Not enabled. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. To protect your network from unauthorized access, use this command to prevent unauthorized routers from forming adjacencies.
Usage Information Version Description 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. You can configure priorities independently for Level 1 and Level 2. Priorities determine which router on a LAN is the designated router. Priorities are advertised within hellos. The router with the highest priority becomes the designated intermediate system (DIS). NOTE: Routers with a priority of 0 cannot be a designated router.
If you are configuring only one area in your network, you do not need to run both Level 1 and Level 2 routing algorithms. You can configure the IS type as Level 1. log-adjacency-changes Generate a log messages for adjacency state changes. Syntax log-adjacency-changes To disable this function, use the no log-adjacency-changes command. Defaults Adjacency changes are not logged. Command Modes ROUTER ISIS Command History This guide is platform-specific.
interval seconds Enter the maximum number of seconds between LSP generations. The range is from 0 to 120 seconds. The default is 5 seconds. initial_wait_interval seconds (OPTIONAL) Enter the initial wait time, in seconds, before running the first LSP generation. The range is from 0 to 120 seconds. The default is 1 second. second_wait_interv al seconds (OPTIONAL) Enter the wait interval, in seconds, between the first and second LSP generation. The range is from 0 to 120 seconds.
NOTE: The appropriate interface circuit is brought down and removed. Defaults 1497 bytes. Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.5.1.0 Added support for LSP Throttling Enhancement. The refresh interval determines the rate at which route topology information is transmitted preventing the information from becoming obsolete.
Usage Information To configure the number of area addresses on router, use this command. This value must be consistent with routers in the same area, otherwise the router forms only Level 2 adjacencies. The value must be same among all the routers to form Level 1 adjacencies. max-lsp-lifetime Set the maximum time that link-state packets (LSPs) exist without being refreshed. Syntax max-lsp-lifetime seconds To restore the default time, use the no max-lsp-lifetime command.
To return to the default values, use the no maximum-paths command. Parameters Defaults Command Modes Command History number Enter a number as the maximum number of parallel paths an IP routing installs in a routing table. The range is from 1 to 64. The default is 4. 4 • ROUTER ISIS (for IPv4) • CONFIGURATION-ROUTER-ISIS-ADDRESS-FAMILY-IPV6 (for IPv6) This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
level-2 Enables the metric style on Level 2. Defaults narrow; if no Level is specified, Level-1 and Level-2 are configured. Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.12.0 Introduced on the S4810. 7.8.1.0 Introduced. net To configure an IS-IS network entity title (NET) for a routing process, use this mandatory command. If you did not configure a NET, the IS-IS process does not start. Syntax net network-entity-title To remove a net, use the no net network-entity-title command.
Parameters interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128.
Defaults Command Modes Command History metric metric-value (OPTIONAL) Assign a value to the redistributed route. The range is from 0 to 16777215. The default is 0. Use a value that is consistent with the destination protocol. metric-type {external | internal} (OPTIONAL) The external link type associated with the default route advertised into a routing domain. Specify one of the following: • external • internal level-1 (OPTIONAL) Routes are independently redistributed into IS-IS as Level 1 routes.
Redistributed routing information is filtered with the distribute-list out command to ensure that the routes are properly passed to the receiving routing protocol. How a metric value assigned to a redistributed route is advertised depends on how on the configuration of the metric-style command. If the metric-style command is set for Narrow or Transition mode and the metric value in the redistribute command is set to a number higher than 63, the metric value advertised in LSPs is 63.
Command Modes Command History • ROUTER ISIS (for IPv4) • CONFIGURATION-ROUTER-ISIS-ADDRESS-FAMILY-IPV6 (for IPv6) This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
metric-type {external | internal} (OPTIONAL) The external link type associated with the default route advertised into a routing domain. The two options are: • external • internal level-1 (OPTIONAL) Routes are independently redistributed into IS-IS as Level 1 routes. level-1-2 (OPTIONAL) Routes are independently redistributed into IS-IS as Level-1-2 routes. level-2 (OPTIONAL) Routes are independently redistributed into IS-IS as Level 2 routes. This setting is the default.
router isis Allows you to enable the IS-IS routing protocol and to specify an IP IS-IS process. S4810 Syntax router isis [vrf vrf-name] [tag] To disable IS-IS routing, use the no router isis [tag] command. Parameters vrf vrf-name Enter the keyword vrf followed by the name of the VRF to enable the IS-IS routing protocol and to specify an IP IS-IS process on that VRF. tag (OPTIONAL) This is a unique name for a routing process. A null tag is assumed if the tag option is not specified.
set-overload-bit To set the overload bit in zeroth fragment of non-pseudonode LSPs on the router, configure the router. This setting prevents other routers from using it as an intermediate hop in their shortest path first (SPF) calculations. Syntax set-overload-bit To return to the default values, use the no set-overload-bit command. Defaults Not set. Command Modes Command History • ROUTER ISIS (for IPv4) • CONFIGURATION-ROUTER-ISIS-ADDRESS-FAMILY-IPV6 (for IPv6) This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example (RouterIsis) Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.1 Introduced on the S4810.
NOTE: If you do not specify this option, the IS-IS link state database corresponding to the default VRF are displayed. Command Modes Command History level-1 (OPTIONAL) Displays the Level 1 IS-IS link-state database. level-2 (OPTIONAL) Displays the Level 2 IS-IS link-state database. local (OPTIONAL) Displays local link-state database information. detail (OPTIONAL) Displays the detailed link-state database information of each LSP when specified. If not specified, a summary displays.
Field Description The last octet is the LSP number. An LSP is divided into multiple LSP fragments if there is more data than cannot fit in a single LSP. Each fragment has a unique LSP number. An * after the LSPID indicates that the system originates an LSP where this command was issued. Example LSP Seq Num This value is the sequence number for the LSP that allows other systems to determine if they have received the latest information from the source.
LSPID LSP Seq Num LSP Checksum LSP Holdtime ATT/P/OL ISIS.00-00 * 0x0000002D 0xB2CD 1075 0/0/0 Area Address: 49.0000.0001 NLPID: 0xCC 0x8E IP Address: 10.1.1.1 IPv6 Address: 1011::1 Topology: IPv4 (0x00) IPv6 (0x8002) Metric: 10 IS OSPF.00 Metric: 10 IS (MT-IPv6) OSPF.00 Metric: 10 IP 10.1.1.0 255.255.255.0 Metric: 10 IP 15.1.1.0 255.255.255.0 Metric: 20 IP 10.3.3.0 255.255.255.
Example Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.3.1.0 Introduced on the E-Series.
Example Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. Dell#show isis hostname System Id Dynamic Name Static Name *F100.E120.0013 Force10 ISIS Dell# show isis interface Display detailed IS-IS interface status and configuration information.
Example Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. Dell>show isis int TenGigabitEthernet 1/7 is up, line protocol is up MTU 1497, Encapsulation SAP Routing Protocol: IS-IS Circuit Type: Level-1-2 Interface Index 37847070, Local circuit ID 1 Level-1 Metric: 10, Priority: 64, Circuit ID: systest-3.01 Hello Interval: 10, Hello Multiplier: 3, CSNP Interval: 10 Number of active level-1 adjacencies: 1 Level-2 Metric: 10, Priority: 64, Circuit ID: systest-3.
• Command Modes Command History • EXEC • EXEC Privilege For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500.
Topology: IPv4 IPv6 , Common (IPv4 IPv6 ) Adjacency being used for MTs: IPv4 IPv6 Dell# show isis protocol Display IS-IS routing information. S4810 Syntax Parameters Command Modes Command History show isis [vrf vrf-name] protocol vrf vrf-name • EXEC • EXEC Privilege (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to display ISIS routing information corresponding to that VRF. This guide is platform-specific.
Multi Topology Routing is enabled in transition mode. Dell# show isis traffic This command allows you to display IS-IS traffic interface information. S4810 Syntax show isis [vrf vrf-name] traffic [interface] Parameters Command Modes Command History vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to display ISIS traffic interface information corresponding to that VRF.
Example Item Description PTP Hellos (sent/ rcvd) Displays the number of point-to-point Hellos sent and received. Level-1/Level-2 LSPs sourced (new/refresh) Displays the number of new and refreshed LSPs. Level-1/Level-2 LSPs flooded (sent/rcvd) Displays the number of flooded LSPs sent and received. Level-1/Level-2 LSPs CSNPs (sent/ rcvd) Displays the number of CSNP LSPs sent and received. Level-1/Level-2 LSPs PSNPs (sent/ rcvd) Displays the number of PSNP LPSs sent and received.
To restore default values, use the no spf-interval [level-l | level-2] interval seconds [initial_wait_interval seconds [second_wait_interval seconds]] command. Parameters Defaults level-l (OPTIONAL) Enter the keyword level-1 to apply the configuration to Level-1 SPF calculations. level-2 (OPTIONAL) Enter the keyword level-2 to apply the configuration to Level-2 SPF calculations. interval seconds Enter the maximum number of seconds between SPF calculations. The range is from 0 to 120 seconds.
interval reaches the maximum wait time specified (interval seconds). After the network calms down and there are no triggers for two times the maximum interval, fast behavior is restored (the initial wait time).
32 Link Aggregation Control Protocol (LACP) This chapter contains commands for Dell Networks’s implementation of the link aggregation control protocol (LACP) for creating dynamic link aggregation groups (LAGs) — known as “port-channels” in the Dell Networking operating software. The LACP commands in this chapter are supported by Dell Networking OS on the S4810 platform. NOTE: For static LAG commands, refer to Port Channel Commands in the Interfaces chapter), based on the standards specified in the IEEE 802.
Related Commands Version Description 6.2.1.1 Introduced on the E-Series. show lacp — displays the LACP configuration. debug lacp Debug LACP (configuration, events, and so on). S4810 Syntax debug lacp [config | events | pdu [interface-type [in | out]]] To disable LACP debugging, use the no [config | events | pdu [interface-type [in | out]]] command. Parameters config (OPTIONAL) Enter the keyword config to debug the LACP configuration.
Version Description 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. lacp long-timeout Configure a long timeout period (30 seconds) for an LACP session. S4810 Syntax lacp long-timeout To reset the timeout period to a short timeout (1 second), use the no lacp long-timeout command.
lacp port-priority To influence which ports will be put in Standby mode when there is a hardware limitation that prevents all compatible ports from aggregating, configure the port priority. S4810 Syntax lacp port-priority priority-value To return to the default setting, use the no lacp port-priority priority-value command. Parameters priority-value Enter the port-priority value. The higher the value number, the lower the priority. The range is from 1 to 65535. The default is 32768.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
show lacp Display the LACP matrix. S4810 Syntax Parameters Defaults Command Modes Command History show lacp port-channel-number [sys-id | counters] port-channelnumber Enter a port-channel number. The range is from 1 to 128. sys-id (OPTIONAL) Enter the keywords sys-id and the value that identifies a system. counters (OPTIONAL) Enter the keyword counters to display the LACP counters. Without a Port Channel specified, the command clears all Port Channel counters.
Dell# Example (Sys-id) Oper: State BCEGIKNP Key 1 Priority 128 Dell#show lacp 1 sys-id Actor System ID: Priority 32768, Address 0001.e800.a12b Partner System ID: Priority 32768, Address 0001.e801.
33 Layer 2 This chapter describes commands to configure Layer 2 features. This chapter contains the following sections: • MAC Addressing Commands • Virtual LAN (VLAN) Commands • Far-End Failure Detection (FEFD) The VLAN commands are supported on all the S4810 platform. MAC Addressing Commands The following commands are related to configuring, managing, and viewing MAC addresses. clear mac-address-table Clear the MAC address table of all MAC address learned dynamically.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Added support for sticky MAC addresses. 8.3.11.1 Introduced on the Z9000. 8.5.1.
Related Commands Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. mac learning-limit — sets the MAC address learning limits for a selected interface. show mac-address-table aging-time — displays the MAC aging time. mac-address-table static Associate specific MAC or hardware addresses to an interface and VLANs.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 9.1(0.0) Added support for output range parameter for S4810 and Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. For information about the specific trap sent and the corresponding Syslog, refer to the SNMP Traps chapter. mac-address-table station-move refresh-arp Ensure that address resolution protocol (ARP) refreshes the egress interface when a station move occurs due to a topology change.
Defaults dynamic (OPTIONAL) Enter the keyword dynamic to allow aging of MACs even though a learning limit is configured. station-moveviolation (OPTIONAL) Enter the keywords station-move to allow a station move on learned MAC addresses. • On S-Series, the default behavior is dynamic. NOTE: “Static” means manually entered addresses, which do not age. Command Modes INTERFACE Command History This guide is platform-specific.
When a channel member is added to a port-channel and there is not enough ACL CAM space, the MAC limit functionality on that port-channel is undefined. When this occurs, un-configure the existing configuration first and then reapply the limit with a lower value. Related Commands mac learning-limit mac-address-sticky — Replaces deprecated no-station-move parameter. show mac learning-limit — displays MAC learning-limit configuration.
mac learning-limit mac-address-sticky Maintain the dynamically learned mac addresses as sticky MAC addresses on the selected port. S4810 Syntax mac learning-limit mac-address-sticky To convert the sticky MAC addresses to dynamic MAC addresses, use the no mac learning-limit command. Parameters mac-address-sticky Configures the dynamic MAC addresses as sticky on an interface. Defaults none Command Modes INTERFACE Command History This guide is platform-specific.
shutdown-original Enter the keywords shutdown-original to shut down the original interface and generate a syslog message. Defaults none Command Modes INTERFACE (conf-if-interface-slot/port) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.
Version Description 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 7.5.1.0 Introduced on the E-Series. show cam mac linecard (count) Display the content addressable memory (CAM) size and the portions allocated for MAC addresses and for MAC ACLs.
show cam mac linecard (dynamic or static) Display the CAM size and the portions allocated for MAC addresses and for MAC ACLs. S4810 Syntax Parameters Command Modes Command History show cam mac linecard slot port-set port-pipe [address mac_addr | dynamic | interface interface | static | vlan vlan-id] linecard slot (REQUIRED) Enter the keyword linecard then a slot number to select the linecard for which to gather information.
Example Dell#show cam mac linecard 1 port-set 0 Port - (TableID) assignments: 00(01) 01(01) 02(01) 03(01) 04(01) 05(01) 06(01) 07(01) 08(01) 09(01) 10(01) 11(01) 12(01) 13(01) 14(01) 15(01) 16(01) 17(01) 18(01) 19(01) 20(01) 21(01) 22(01) 23(01) Index Table ID VlanId Mac Address Region Interface 0 1 0 00:01:e8:0d:b7:3b LOCAL_DA 1e000 1 1 0 00:01:e8:0d:b7:3a LOCAL_DA 1e000 101 0 0 00:01:e8:00:04:00 SYSTEM_STATIC 01c05 102 0 0 01:80:00:00:00:00 SYSTEM_STATIC 01c05 103 0 0 01:00:0c:cc:cc:cc SYSTEM_STATIC 01c0
• Command Modes Command History For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. interface interfacetype (OPTIONAL) Instead of entering the keyword interface then the interface type, slot/port information, as above, you can enter the interface type, then just a slot number. vlan vlan-id (OPTIONAL) Enter the keyword vlan then the VLAN ID to display the MAC address assigned to the VLAN. The range is 1 to 4094.
Column Heading Description State Example Lists if the MAC address is in use (Active) or not in use (Inactive). Dell(conf)#do show mac-address-table Codes: *N - VLT Peer Synced MAC VlanId Mac Address Type 2 00:00:00:00:00:01 Dynamic (N) 2 00:00:00:00:00:02 Dynamic (N) 2 00:00:00:00:00:03 Dynamic 2 00:00:00:00:00:04 Dynamic Usage Information Interface Po 128 Po 10 Po 100 Po 10 State Active Active Active Active The following describes the show mac-address-table command shown in the following example.
show mac-address-table aging-time Display the aging times assigned to the MAC addresses on the switch. S4810 Syntax Parameters Command Modes Command History show mac-address-table aging-time [vlan vlan-id] vlan vlan-id • EXEC • EXEC Privilege (OPTIONAL) Enter the keyword vlan then the VLAN ID to display the MAC address assigned to the VLAN. The range is from 1 to 4094. This guide is platform-specific.
vlan vlan-id Command Modes Command History • EXEC • EXEC Privilege • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. (OPTIONAL) Enter the keyword vlan then the VLAN ID to display the MAC address assigned to the VLAN. The range is from 1 to 4094. This guide is platform-specific.
Parameters Command Modes Command History violate-action (OPTIONAL) Enter the keywords violate-action to display the MAC learning limit violation status. detail (OPTIONAL) Enter the keyword detail to display the MAC learning limit in detail. interface interface (OPTIONAL) Enter the keyword interface with the following keywords and slot/port or number information: • EXEC • EXEC Privilege • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128.
Virtual LAN (VLAN) Commands The following commands configure and monitor virtual LANs (VLANs). VLANs are a virtual interface and use many of the same commands as physical interfaces. You can configure an IP address and Layer 3 protocols on a VLAN called Inter-VLAN routing. FTP, TFTP, ACLs and SNMP are not supported on a VLAN. Occasionally, while sending broadcast traffic over multiple Layer 3 VLANs, the VRRP state of a VLAN interface may continually switch between Master and Backup.
default-vlan disable Disable the default VLAN so that all switchports are placed in the Null VLAN until they are explicitly configured as a member of another VLAN. S4810 Defaults Enabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. Usage Information To display information about a named VLAN, enter the show vlan command with the name parameter or the show interfaces description command. Related Commands interface vlan — configures a VLAN.
show vlan Display the current VLAN configurations on the switch. S4810 Syntax Parameters Command Modes Command History show vlan [brief | id vlan-id | name vlan-name] brief (OPTIONAL) Enter the keyword brief to display the following information: • VLAN ID • VLAN name (left blank if none is configured) • Spanning Tree Group ID • MAC address aging time • IP address id vlan-id (OPTIONAL) Enter the keyword id then a number from 1 to 4094. Only information on the VLAN specified is displayed.
Column Heading Description (Column 1 — no heading) asterisk symbol (*) = Default VLAN • G = GVRP VLAN • P = primary VLAN • C = community VLAN • I = isolated VLAN • O = OpenFlow NUM Displays existing VLAN IDs. Status Displays the word Inactive for inactive VLANs and the word Active for active VLANs.
Example (VLAN ID) 5 Active T Po20(Te 13/6) 6 Active U Po3(Te 13/4) 7 Active T Po20(Te 13/6) P 100 Active T Po1(Te 1/1) C 101 I 102 Dell# Inactive T Te 1/3 Inactive T Te 1/4 T Te 13/7 U Te 13/3 T Po20(Te 13/6) T Te 13/7 T Te 13/7 U Te 13/5 T Te 1/2 Dell# show vlan id 40 Codes: Q: U x G - * - Default VLAN, G - GVRP VLANs Untagged, T - Tagged Dot1x untagged, X - Dot1x tagged GVRP tagged, M - Vlan-stack NUM 40 Status Description Q Ports Active M Te 13/47 Dell#show vlan id 41 Codes: Q: U x G - *
Example (OpenFlow instance) * O O O Related Commands NUM 1 3 6 8 12 Status Inactive Inactive Inactive Inactive Inactive Description Q Ports O Te 1/10 vlan-stack compatible — enables the Stackable VLAN feature on the selected VLAN. interface vlan — configures a VLAN. tagged Add a Layer 2 interface to a VLAN as a tagged interface. S4810 Syntax tagged interface To remove a tagged interface from a VLAN, use the no tagged interface command.
Usage Information When you use the no tagged command, the interface is automatically placed in the Default VLAN as an untagged interface unless the interface is a member of another VLAN. If the interface belongs to several VLANs, remove it from all VLANs to change it to an untagged interface. Tagged interfaces can belong to multiple VLANs, while untagged interfaces can only belong to one VLAN at a time. Related Commands interface vlan — configures a VLAN.
Usage Information Version Description pre-6.2.1.1 Introduced on the E-Series. When this command is configured, the VLAN is operationally UP if any of the interfaces specified in the track ip command are operationally UP, and the VLAN is operationally DOWN if none of the tracking interfaces are operationally UP. If the track ip command is not configured, the VLAN's Layer 3 operational state depends on all the members of the VLAN.
Usage Information Version Description 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. Untagged interfaces can only belong to one VLAN. In the Default VLAN, you cannot use the no untagged interface command. To remove an untagged interface from all VLANs, including the Default VLAN, enter INTERFACE mode and use the no switchport command.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.12.0 Introduced on the S4810.
Usage Information Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.12.0 Introduced on the S4810. When you enter no fefd for an interface and fefd-global, FEFD is enabled on the interface because the no fefd command is not retained in the configuration file. To keep the interface FEFD disabled when the global configuration changes, use the fefd reset command.
fefd interval Set an interval between control packets. S4810 Syntax fefd interval seconds To return to the default value, use the no fefd interval command. Parameters seconds Enter a number as the time between FEFD control packets. The range is from 3 to 300 seconds. The default is 15 seconds. Defaults 15 seconds Command Modes INTERFACE Command History This guide is platform-specific.
Defaults normal Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Legacy E-Series command.
Version Description Legacy E-Series command. Related Commands • fefd — enables far-end failure detection. fefd-global interval Configure an interval between FEFD control packets. S4810 Syntax fefd-global interval seconds To return to the default value, use the no fefd-global interval command. Parameters seconds Enter a number as the time between FEFD control packets. The range is from 3 to 300 seconds. The default is 15 seconds.
Parameters interval seconds Enter the keyword interval followed by the number of seconds to wait between FEFD control packets. Range is from 3 to 300 seconds. Default is 15 seconds. normal (OPTIONAL) Enter the keywords mode normal to change the link state to “unknown” when a far-end failure the software detects on that interface. When the interface is placed in “unknown” state, the software brings down the line protocol. The default is Normal mode.
Command Modes Command History • EXEC • EXEC Privilege • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Te 5/5 Te 5/6 Te 5/7 Te 5/8 Te 5/9 Te 5/10 Te 5/11 Dell# Related Commands Aggressive Aggressive Aggressive Aggressive Aggressive NA Aggressive 10 10 10 10 10 NA 10 Admin Shutdown Admin Shutdown Admin Shutdown Admin Shutdown Admin Shutdown Locally disabled Err-disabled • fefd — enables far-end failure detection. • fefd disable — disables FEFD on an interface only. • fefd-global — enables FEFD globally on the system.
34 Link Layer Discovery Protocol (LLDP) The link layer discovery protocol (LLDP) advertises connectivity and management from the local station to the adjacent stations on an IEEE 802 LAN. This chapter contains the following sections: • LLPD Commands • LLDP-MED Commands LLDP facilitates multi-vendor interoperability by using standard management tools to discover and make available a physical topology for network management.
Command Modes CONFIGURATION (conf-lldp) and INTERFACE (conf-if-interface-lldp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. advertise management-tlv Advertise management TLVs (Type, Length, Value).
Usage Information The command options management-address,system-capabilities, system-description, and system-name can be invoked individually or together, in any sequence. advertise management-tlv (Interface) Advertise management type, length, values (TLVs) to the specified interface.
Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.
Version Description 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. debug lldp interface To display timer events, neighbor additions or deletions, and other information about incoming and outgoing packets, enable LLDP debugging. S4810 Syntax debug lldp interface {interface | all}{events | packet {brief | detail} {tx | rx | both}} To disable debugging, use the no debug lldp interface {interface | all}{events} {packet {brief | detail} {tx | rx | both}} command.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. disable Enable or disable LLDP. S4810 Syntax disable To enable LLDP, use the no disable command. Defaults Enabled, that is no disable.
hello Configure the rate at which the LLDP control packets are sent to its peer. S4810 Syntax hello seconds To revert to the default, use the no hello seconds command. Parameters seconds Enter the rate, in seconds, at which the control packets are sent to its peer. The rate is from 5 to 180 seconds. The default is 30 seconds. Defaults 30 seconds Command Modes CONFIGURATION (conf-lldp) and INTERFACE (conf-if-interface-lldp) Command History This guide is platform-specific.
Usage Information Version Description 9.2(0.2) Introduced on the Z9000 and S4810. To enable LLDP on the management interface, use the no disable command in LLDP-MANAGEMENTINTERFACE mode (conf-lldp-mgmtIf). mode To receive or transmit, set LLDP. S4810 Syntax mode {tx | rx} To return to the default, use the no mode {tx | rx} command. Parameters tx Enter the keyword tx to set the mode to transmit. rx Enter the keyword rx to set the mode to receive. Defaults Both transmit and receive.
multiplier Set the number of consecutive misses before LLDP declares the interface dead. S4810 Syntax multiplier integer To return to the default, use the no multiplier integer command. Parameters integer Enter the number of consecutive misses before the LLDP declares the interface dead. The range is from 2 to 10. Defaults 4 x hello Command Modes CONFIGURATION (conf-lldp) and INTERFACE (conf-if-interface-lldp) Command History This guide is platform-specific.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. protocol lldp (Interface) Enter the LLDP protocol in INTERFACE mode.
show lldp neighbors Display LLDP neighbor information for all interfaces or a specified interface. S4810 Syntax Parameters show lldp neighbors [interface] [detail] interface detail (OPTIONAL) Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
show lldp statistics Display the LLDP statistical information. S4810 Syntax show lldp statistics Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.11.
show running-config lldp Display the current global LLDP configuration. S4810 Syntax show running-config lldp Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
• LLDP-MED Endpoint Device — any device that is on an IEEE 802 LAN network edge, can communicate using IP, and uses the LLDP-MED framework. • LLDP-MED Network Connectivity Device — any device that provides access to an IEEE 802 LAN to an LLDP-MED endpoint device, and supports IEEE 802.1AB (LLDP) and TIA-1057 (LLDP-MED). The Dell Networking system is an LLDP-MED network connectivity device.
Related Commands protocol lldp (Configuration) — enables LLDP globally. debug lldp interface — debugs LLDP. show lldp neighbors — displays the LLDP neighbors. advertise med guest-voice-signaling To advertise a separate limited voice service for a guest user when the guest voice control packets use a separate network policy than the voice data, configure the system.
advertise med location-identification To advertise a location identifier, configure the system. S4810 Syntax advertise med location-identification {coordinate-based value | civic-based value | ecs-elin value} To return to the default, use the no advertise med location-identification {coordinate-based value | civic-based value | ecs-elin value} command. Parameters coordinate-based value Enter the keywords coordinate-based then the coordinated based location in hexadecimal value of 16 bytes.
advertise med power-via-mdi To advertise the Extended Power via MDI TLV, configure the system. S4810 Syntax advertise med power-via-mdi To return to the default, use the no advertise med power-via-mdi command. Defaults unconfigured. Command Modes CONFIGURATION (conf-lldp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
priority-tagged number Enter the keywords priority-tagged then the Layer 2 priority. The range is from 0 to 7. Defaults unconfigured. Command Modes CONFIGURATION (conf-lldp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series.
Related Commands Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series and E-Series. debug lldp interface — debugs LLDP. show lldp neighbors — displays the LLDP neighbors. advertise med video-signaling To advertise video control packets that use a separate network policy than video data, configure the system.
Related Commands Version Description 7.6.1.0 Introduced on the C-Series and E-Series. debug lldp interface — debugs LLDP. show lldp neighbors — displays the LLDP neighbors. advertise med voice To advertise a dedicated IP telephony handset or other appliances supporting interactive voice services, configure the system.
advertise med voice-signaling To advertise when voice control packets use a separate network policy than voice data, configure the system. S4810 Syntax advertise med voice-signaling {vlan-id layer2_priority DSCP_value} | {priority-tagged number} To return to the default, use the no advertise med voice-signaling {vlan-id layer2_priority DSCP_value} | {priority-tagged number} command. Parameters vlan-id Enter the VLAN ID. The range is from 1 to 4094.
35 Microsoft Network Load Balancing Network Load Balancing (NLB) is a clustering functionality that is implemented by Microsoft on Windows 2000 Server and Windows Server 2003 operating systems. Microsoft NLB clustering allows multiple servers running Microsoft Windows to be represented by one MAC and one IP address to provide transparent failover and load-balancing.
Related Commands clear arp-cache — clears dynamic ARP entries from the ARP table. show arp — displays the ARP table. mac-address-table static (for Multicast MAC Address) For multicast mode of network load balancing (NLB), configure a static multicast MAC address, associate the multicast MAC address with the VLAN used to switch Layer 2 multicast traffic, and add output ports that will receive multicast streams on the VLAN.
Example (Multicast) Version Description 9.3(0.0) Added support for multicast MAC address on the MXL platform. mac-address-table static 01:00:5E:01:00:01 {multicast vlan 2 output—range Te 1/2,Te 1/3} ip vlan-flooding Enable unicast data traffic flooding on VLAN member ports. Syntax ip vlan-flooding To disable, use the no ip vlan-flooding command. Command Modes Command History CONFIGURATION Version 9.3(0.0) Introduced on the S4810, S4820T, S6000, Z9000, and MXL platforms Version Description 9.
36 Multicast Source Discovery Protocol (MSDP) Multicast source discovery protocol (MSDP) connects multiple PIM Sparse-Mode (PIM-SM) domains together. MSDP peers connect using TCP port 639. Peers send keepalives every 60 seconds. A peer connection is reset after 75 seconds if no MSDP packets are received. MSDP connections are parallel with MBGP connections. The Dell Networking operating system supports MSDP commands on the S4810 platform.
clear ip msdp sa-cache Clears the entire source-active cache, the source-active entries of a particular multicast group, rejected, or local source-active entries. S4810 Syntax Parameters clear ip msdp sa-cache [group-address | rejected-sa | local] group-address Enter the group IP address in dotted decimal format (A.B.C.D.).
peer-address Enter the IP address of the MSDP peer. Defaults Without any options, this command clears the entire source-active cache. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 6.2.1.1 Introduced ip msdp cache-rejected-sa Enable an MSDP cache for the rejected source-active entries.
ip msdp default-peer Define a default peer from which to accept all source-active (SA) messages. S4810 Syntax ip msdp default-peer peer address [list name] To remove the default peer, use the no ip msdp default-peer {peer address} list name command. Parameters peer address Enter the peer address in a dotted decimal format (A.B.C.D.) list name Enter the keywords list name and specify a standard access list that contains the RP address that should be treated as the default peer.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 6.2.1.
Usage Information An MSDP mesh group is a mechanism for reducing SA flooding, typically in an intra-domain setting. When some subset of a domain’s MSDP speakers are fully meshed, they can be configured into a mesh-group. If member X of a mesh-group receives a SA message from an MSDP peer that is also a member of the meshgroup, member X accepts the SA message and forwards it to all of its peers that are not part of the meshgroup.
ip msdp peer Configure an MSDP peer. S4810 Syntax ip msdp peer peer address [connect-source] [description] [sa-limit number] To remove the MSDP peer, use the no ip msdp peer peer address [connect-source interface] [description name] [sa-limit number] command. Parameters peer address Enter the peer address in a dotted decimal format (A.B.C.D.).
Usage Information The connect-source option is used to supply a source IP address for the TCP connection. When an interface is specified using the connect-source option, the primary configured address on the interface is used. If the total number of SA messages received from the peer is already larger than the limit when this command is applied, those SA messages continue to be accepted. To enforce the limit in such situation, use the clear ip msdp peer command to reset the peer.
ip msdp sa-filter Permit or deny MSDP source active (SA) messages based on multicast source and/or group from the specified peer. S4810 Syntax ip msdp sa-filter {in | out} peer-address list [access-list name] Remove this configuration using the no ip msdp sa-filter {in | out} peer address list [access-list name] command. Parameters in Enter the keyword in to enable incoming SA filtering. out Enter the keyword out to enable outgoing SA filtering.
Defaults 50000 Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 6.2.1.1 Introduced ip multicast-msdp Enable MSDP. S4810 Syntax ip multicast-msdp To exit MSDP, use the no ip multicast-msdp command. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific.
Parameters Defaults peer peer address Enter the keyword peer then the peer address in a dotted decimal format (A.B.C.D.). sa-cache Enter the keywords sa-cache to display the Source-Active cache. summary Enter the keyword summary to display an MSDP peer summary. Not configured. Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
show ip msdp sa-cache rejected-sa Display the rejected SAs in the SA cache. S4810 Syntax show ip msdp sa-cache rejected-sa Defaults none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.
37 Multiple Spanning Tree Protocol (MSTP) Multiple spanning tree protocol (MSTP), as implemented by the Dell Networking operating system, conforms to IEEE 802.1s. This command supports the Dell Networking S4810 platform. debug spanning-tree mstp Enable debugging of the multiple spanning tree protocol and view information on the protocol.
Example Version Description 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series.
Related Commands protocol spanning-tree mstp — enters MULTIPLE SPANNING TREE mode. forward-delay The amount of time the interface waits in the Blocking State and the Learning State before transitioning to the Forwarding State. S4810 Syntax forward-delay seconds To return to the default setting, use the no forward-delay command. Parameters seconds Enter the number of seconds the interface waits in the Blocking State and the Learning State before transiting to the Forwarding State.
hello-time Set the time interval between generation of MSTB bridge protocol data units (BPDUs). S4810 Syntax hello-time seconds To return to the default value, use the no hello-time command. Parameters seconds Enter a number as the time interval between transmission of BPDUs. The range is from 1 to 10. The default is 2 seconds. Defaults 2 seconds Command Modes MULTIPLE SPANNING TREE Command History This guide is platform-specific.
Parameters max-age Enter a number of seconds the Dell Networking OS waits before refreshing configuration information. The range is from 6 to 40. The default is 20 seconds. Defaults 20 seconds Command Modes MULTIPLE SPANNING TREE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Valid priority values are: 0, 4096, 8192, 12288, 16384, 20480, 24576, 28672, 32768, 36864, 40960, 45056, 49152, 53248, 57344, and 61440. All other values are rejected. Defaults default bridge-priority is 32768. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.5.1.0 Introduced. Usage Information For two MSTP switches to be within the same MSTP region, the switches must share the same region name (including matching case). Related Commands msti — maps the VLAN(s) to an MST instance.
Usage Information Version Description pre-6.2.1.1 Introduced on the E-Series. MSTP is not enabled when you enter MULTIPLE SPANNING TREE mode. To enable MSTP globally on the switch, enter the no disable command while in MULTIPLE SPANNING TREE mode. For more information about the multiple spanning tree protocol, refer to the Dell Networking OS Configuration Guide. Example Dell(conf)#protocol spanning-tree mstp Dell(config-mstp)#no disable Related Commands disable — disables multiple spanning tree.
Usage Information For two MSTP switches to be within the same MST region, the switches must share the same revision number. Related Commands msti — maps the VLAN(s) to an MST instance. name — assigns the region name to the MST region. show config View the current configuration for the mode. Only non-default values are shown. S4810 Syntax show config Command Modes MULTIPLE SPANNING TREE Command History This guide is platform-specific.
show spanning-tree mst configuration View the multiple spanning tree configuration. S4810 Syntax Command Modes Command History show spanning-tree mst configuration • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
guard Command Modes Command History • EXEC • EXEC Privilege (Optional) Enter the keyword guard to display the type of guard enabled on an MSTP interface and the current port state. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Designated bridge has priority 16384, address 0001.e800.0a:5c Designated port id is 128.89, designated path cost Number of transitions to forwarding state 3 BPDU (Mrecords): sent 7, received 1103 The port is not in the portfast mode Example (EDS and LBK) The bold line shows the loopback BPDU inconsistency (LBK_INC). Dell#show spanning-tree msti 0 brief MSTI 0 VLANs mapped 1-4094 Executing IEEE compatible Spanning Tree Protocol Root ID Priority 32768, Address 0001.e801.
Example (Guard) Dell#show spanning-tree msti 5 guard Interface Name Instance Sts Guard type -----------------------------------Te 1/1 5 INCON(Root) Rootguard Te 1/2 5 FWD Loopguard Te 1/3 5 EDS(Shut) Bpduguard spanning-tree Enable the multiple spanning tree protocol on the interface. S4810 Syntax spanning-tree To disable the multiple spanning tree protocol on the interface, use the no spanning-tree command. Parameters spanning-tree Enter the keywords spanning-tree to enable the MSTP on the interface.
spanning-tree msti Configure multiple spanning tree instance cost and priority for an interface. S4810 Syntax Parameters spanning-tree msti instance {cost cost | priority priority} msti instance Enter the keyword msti and the MST instance number. The range is from zero (0) to 63. cost cost (OPTIONAL) Enter the keyword cost then the port cost value. The range is from 1 to 200000.
tc-flush-standard Enable the MAC address flushing after receiving every topology change notification. S4810 Syntax tc-flush-standard To disable, use the no tc-flush-standard command. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
38 Multicast The multicast commands are supported by Dell Networking operating system (OS) on all S4810 platform. This chapter contains the following sections: • IPv4 Multicast Commands IPv4 Multicast Commands The following section contains the IPv4 multicast commands. clear ip mroute Clear learned multicast routes on the multicast forwarding table. To clear the protocol-independent multicast (PIM) tree information base, use the clear ip pim tib command.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series. E-Series legacy command Related Commands show ip pim tib — shows the PIM tree information base. ip mroute Assign a static mroute.
distance (OPTIONAL) Enter a number as the distance metric assigned to the mroute. The range is from 0 to 255. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.2(1.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series. 7.6.1.0 Introduced on the E-Series. This feature allows you to limit the number of multicast entries on the system. This number is the total of all the multicast entries on all line cards in the system. On each line card, the multicast module only installs the maximum number of entries, depending on the configured CAM profile. To store multicast routes, use the IN-L3-McastFib CAM partition.
Usage Information After you enable multicast, you can enable IGMP and PIM on an interface. In INTERFACE mode, enter the ip pim sparse-mode command to enable IGMP and PIM on the interface. Related Commands ip pim sparse-mode — enables IGMP and PIM on an interface. show ip mroute View the multicast routing table. Syntax Parameters show ip mroute [vrf vrf-name] [static | group-address [source-address] | count | snooping [vlan vlan-idIntroduced on the S6000-ON.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 9.2.(0.0) Added support for keyword vlt to the Z9000, S4810, and S4820T. 8.4.1.1 Support for the keyword snooping and the optional vlan vlan-id, groupaddress, and source-address parameters were added on E-Series ExaScale. 8.3.19.0 Introduced on the S4820T. 8.3.7.
Spanned outgoing interface list: Vlan 20 (S) Usage Information Example The following describes the show ip mroute command shown in the following example. Field Description (S, G) Displays the forwarding entry in the multicast route table. uptime Displays the amount of time the entry has been in the multicast forwarding table. Incoming interface Displays the reverse path forwarding (RPF) information towards the source for (S,G) entries and the RP for (*,G) entries.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.1 Introduced on the S4810. E-Series legacy command Usage Information Network administrators use static mroutes to control the reach-ability of the multicast sources.
39 Neighbor Discovery Protocol (NDP) The neighbor discovery protocol for IPv6 is defined in RFC 2461 as part of the Stateless Address Autoconfiguration protocol. It replaces the Address Resolution Protocol used with IPv4.
interface interface Command Modes Command History • EXEC • EXEC Privilege To remove all neighbor entries learned on a specific interface, enter the keyword interface then the interface type and slot/port or number information of the interface: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
interface interface hardware_address Enter the keyword interface then the interface type and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a port channel interface, enter the keywords port-channel then a number.
interface interface Defaults Enter the keyword interface then the interface type and slot/port or number information: • For a port channel interface, enter the keywords port-channel then a number. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port inform • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094.
• Router mode — When a policy with device role as router is applied on an interface, all the RA packets are validated based on the configuration information in the policy. Similarly, you can also apply this mode over any specific VLAN and the validation is performed only for that particular VLAN RA packets. To configure the IPv6 RA guard, use the following Dell Networking OS commands. debug ipv6 nd ra-guard Enable debugging for IPv6 RA guard snooping information.
Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, and Z9000 switches. • ipv6 nd raguard policy policy-name — Defines the RA guard policy name and enter the RA guard policy configuration mode. • ipv6 nd ra-guard enable — Allows you to configure the RA guard related commands. hop-limit Enable the verification of the advertised hop count limit. If this command is not configured, the verification process is bypassed.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, and Z9000 switches.
Related Commands ipv6 nd ra-guard enable — Allows you to configure the RA guard related commands. managed-config-flag Set the managed address configuration flag. Syntax managed-config-flag {on | off} To clear the flag, use the no managed-config-flag {on | off} command. Parameters on Enter the keyword on to set the managed-config-flag value as ON. off Enter the keyword off to set the managed-config flag value as OFF.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, and Z9000 switches. • ipv6 nd ra-guard enable — Allows you to configure the RA guard related commands.
Parameters on Enter the keyword on to set the other-config-flag value as ON. off Enter the keyword off to set the other-config flag value as OFF. Defaults none Command Modes POLICY LIST CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.
retrans-time Enable the verification of the configured retransmission timer value in the received RA packets. Syntax retrans—timer value To reset the advertised retransmission interval, use the no retrans-timervalue command. Parameters value Enter the advertised retransmission time interval in milliseconds. The range is from 100 to 4,294,967,295 milliseconds. Defaults none Command Modes POLICY LIST CONFIGURATION Command History This guide is platform-specific.
router-preference maximum Enable the verification of the advertised default router preference (DRP) value. The preference value is lower than or equal to the specified limit. If this command is not configured, the verification process is bypassed. Syntax router-preference maximum {high | low | medium} To reset the default router preference value, use the no router-preference maximum {high | low | medium} command. Parameters high Enter the keyword high to set the DRP value as high.
device-role router hop-limit maximum 251 mtu 1350 other-config-flag on reachable-time 540 retrans-timer 101 router-preference maximum medium trusted-port Dell(conf-ra_guard_policy_list)# Related Commands • ipv6 nd ra-guard enable — Allows you to configure the RA guard related commands. • ipv6 nd ra-guard policy — Defines the RA guard policy name and enter the RA guard policy list configuration mode. • device-role — Specifies the role of the device attached to the port.
Te 1/1 Dell# Related Commands • ipv6 nd ra-guard enable — Allows you to configure the RA guard related commands. • ipv6 nd ra-guard policy — Defines the RA guard policy name and enter the RA guard policy list configuration mode. • device-role — Specifies the role of the device attached to the port. • hop-limit — Enables the verification of the advertised hop count limit. • mtu — Sets the maximum transmission unit (MTU) value.
40 Object Tracking Object Tracking supports IPv4 and IPv6, and is available on the Dell Networking, C-Series, E-Series, S-Series, and S4810 platforms. Object tracking allows you to define objects of interest, monitor their state, and report to a client when a change in an object’s state occurs.
Example Version Description 8.4.1.0 Introduced. Dell#debug track all 04:35:04: %RPM0-P:RP2 %OTM-5-STATE: track 6 - Interface TenGigabitEthernet 1/2 line-protocol DOWN 04:35:04: %RPM0-P:RP2 %OTM-5-NOTIF: VRRP notification: resource ID 6 DOWN delay Configure the time delay used before communicating a change in the status of a tracked object to clients. Syntax delay {[up seconds] [down seconds]} To return to the default setting, use the no delay command.
description Enter a description of a tracked object. Syntax description {text} To remove the description, use the no description {text} command. Parameters text Enter a description to identify a tracked object (80 characters maximum). Defaults none Command Modes OBJECT TRACKING (conf_track_object-id) Command History Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced.
track 4 interface TenGigabitEthernet 1/2 ip routing track 5 ip route 192.168.0.0/24 reachability vrf red track resolution ip route isis 20 track resolution ip route ospf 10 Example (Object-id) Dell#show running-config track 300 track 300 ip route 10.0.0.0/8 metric threshold delay down 3 delay up 5 threshold metric up 100 Related Commands • show track – displays information about tracked objects, including configuration, current state, and clients which track the object.
Example Output Description Track object-id Displays the number of the tracked object. Interface type slot/ port, IP route ipaddress, IPv6 route ipv6-address Displays the interface type and slot/port number or address of the IPv4/IPv6 route that is being tracked. object is Up/Down Up/Down state of tracked object; for example, IPv4 interface, reachability or metric threshold of an IP route.
Related Commands • show running-config track – displays configuration information about tracked objects. • track interface ip routing – configures object tracking on the routing status of an IPv4 Layer 3 interface. • track interface line-protocol – configures object tracking on the line-protocol state of a Layer 2 interface. • track ip route metric threshold – configures object tracking on the threshold of an IPv4 route metric.
The tracking process uses a protocol-specific resolution value to convert the actual metric in the routing table to a scaled metric in the range 0 to 255. You can configure the resolution value used to scale route metrics for supported protocols with the track resolution ip route and track resolution ipv6 route commands. Related Commands • track ip route metric threshold – configures object tracking on the threshold of an IPv4 route metric.
track interface line-protocol Configure object tracking on the line-protocol state of a Layer 2 interface. Syntax track object-id interface interface line-protocol To return to the default setting, use the no track object-id command. Parameters object-id Enter the ID number of the tracked object. The range is 1 to 500.
ip-address/ prefixlen Enter an IPv4 address in dotted decimal format. The valid IPv4 prefix lengths are from /0 to /32. vrf vrf-name (Optional) E-Series only: You can configure a VPN routing and forwarding (VRF) instance to specify the virtual routing table to which the tracked route belongs. Defaults none Command Modes CONFIGURATION Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced.
Parameters object-id Enter the ID number of the tracked object. The range is 1 to 500. ip-address/ prefixlen Enter an IPv4 address in dotted decimal format. The valid IPv4 prefix lengths are from /0 to /32. vrf vrf-name (Optional) E-Series only: You can configure a VPN routing and forwarding (VRF) instance to specify the virtual routing table to which the tracked route belongs. Defaults none Command Modes CONFIGURATION Command History Usage Information Version Description 9.7(0.
Defaults none Command Modes CONFIGURATION Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced. Use this command to configure the protocol-specific resolution value that converts the actual metric of an IPv4 route in the routing table to a scaled metric in the range 0 to 255.
show track ipv6 route Display information about all tracked IPv6 routes, including configuration, current tracked state (UP or DOWN), and the clients which are tracking an object. Syntax show track ipv6 route [brief] Parameters Command Modes Command History Usage Information Example brief • EXEC • EXEC Privilege (OPTIONAL) Display a single line summary of information for tracked IPv6 routes. Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.12.0 Introduced on the S4810. 8.4.1.
Usage Command Example (Brief) The following describes the show track ipv6 route brief command shown in the Example below. Ouput Description ResID Number of the tracked object. Resource Type of tracked object. Parameter Detailed description of the tracked object. State Up or Down state of the tracked object. Last Change Time since the last change in the state of the tracked object.
Usage Information Related Commands Version Description 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced. Use this command to create an object that tracks the routing state of an IPv6 Layer 3 interface: • The status of the IPv6 interface is UP only if the Layer 2 status of the interface is UP and the interface has a valid IP address.
considers a lower value to have priority over a higher value. The resulting scaled value is compared against the configured threshold values to determine the state of a tracked route as follows: • If the scaled metric for a route entry is less than or equal to the UP threshold, the state of a route is UP. • If the scaled metric for a route is greater than or equal to the DOWN threshold or the route is not entered in the routing table, the state of a route is DOWN.
If the next-hop address in the ARP cache ages out for a route tracked for its reachability, an attempt is made to regenerate the ARP cache entry to if the next-hop address appears before considering the route DOWN. Related Commands • show track ipv6 route – displays information about tracked IPv6 routes, including configuration, current state, and clients which track the route. • track ipv6 route reachability – configures object tracking on the reachability of an IPv4 route.
Related Commands • threshold metric – configures the metric threshold used to determine the UP and/or DOWN state of a tracked route. • track ipv6 route metric threshold – configures object tracking on the threshold of an IPv6 route metric.
41 Open Shortest Path First (OSPFv2 and OSPFv3) Open Shortest Path First version 2 for IPv4 is supported on platform. OSPF is an Interior Gateway Protocol (IGP), which means that it distributes routing information between routers in a single Autonomous System (AS). OSPF is also a link-state protocol in which all routers contain forwarding tables derived from information about their links to their neighbors.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for the Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for the Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. area range Summarize routes matching an address/mask at an area border router (ABR).
Version Description pre- 6.1.1.1 Introduced on the E-Series. Usage Information Only the routes within an area are summarized, and that summary is advertised to other areas by the ABR. External routes are not summarized. Related Commands area stub — creates a stub area. router ospf — enters ROUTER OSPF mode to configure an OSPF instance. area stub Configure a stub area, which is an area not connected to other areas.
auto-cost Specify how the OSPF interface cost is calculated based on the reference bandwidth method. S4810 Syntax auto-cost [reference-bandwidth ref-bw] To return to the default bandwidth or to assign cost based on the interface type, use the no auto-cost [reference-bandwidth] command. Parameters ref-bw (OPTIONAL) Specify a reference bandwidth in megabits per second. The range is from 1 to 4294967. The default is 100 megabits per second. Defaults 100 megabits per second.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
neighbor router-id (OPTIONAL) Enter the keyword neighbor then the neighbor’s router-id in dotted decimal format (A.B.C.D.). Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.4(0.0) Added support for VRF. Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.
Example Field Description auk: If the ip ospf authentication-key command is configured, this field displays the key used. keyid: If the ip ospf message-digest-key command is configured, this field displays the MD5 key to: Displays the interface to which the packet is intended. dst: Displays the destination IP address. netmask: Displays the destination IP address mask.
metric metric-value (OPTIONAL) Enter the keyword metric then a number to configure a metric value for the route. The range is from 1 to 16777214. metric-type typevalue (OPTIONAL) Enter the keywords metric-type then an OSPF link state type of 1 or 2 for default routes. The values are: route-map mapname • 1 = Type 1 external route • 2 = Type 2 external route (OPTIONAL) Enter the keywords route-map then the name of an established route map. Defaults Disabled.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for the Multi-Process OSPF. 7.
Related Commands Version Description 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. show ip ospf asbr — displays the VLAN configuration. distance Define an administrative distance for particular routes to a specific IP address. S4810 Syntax distance weight [ip-address mask access-list-name] To delete the settings, use the no distance weight [ip-address mask access-list-name] command. Parameters weight Specify an administrative distance. The range is from 1 to 255.
distance ospf Configure an OSPF distance metric for different types of routes. S4810 Syntax distance ospf [external dist3] [inter-area dist2] [intra-area dist1] To delete these settings, use the no distance ospf command. Parameters Defaults external dist3 (OPTIONAL) Enter the keyword external then a number to specify a distance for external type 5 and 7 routes. The range is from 1 to 255. The default is 110.
distribute-list in Apply a filter to incoming routing updates from OSPF to the routing table. S4810 Syntax distribute-list prefix-list-name in [interface] To delete a filter, use the no distribute-list prefix-list-name in [interface] command. Parameters prefix-list-name Enter the name of a configured prefix list. interface (OPTIONAL) Enter one of the following keywords and slot/port or number information: • For Port Channel groups, enter the keywords port-channel then a number.
distribute-list out To restrict certain routes destined for the local routing table after the SPF calculation, apply a filter. S4810 Syntax distribute-list prefix-list-name out [bgp | connected | isis | rip | static] To remove a filter, use the no distribute-list prefix-list-name out [bgp | connected | isis | rip | static] command. Parameters prefix-list-name Enter the name of a configured prefix list. bgp (OPTIONAL) Enter the keyword bgp to specify that BGP routes are distributed.
Usage Information Version Description pre- 6.1.1.1 Introduced on the E-Series. The distribute-list out command applies to routes autonomous system boundary routers (ASBRs) redistributes into OSPF. It can be applied to external type 2 and external type 1 routes, but not to intra-area and inter-area routes. fast-convergence This command sets the minimum LSA origination and arrival times to zero (0), allowing more rapid route computation so that convergence takes less time.
graceful-restart grace-period Specifies the time duration, in seconds, that the router’s neighbors continue to advertise the router as fully adjacent regardless of the synchronization state during a graceful restart. NOTE: This command enables OSPFv2 graceful restart globally by setting the grace period (in seconds) that an OSPFv2 router’s neighbors continues to advertise the router as adjacent during a graceful restart.
Parameters ip-address Enter the OSPF router-id, in IP address format, of the restart router that will not act as a helper during graceful restart. Defaults Not configured. Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.12.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. graceful-restart role Specify the role for your OSPF router during graceful restart.
ip ospf auth-change-wait-time OSPF provides a grace period while OSPF changes its interface authentication type. During the grace period, OSPF sends out packets with new and old authentication scheme until the grace period expires. S4810 Syntax ip ospf auth-change-wait-time seconds To return to the default, use the no ip ospf auth-change-wait-time command. Parameters seconds Enter the seconds. The range is from 0 to 300. Defaults zero (0) seconds.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series.
Usage Information Version Description pre- 6.1.1.1 Introduced on the E-Series. If this command is not configured, cost is based on the auto-cost command. When you configure OSPF over multiple vendors, to ensure that all routers use the same cost, use the ip ospf cost command. Otherwise, OSPF routes improperly. Related Commands auto-cost — controls how the OSPF interface cost is calculated. ip ospf dead-interval Set the time interval since the last hello-packet was received from a router.
ip ospf hello-interval Specify the time interval between the hello packets sent on the interface. S4810 Syntax ip ospf hello-interval seconds To return to the default value, use the no ip ospf hello-interval command. Parameters seconds Enter the number of seconds for the interval. The range is from 1 to 65535. The default is 10 seconds. Defaults 10 seconds Command Modes INTERFACE Command History This guide is platform-specific.
Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 9.1(0.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. ip ospf network Set the network type for the interface. S4810 Syntax ip ospf network {broadcast | point-to-point} To return to the default, use the no ip ospf network command.
ip ospf priority To determine the designated router for the OSPF network, set the priority of the interface. S4810 Syntax ip ospf priority number To return to the default setting, use the no ip ospf priority command. Parameters number Enter a number as the priority. The range is from 0 to 255. The default is 1. Defaults 1 Command Modes INTERFACE Command History This guide is platform-specific.
This interval must be greater than the expected round-trip time for a packet to travel between two routers. Defaults 5 seconds Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. log-adjacency-changes To send a Syslog message about changes in the OSPF adjacency state, set Dell Networking OS. S4810 Syntax log-adjacency-changes To disable the Syslog messages, use the no log-adjacency-changes command.
To disable packet forwarding over multiple paths, use the no maximum-paths command. Parameters number Specify the number of paths. The range for OSPFv2 is from 1 to 64. The default for OSPFv2 is 4 paths. The range for OSPFv3 is from 1 to 64. The default for OSPFv3 is 8 paths. Defaults 4 Command Modes ROUTER OSPF for OSPFv2 ROUTER OSPFv3 for OSPFv3 Command History This guide is platform-specific.
Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
• For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a VLAN, enter the keyword vlan then a number from 1 to 4094. Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
• Remove the interface from the passive list. • The ABR status for the router is updated. • If passive-interface default is specified, then save no passive-interface interface into the running configuration. No passive-interface default • Clear everything and revert to the default behavior. • All previously marked passive interfaces are removed. • May update ABR status.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
Defaults none Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
• 2 = for OSPF External type 2 route-map mapname (OPTIONAL) Enter the keywords route-map then the name of the route map. tag tag-value (OPTIONAL) Enter the keyword tag to set the tag for routes redistributed into OSPF. The range is from 0 to 4294967295. Defaults Not configured. Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. Usage Information You can configure an arbitrary value in the IP address format for each router. However, each router ID must be unique.
Usage Information Version Description 9.1(0.0) Added support for OSPFv3 on the S4810 and Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.9.1.0 Added support for VRF. 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. You must have an IP address assigned to an interface to enter ROUTER OSPF mode and configure OSPF.
passive-interface 0 TenGigabitEthernet 1/1 Dell(conf-router_ospf)# show ip ospf Display information on the OSPF process configured on the switch. S4810 Syntax Parameters Command Modes Command History show ip ospf [process-id | vrf vrf name] process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process. vrf vrf name Show only the OSPF information tied to the VRF process.
Line Beginning with Description “Supports only...” Displays the number of Type of Service (TOS) rouse supported. “SPF schedule...” Displays the delay and hold time configured for this process ID. “Convergence Level” “Min LSA....” Displays the intervals set for LSA transmission and acceptance. “Number of...” Displays the number and type of areas configured for this process ID. Example Dell#show ip ospf 10 Routing Process ospf 10 with ID 1.1.1.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support of Multi-Process OSPF. 7.8.1.0 Added the process-id option, in support of Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series and E-Series.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
10.2.4.0 11.1.1.0 11.1.2.0 12.1.2.0 13.1.1.0 13.1.2.0 172.16.1.0 Dell> Related Commands 13.1.1.1 11.1.2.1 11.1.2.1 192.68.135.2 13.1.1.1 13.1.1.1 13.1.1.1 1184 718 718 1663 1192 1184 148 0x80000068 0x80000002 0x80000002 0x80000054 0x8000006b 0x8000006b 0x8000006d 0x45db 0x831e 0x7828 0xd8d6 0x2718 0x1c22 0x533b 0 0 0 0 0 0 0 show ip ospf database asbr-summary — displays only ASBR summary LSA information.
Usage Information Example Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. The following describes the show ip ospf database asbr-summary command shown in the following example. Field Description LS Age Displays the LSA’s age. Options Displays the optional capabilities available on router.
Length: 28 --More-Related Commands show ip ospf database — displays OSPF database information. show ip ospf database external Display information on the AS external (type 5) LSAs. S4810 Syntax Parameters show ip ospf [process-id | vrf vrf-name] database external [link-state-id] [adv-router ip-address] process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process.
Usage Information Example Version Description pre-6.1.1.1 Introduced on the E-Series. The following describes the show ip ospf process-id database external command shown in the following example. Field Description LS Age Displays the LSA’s age. Options Displays the optional capabilities available on router. The following options can be found in this item: • TOS-capability or No TOS-capability is displayed depending on whether the router can support Type of Service.
TOS: 0 Metrics: 25 Forward Address: 0.0.0.0 External Route Tag: 43 LS age: 1868 Options: (No TOS-capability, DC) LS type: Type-5 AS External Link State ID: 24.216.12.0 Advertising Router: 20.20.20.8 LS Seq Number: 0x80000005 Checksum: 0xa00e Length: 36 Network Mask: /24 Metrics Type: 2 TOS: 0 Metrics: 1 Forward Address: 0.0.0.0 External Route Tag: 701 Dell# Related Commands show ip ospf database — displays OSPF database information.
Usage Information Example Version Description 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.1 Introduced on the E-Series. The following describes the show ip ospf process-id database network command shown in the following example.
Attached Router: 20.20.20.8 Attached Router: 20.20.20.9 Attached Router: 20.20.20.7 Network (Area 0.0.0.1) LS age: 252 Options: (TOS-capability, No DC, E) LS type: Network Link State ID: 192.10.10.2 Advertising Router: 192.10.10.2 LS Seq Number: 0x80000007 Checksum: 0x4309 Length: 36 Network Mask: /24 Attached Router: 192.10.10.2 Attached Router: 20.20.20.1 Attached Router: 20.20.20.5 Dell# Related Commands show ip ospf database — displays OSPF database information.
Related Commands Version Description 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.1 Introduced on the E-Series. show ip ospf database — displays OSPF database information.
Usage Information Example Version Description 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.1 Introduced on the E-Series. The following describes the show ip ospf process-id database opaque-area command shown in the following example.
Unable to display opaque data LS age: 833 Options: (No TOS-capability, No DC, E) LS type: Type-10 Opaque Link Area Link State ID: 1.0.0.2 Advertising Router: 10.16.1.160 LS Seq Number: 0x80000002 Checksum: 0x19c2 --More-Related Commands show ip ospf database — displays OSPF database information. show ip ospf database opaque-as Display the opaque-as (type 11) LSA information.
Related Commands Version Description pre-6.1.1.1 Introduced on the E-Series. show ip ospf database — displays OSPF database information. show ip ospf database opaque-link Display the opaque-link (type 9) LSA information. S4810 Syntax Parameters show ip ospf [process-id | vrf vrf-name] database opaque-link [link-stateid] [adv-router ip-address] process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process.
Related Commands Version Description pre-6.1.1.1 Introduced on the E-Series. show ip ospf database — displays OSPF database information. show ip ospf database router Display the router (type 1) LSA information. S4810 Syntax show ip ospf [process-id | vrf vrf-name] database router [link-state-id] [adv-router ip-address] Parameters process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process.
Usage Information Example Version Description pre-6.1.1.1 Introduced on the E-Series. The following describes the show ip ospf process-id database router command shown in the following example. Item Description LS Age Displays the LSA age. Options Displays the optional capabilities available on router. The following options can be found in this item: • TOS-capability or No TOS-capability is displayed depending on whether the router can support Type of Service.
Link connected to: a Transit Network (Link ID) Designated Router address: 192.68.129.1 (Link Data) Router Interface address: 192.68.129.1 Number of TOS metric: 0 TOS 0 Metric: 1 Link connected to: a Transit Network (Link ID) Designated Router address: 192.68.130.1 (Link Data) Router Interface address: 192.68.130.1 Number of TOS metric: 0 TOS 0 Metric: 1 Link connected to: a Transit Network (Link ID) Designated Router address: 192.68.142.2 (Link Data) Router Interface address: 192.68.142.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Example Item Description Metric Displays the LSA metrics. Dell#show ip ospf 100 database summary OSPF Router with ID (1.1.1.10) (Process ID 100) Summary Network (Area 0.0.0.0) LS age: 1551 Options: (No TOS-capability, DC, E) LS type: Summary Network Link State ID: 192.68.16.0 Advertising Router: 192.168.17.1 LS Seq Number: 0x80000054 Checksum: 0xb5a2 Length: 28 Network Mask: /24 TOS: 0 Metric: 1 LS age: 9 Options: (No TOS-capability, No DC, E) LS type: Summary Network Link State ID: 192.68.32.
Command Modes Command History • EXEC • EXEC Privilege • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128.
Example Item Description Backup Designated... This line displays the ID of the Backup Designated Router and its interface address. Timer intervals... This line displays the interface’s timer settings for Hello interval, Dead interval, Transmit Delay (Wait), and Retransmit Interval. Hello due... This line displays the amount time until the next Hello packet is sent out this interface. Neighbor Count... This line displays the number of neighbors and adjacent neighbors.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000.. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
vrf vrf-name Defaults Enter the keyword vrf followed by the name of the VRF to show the OSPF RIB information corresponding to the OSPF processes that are tied to a specific VRF. none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
172.30.1.0 Dell# 2 13.0.0.3 Te 1/47 1 Intra-Area show ip ospf statistics Display OSPF statistics. S4810 Syntax Parameters show ip ospf [process-id | vrf vrf-name] statistics global | [interface name {neighbor router-id}] process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. The following describes the show ip ospf statistics process-id global command shown in the following example. Row Heading Description Total Displays the total number of packets the OSPF process receives/transmits.
Example Error Type Description MD5-Error MD5 error Cksum-Err Checksum Error Version Version mismatch AreaMismatch Area mismatch Conf-Issue The received hello packet has a different hello or dead interval than the configuration. No-Buffer Buffer allocation failure. Seq-no A sequence no errors occurred during the database exchange process. Socket Socket Read/Write operation error. Q-overflow Packets dropped due to queue overflow. Unknown-Pkt Received packet is not an OSPF packet.
Example (Statistics) Dell(conf-if-te-1/6)#do show ip ospf statistics Interface TenGigabitEthernet 1/6 Error packets (Receive statistics) Intf-Down 0 Non-Dr 0 Self-Org 0 Wrong-Len 0 Invld-Nbr 0 Nbr-State 0 Auth-Error 0 MD5-Error 0 Cksum-Err 0 Version 0 AreaMisMatch 0 Conf-Issue 0 SeqNo-Err 0 Unknown-Pkt 0 Bad-LsReq 0 RtidZero 0 Neighbor ID 4.4.4.
Example Version Description 8.3.8.0 Introduced on the S4810. Dell#show ip ospf 10 timers rate-limit List of LSAs in rate limit Queue LSA id: 1.1.1.0 Type: 3 Adv Rtid: 3.3.3.3 Expiry time: 00:00:09.111 LSA id: 3.3.3.3 Type: 1 Adv Rtid: 3.3.3.3 Expiry time: 00:00:23.96 Dell# show ip ospf topology Display routers in directly connected areas.
Example Dell#show ip ospf 1 topology Router ID 3.3.3.3 1.1.1.1 Dell# Flags Cost E/B/-/ 1 E/-/-/ 1 Nexthop 20.0.0.3 10.0.0.1 Interface Area Gi 13/1 0 Gi 7/1 1 summary-address To advertise one external route, set the OSPF ASBR. S4810 Syntax summary-address ip-address mask [not-advertise] [tag tag-value] To disable summary address, use the no summary-address ip-address mask command. Parameters ip-address Specify the IP address in dotted decimal format of the address to summarize.
routes with prefix 1.1.0.0, you can configure the summary-address 1.1.0.0 255.255.0.0 not-advertise to filter out all the routes fall in range 1.1.0.0/16. Related Commands area range — summarizes routes within an area. timers spf Set the time interval between when the switch receives a topology change and starts a shortest path first (SPF) calculation. S4810 Syntax timers spf delay holdtime To return to the default, use the no timers spf command.
Dell(conf-router_ospf-1)#show config ! router ospf 1 timers spf 2 5 Dell(conf-router_ospf-1)# Dell(conf-router_ospf-1)#end Dell# Dell# timers throttle lsa all Configure LSA transmit intervals. S4810 Syntax timers throttle lsa all {start-interval | hold-interval | max-interval} To return to the default, use the no timers throttle lsa command. Parameters Defaults start-interval Set the minimum interval between initial sending and resending the same LSA. The range is from 0 to 600,000 milliseconds.
timers throttle lsa arrival Configure the LSA acceptance intervals. S4810 Syntax timers throttle lsa arrival arrival-time To return to the default, use the no timers throttle lsa command. Parameters arrival-time Set the interval between receiving the same LSA repeatedly, to allow sufficient time for the system to accept the LSA. The range is from 0 to 600,000 milliseconds. Defaults 1000 msec Command Modes ROUTER OSPF Command History This guide is platform-specific.
The range is from 0 to 4294967295. ipsec spi number Security Policy index (SPI) value that identifies an IPsec security policy. The range is from 256 to 4294967295. MD5 | SHA1 Authentication type: Message Digest 5 (MD5) or Secure Hash Algorithm 1 (SHA-1). key-encryptiontype (OPTIONAL) Specifies if the key is encrypted. The values are 0 (key is not encrypted) or 7 (key is encrypted). key Text string used in authentication.
show crypto ipsec policy – displays the configuration of IPsec authentication policies. area encryption Configure an IPsec encryption policy for OSPFv3 packets in an OSPFv3 area. S4810 Syntax Parameters area area-id encryption ipsec spi number esp encryption-algorithm [keyencryption-type] key authentication-algorithm [key-encryption-type] key area area-id Area for which OSPFv3 traffic is to be encrypted. For area-id, enter a number. The range is from 0 to 4294967295.
null Causes an encryption policy configured for the area to not be inherited on the interface. Defaults Not configured. Command Modes ROUTER OSPFv3 Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.1.(0.0) Introduced on the S4810 and Z9000. 8.4.2.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF. 9.2(1.0) Introduced on the Z9500. 9.1.(0.0) Introduced on the S4810 and Z9000. 8.3.19.0 Introduced on the S4820T. 7.8.1.0 Added support for C-Series. 7.
Example Lines Beginning With or Including Description OSPFv3... Debugging is on for all OSPFv3 packets and all interfaces. 05:21:01 Displays the time stamp. Sending Ver:3 Sending OSPF3 version..
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Command Fields Version Description 9.2(1.0) Introduced on the Z9500. 9.1.(0.0) Introduced on the S4810 and Z9000. 8.3.19.0 Introduced on the S4820T. 7.8.1.0 Added support for C-Series. 7.4.1.
default-information originate Configure the Dell Networking OS to generate a default external route into an OSPFv3 routing domain. S4810 Syntax default-information originate [always] [metric metric-value] [metric-type type-value] [route-map map-name] To return to the default values, use the no default-information originate command. Parameters always (OPTIONAL) Enter the keyword always to specify that default route information must always be advertised.
Parameters seconds Time duration, in seconds, that specifies the duration of the restart process before OSPFv3 terminates the process. The range is from 40 to 1800 seconds. Defaults OSPFv3 graceful restart is disabled and functions in a helper-only role. Command Modes ROUTER OSPFv3 Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.1.(0.0) Introduced on the S4810 and Z9000. 8.4.2.2 Introduced on the E-Series TeraScale. 8.3.19.0 Introduced on the S4820T. OSPFv3 graceful restart supports planned-only and/or unplanned-only restarts. The default is support for both planned and unplanned restarts.
Parameters null Causes an authentication policy configured for the area to not be inherited on the interface. ipsec spi number Security Policy index (SPI) value that identifies an IPsec security policy. The range is from 256 to 4294967295. MD5 | SHA1 Authentication type: Message Digest 5 (MD5) or Secure Hash Algorithm 1 (SHA-1). key-encryptiontype (OPTIONAL) Specifies if the key is encrypted. Valid values: 0 (key is not encrypted) or 7 (key is encrypted). key Text string used in authentication.
ipv6 ospf bfd all-neighbors Establish BFD sessions with all OSPFv3 neighbors on a single interface or use non-default BFD session parameters. S4810 Syntax ipv6 ospf bfd all-neighbors [disable | [interval interval min_rx min_rx multiplier value role {active | passive}]] To disable all BFD sessions on an OSPFv3 interface implicitly, use the no ipv6 ospf bfd allneighbors disable command in interface mode.. Parameters disable (OPTIONAL) Enter the keyword disable to disable BFD on this interface.
ipv6 ospf cost Explicitly specify the cost of sending a packet on an interface. S4810 Syntax Parameters ipv6 ospf interface-cost interface-cost Enter a unsigned integer value expressed as the link-state metric. The range is from 1 to 65535. Defaults Default cost based on the bandwidth. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Defaults 40 seconds (Ethernet). Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.1.(0.0) Introduced on the S4810 and Z9000. 7.8.1.0 Added support for C-Series. 7.4.1.0 Introduced on the E-Series. 8.3.19.0 Introduced on the S4820T.
authenticationalgorithm Specifies the authentication algorithm to use for encryption. Valid values are MD5 or SHA1. key-encryptiontype (OPTIONAL) Specifies if the authentication key is encrypted. Valid values: 0 (key is not encrypted) or 7 (key is encrypted). key Text string used in authentication. For MD5 authentication, the key must be 32 hex digits (non-encrypted) or 64 hex digits (encrypted). For SHA-1 authentication, the key must be 40 hex digits (non-encrypted) or 80 hex digits (encrypted).
ipv6 ospf graceful-restart helper-reject Configure an OSPFv3 interface to not act upon the Grace LSAs that it receives from a restarting OSPFv3 neighbor. S4810 Syntax ipv6 ospf graceful-restart helper-reject To disable the helper-reject role, enter no ipv6 ospf graceful-restart helper-reject. Defaults The helper-reject role is not configured. Command Modes INTERFACE Command History This guide is platform-specific.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.1.(0.0) Introduced on the S4810 and Z9000. 7.8.1.0 Added support for the C-Series. 7.4.1.0 Introduced on the E-Series. 8.3.19.0 Introduced on the S4820T. Usage Information The time interval between hello packets must be the same for routers in a network. Related Commands ipv6 ospf dead-interval – specifies the time interval between hello packets was received from a router.
To exit OSPF for IPv6, use the no ipv6 router ospf process-id command. Parameters process-id Enter the process identification number. The range is from 1 to 65535. vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to install IPv6 routes in that VRF. Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Version Description pre-6.1.1.1 Introduced on the E-Series. passive-interface Disable (suppress) sending routing updates on an interface. S4810 Syntax passive—interface interface To enable sending routing updates on an interface, use the no passive-interface interface command. Parameters interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
redistribute Redistribute into OSPFv3. S4810 Syntax redistribute {bgp as number}{connected | static}[metric metric-value | metric-type type-value] [route-map map-name] [tag tag-value] To disable redistribution, use the no redistribute {connected | static} command. Parameters bgp as number Enter the keyword bgp then the autonomous system number. The range is from 1 to 65535. connected Enter the keyword connected to redistribute routes from physically connected interfaces.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.1.(0.0) Introduced support for OSPFv3 on the S4810 and Z9000. 8.3.19.0 Introduced on the S4820T. 7.8.1.0 Added support for the C-Series. 7.4.1.0 Introduced on the E-Series.
If this command is used on an OSPFv3 process that is already active (has neighbors), all the neighbor adjacencies are brought down immediately and new sessions are initiated with the new router ID. Related Commands clear ipv6 ospf process – resets an OSPFv3 router process. show crypto ipsec policy Display the configuration of IPsec authentication and encryption policies.
Crypto IPSec client security policy data Policy name : OSPFv3-0-501 Policy refcount : 1 Inbound ESP SPI : 501 (0x1F5) Outbound ESP SPI : 501 (0x1F5) Inbound ESP Auth Key : bbdd96e6eb4828e2e27bc3f9ff541e43faa759c9ef5706ba8ed8bb5efe91e97eb7c0 c30808825fb5 Outbound ESP Auth Key : bbdd96e6eb4828e2e27bc3f9ff541e43faa759c9ef5706ba8ed8bb5efe91e97eb7c0 c30808825fb5 Inbound ESP Cipher Key : bbdd96e6eb4828e2e27bc3f9ff541e43faa759c9ef5706ba10345a1039ba8f8a Outbound ESP Cipher Key : bbdd96e6eb4828e2e27bc3f9ff541e43faa7
Parameters interface interface (OPTIONAL) Displays information about the SAs used on a specified OSPFv3 interface, where interface is one of the following values: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a port channel interface, enter the keywords port-channel then a number.
outbound esp sas Interface: TenGigabitEthernet 1/2 Link Local address: fe80::201:e8ff:fe40:4d11 IPSecv6 policy name: OSPFv3-1-600 inbound ah sas outbound ah sas inbound esp sas spi : 600 (0x258) transform : esp-des esp-sha1-hmac in use settings : {Transport, } replay detection support : N STATUS : ACTIVE outbound esp sas spi : 600 (0x258) transform : esp-des esp-sha1-hmac in use settings : {Transport, } replay detection support : N STATUS : ACTIVE show crypto ipsec sa ipv6 Command Fields Field Description
Parameters process-number Enter the OSPF process number. vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to display neighbors corresponding to that VRF. NOTE: If you do not specify this option, neighbors corresponding to the default VRF are displayed. database-summary (OPTIONAL) Enter the keywords database-summary to view a summary of database LSA information.
Process 1 database summary Type Count/Status Oper Status 1 Admin Status 1 Area Bdr Rtr Status 1 AS Bdr Rtr Status 1 AS Scope LSA Count 0 AS Scope LSA Cksum sum 0 Originate New LSAS 50 Rx New LSAS 22 Ext LSA Count 0 Rte Max Eq Cost Paths 10 GR grace-period 180 GR mode planned and unplanned Area 0 database summary Type Count/Status Brd Rtr Count 1 AS Bdr Rtr Count 1 LSA count 6 Rtr LSA Count 2 Net LSA Count 1 Inter Area Pfx LSA Count 1 Inter Area Rtr LSA Count 0 Group Mem LSA Count 0 Type-7 LSA count 0 Intra
interface Defaults none Command Modes EXEC Command History Usage Information (OPTIONAL) Enter one of the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a port channel interface, enter the keywords port-channel then a number.
vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to display OSPF neighbors corresponding to that VRF. NOTE: If you do not specify this option, neighbors corresponding to the default VRF are displayed. interface Defaults none Command Modes EXEC (OPTIONAL) Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
holdtime Defaults Enter a number as the hold time. The range is from 0 to 4294967295. The default is 10 seconds. • delay = 5 seconds • holdtime = 10 seconds Command Modes ROUTER OSPFv3 for OSPFv3 Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.
42 Policy-based Routing (PBR) Policy-based routing (PBR) allows you to apply routing policies to specific interfaces. To enable PBR, create a redirect list and apply it to the interface. After the redirect list is applied to the interface, all traffic passing through the interface is subject to the rules defined in the redirect list. PBR is supported by the Dell Networking Operating System (OS).
ip redirect-group Apply a redirect list (policy-based routing) on an interface. You can apply multiple redirect lists to an interface by entering this command multiple times. S4810 Syntax ip redirect-group redirect-list-name To remove a redirect list from an interface, use the no ip redirect-group name command. Parameters redirect-list-name Enter the name of a configured redirect list. Defaults none Command Modes INTERFACE (conf-if-vl-) Command History Usage Information Version Description 9.
Parameters redirect-list-name Defaults None Command Modes CONFIGURATION Command History Enter the name of a redirect list. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000. 8.4.2.1 Introduced on the C-Series and S-Series. 8.4.2.0 Introduced on the E-Series Tera Scale. 7.7.1.0 Introduced on the E-Series ExaScale. permit Configure a permit rule.
operator Defaults none Command Modes REDIRECT-LIST Command History • ack = acknowledgement • fin = finish (no more data from the user) • psh = push function • rst = reset the connection • syn = synchronize sequence number • urg = urgent field (OPTIONAL) For TCP and UDP parameters only.
ip-address Enter the IP address of the forwarding router. slot/port Enter the keyword slot / port followed by the slot/port information. tunnel Enter the keyword tunnel to configure the tunnel setting. tunnel-id Enter the keyword tunnel-id to redirect the traffic. track Enter the keyword track to enable the tracking. track Enter the keyword track to track object-id. ip-protocol-number Enter a number from 0 to 255 for the protocol identified in the IP protocol header.
Version Description 9.7(0.0) Added support for the track-id on the S4810, S4820T, S6000, and Z9000. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000. 8.4.2.1 Introduced on the C-Series and S-Series. 8.4.2.0 Introduced on the E-Series Tera Scale. 7.7.1.0 Introduced on the E-Series ExaScale. seq Configure a filter with an assigned sequence number for the redirect list.
host ip-address Enter the keyword host then the IP address to specify a host IP address. destination Enter the IP address of the network or host to which the packets are sent.
show cam pbr Display the PBR CAM content. S4810 Syntax show cam pbr {[interface interface] | stack—unit slot-number port-set number]} [summ Parameters interface interface Enter the keyword interface then the name of the interface. stack–unit number Enter the keyword stack-unit then the slot number. port-set number Enter the keywords port-set then the port-pipe number. summary Enter the keyword summary to view only the total number of CAM entries.
Parameters Command Modes Command History Example redirect-list-name • EXEC • EXEC Privilege Enter the name of a configured Redirect list. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000. Dell#show ip redirect-list explicit_tunnel IP redirect-list explicit_tunnel: Defined as: seq 5 redirect tunnel 1 track 1 tcp 155.55.2.0/24 222.22.2.
43 PIM-Sparse Mode (PIM-SM) The protocol-independent multicast (PIM) commands are supported by the Dell Networking operating software on the platform. IPv4 PIM-Sparse Mode Commands The following describes the IPv4 PIM-sparse mode (PIM-SM) commands. clear ip pim rp-mapping The bootstrap router (BSR) feature uses this command to remove all or particular rendezvous point (RP) advertisement.
Usage Information This command re-applies the RP mapping logic for all the groups learnt by the node. Any stale information corresponding to the existing mapping configuration is updated. As a result, the existing BSR cache and the *,G's are deleted only if these entries are stale. clear ip pim tib Clear PIM tree information from the PIM database.
debug ip pim View IP PIM debugging messages. S4810 Syntax debug ip pim [vrf vrf-name] [bsr | events | group | packet [in | out] | register | state | timer [assert | hello | joinprune | register]] To disable PIM debugging, use the no debug ip pim [vrf vrf-name] command or use the undebug allto disable all debugging command. Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to view IP PIM debugging messages corresponding to that VRF.
Version Description 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.12.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the S-Series. ip pim bsr-border Define the border of PIM domain by filtering inbound and outbound PIM-BSR messages per interface. Syntax ip pim bsr-border To return to the default value, use the no ip pim bsr-border command.
Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to configure the PIM router on a VRF. interface Enter the following keywords and slot/port or number information: • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
Defaults 1 Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Version Description 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the C-Series for the port-channels and the S-Series. 7.7.1.0 Introduced on the E-Series. Example Dell(conf)# ip access-list extended iptv-channels Dell(config-ext-nacl)# permit ip 10.1.2.3/24 225.1.1.
ip pim neighbor-filter To prevent a router from participating in protocol independent multicast (PIM), configure this feature. S4810 Syntax ip pim [vrf vrf-name] neighbor-filter {access-list} To remove the restriction, use the no ip pim [vrf vrf-name] neighbor-filter {accesslist} command. Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to prevent that VRF from participating in PIM. NOTE: Applies to specific VRF if input is provided, else applies to default VRF.
Parameters seconds Enter a number as the number of seconds between router query messages. The range is from 0 to 65535. The default is 30 seconds. Defaults 30 seconds Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON.
Usage Information Version Description 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series and S-Series. 7.6.1.0 Introduced The access name is an extended IP access list that denies PIM register packets to RP at the source DR based on the multicast and group addresses. Do not enter this command before creating the access-list.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the S-Series. pre- 6.1.1.1 Introduced on the E-Series. First-hop routers use this address by to send register packets on behalf of source multicast hosts. The RP addresses are stored in the order in which they are entered.
Usage Information Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the S-Series. pre- 6.1.1.1 Introduced on the E-Series. Priority is stored at BSR router when receiving a Candidate-RP-Advertisement.
ip pim sparse-mode sg-expiry-timer Enable expiry timers globally for all sources. S4810 Syntax ip pim [vrf vrf-name] sparse-mode sg-expiry-timer seconds To disable configured timers and return to default mode, use the no ip pim [vrf vrf-name] sparse-mode sg-expiry-timer command. Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to enable expiry timer for all sources on that VRF. NOTE: Applies to specific VRF if input is provided, else applies to Default VRF.
ip pim ssm-range Specify the SSM group range using an access list. Syntax Parameters ip pim [vrf vrf-name] ssm-range {access_list_name} vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to specify the SSM group range for that VRF. NOTE: Applies to specific VRF if input is provided, else applies to Default VRF. access_list_name Enter the name of the access list.
When you remove the SSM ACL, PIM SSM is supported for the default SSM range only. ip pim spt-threshold To switch to the shortest path tree when the traffic reaches the specified threshold value, configure the PIM router. S4810 Syntax ip pim [vrf vrf-name] spt-threshold [infinity] To return to the default value, use the no ip pim [vrf vrf-name] spt-threshold [infinity] command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced on the E-Series ExaScale.
Example Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the S-Series. Dell#show ip pim bsr-router PIMv2 Bootstrap information This system is the Bootstrap Router (v2) BSR address: 7.7.7.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the S-Series. The following describes the show ip pim interface command shown in the following example. Field Description Address Lists the IP addresses of the interfaces participating in PIM. Interface List the interface type, with either slot/port information or ID (VLAN or Port Channel), of the interfaces participating in PIM.
• Command History EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.
show ip pim rp View all multicast groups-to-RP mappings. S4810 Syntax Parameters Command Modes Command History show ip pim [vrf vrf-name] rp [mapping | group-address] vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to configure this setting on that VRF. mapping (OPTIONAL) Enter the keyword mapping to display the multicast groups-to-RP mapping and information on how RP is learnt.
Example (Address) Dell#show ip pim rp 229.1.2.1 Group RP 229.1.2.1 165.87.20.4 show ip pim snooping interface Display information on VLAN interfaces with PIM-SM snooping enabled. Syntax show ip pim snooping interface [vlan vlan-id] Parameters Command Modes Command History vlan vlan-id • EXEC • EXEC Privilege (OPTIONAL) Enter a VLAN ID to display information about a specified VLAN configured for PIM-SM snooping. The valid VLAN IDs range is from 1 to 4094. This guide is platform-specific.
show ip pim snooping neighbor Display information on PIM neighbors learned through PIM-SM snooping. Syntax Parameters Command Modes Command History show ip pim snooping neighbor [vlan vlan-id] vlan vlan-id • EXEC • EXEC Privilege (OPTIONAL) Enter a VLAN ID to display information about PIM neighbors that PIM-SM snooping discovered on a specified VLAN. The valid VLAN IDs range is from 1 to 4094. This guide is platform-specific.
Neighbor Interface Uptime/Expires Ver Address 165.87.32.2 Vl 2 [Te 1/13 ] 00:04:03/00:01:42 v2 165.87.32.10 Vl 2 [Te 1/11 ] 00:00:46/00:01:29 v2 165.87.32.12 Vl 2 [Te 2/20 ] 00:00:51/00:01:24 v2 DR Prio 1 0 0 show ip pim snooping tib Display information from the tree information base (TIB) PIM-SM snooping discovered about multicast group members and states.
Field Example Description • R = the forwarding entry is pointing toward the RP • F = Dell Networking OS is registering this entry for a multicast source • T = packets were received via Shortest Tree Path • J = first packet from the last hop router is received and the entry is ready to switch to SPT • K=acknowledge pending state Incoming interface Displays the reverse path forwarding (RPF) interface towards the RP/ source.
Command Modes Command History Exmaple • EXEC • EXEC Privilege Version Description 9.7(0.0) Introduced on the S6000-ON. Added support for VRF on S6000, S4810, S4820T, Z9000, Z9500, and S6000–ON. 9.5(0.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.1 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 7.5.
Example Version Description 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.4.1.1 Support for the display of PIM-SM snooping status was added on E-Series ExaScale. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the S-Series.
NOTE: Applies to specific VRF if input is provided, else applies to Default VRF. Command Modes Command History group-address (OPTIONAL) Enter the group address in dotted decimal format (A.B.C.D). source-address (OPTIONAL) Enter the source address in dotted decimal format (A.B.C.D). • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Field Description • Example K = acknowledge pending state Incoming interface Displays the reverse path forwarding (RPF) interface towards the RP/ source. RPF neighbor Displays the next hop from this interface towards the RP/source.
Example 1180 Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.4.1.0 Introduced on the E-Series ExaScale.
44 Port Monitoring The port monitoring feature allows you to monitor network traffic by forwarding a copy of each incoming or outgoing packet from one port to another port. Important Points to Remember • Port monitoring is supported on physical ports and logical interfaces, such as port channels and virtual local area networks (VLANs). • The monitoring (destination, “MG”) and monitored (source, “MD”) ports must be on the same switch.
Related Commands Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.7.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-7.7.1.0 Introduced on the E-Series. monitor session — enables a monitoring session. monitor session Create a session for monitoring traffic with port monitoring.
Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Added the drop parameter. 9.7(0.0) Introduced on the S6000-ON. Introduced the set ip dscp and set ip ttl parameters. 9.5(0.1) Introduced on the Z9500. 9.4(0.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.8(0.0) Introduced on the S4810, S4820T, S5000, S6000, S6000-ON, Z9500. monitor session — enables a monitoring session. show monitor session — displays the monitor session.
show monitor session Display information about monitoring sessions. Syntax show monitor session {session-ID} To display monitoring information for all sessions, use the show monitor session command. Parameters Defaults Command Modes Command History session-ID (OPTIONAL) Enter a session identification number. The range is from 0 to 65535. none • EXEC • EXEC Privilege This guide is platform-specific.
show running-config monitor session Display the running configuration of all monitor sessions or a specific session. Syntax show running-config monitor session {session-ID} To display the running configuration for all monitor sessions, use the show running-config monitor session command. Parameters Defaults session-ID (OPTIONAL) Enter a session identification number. The range from 0 to 65535. none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific.
source (port monitoring) Configure a port monitor source. Syntax source {interface | range | any} destination interface direction {rx | tx | both} To disable a monitor source, use the no source interface destination interface direction {rx | tx | both} command. Parameters source interface Enter one of the following keywords and slot/port information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example 1188 Version Description 9.8(0.0) Added the any parameter. 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.4.0.0 Added support for Source and destination. 9.0.2.0 Introduced on the S6000. 8.3.19.
45 Private VLAN (PVLAN) The private VLAN (PVLAN) feature of the Dell Networking operating software is supported on the S4810 platforms. Private VLANs extend the Dell Networking OS security suite by providing Layer 2 isolation between ports within the same private VLAN. A private VLAN partitions a traditional VLAN into subdomains identified by a primary and secondary VLAN pair. The Dell Networking OS private VLAN implementation is based on RFC 3069. For more information, refer to the following commands.
– A trunk port in a PVLAN is always tagged. – A trunk port in Tagged mode carries primary or secondary VLAN traffic. The tag on the packet helps identify the VLAN to which the packet belongs. – A trunk port can also belong to a regular VLAN (non-private VLAN). ip local-proxy-arp Enable/disable Layer 3 communication between secondary VLANs in a private VLAN.
private-vlan mode Set PVLAN mode of the selected VLAN to community, isolated, or primary. S4810 Syntax [no] private-vlan mode {community | isolated | primary} To remove the PVLAN configuration, use the no private-vlan mode {community | isolated | primary} command syntax. Parameters community Enter the keyword community to set the VLAN as a community VLAN. isolated Enter the keyword isolated to configure the VLAN as an isolated VLAN.
private-vlan mapping secondary-vlan Map secondary VLANs to the selected primary VLAN. S4810 Syntax [no] private-vlan mapping secondary-vlan vlan-list To remove specific secondary VLANs from the configuration, use the no private-vlan mapping secondary-vlan vlan-list command syntax. Parameters vlan-list Enter the list of secondary VLANs to associate with the selected primary VLAN. The list can be in comma-delimited or hyphenated-range format, following the convention for the range input.
switchport mode private-vlan Set PVLAN mode of the selected port. S4810 Syntax [no] switchport mode private-vlan {host | promiscuous | trunk} To remove PVLAN mode from the selected port, use the no switchport mode private-vlan command. Parameters host Enter the keyword host to configure the selected port or port channel as an isolated interface in a PVLAN. promiscuous Enter the keyword promiscuous to configure the selected port or port channel as an promiscuous interface.
Related Commands private-vlan mode — sets the mode of the selected VLAN to community, isolated, or primary. private-vlan mapping secondary-vlan — sets the mode of the selected VLAN to primary and then associates the secondary VLANs to it.
46 Per-VLAN Spanning Tree Plus (PVST+) The Dell Networking operating software implementation of per-VLAN spanning tree plus (PVST+) is based on the IEEE 802.1w standard spanning tree protocol. Dell Networking OS supports PVST+ on the S4810 platform. NOTE: For easier command line entry, the plus (+) sign is not used at the command line. description Enter a description of the PVST+. S4810 Syntax description {description} To remove the description, use the no description {description} command.
disable Disable PVST+ globally. S4810 Syntax disable To enable PVST+, use the no disable command. Defaults Disabled. Command Modes CONFIGURATION (conf-pvst) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced. Dell(conf-pvst)#do show spanning-tree pvst vlan 5 brief VLAN 5 Executing IEEE compatible Spanning Tree Protocol Root ID Priority 32773, Address 0001.e832.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 8.3.1.0 Introduced.
• guard Defaults Command Modes Command History For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. (OPTIONAL) Enter the keyword guard to display the type of guard enabled on a PVST interface and the current port state. none • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Configured hello time 2, max age 20, forward delay 15 Interface Designated Name PortID Prio Cost Sts Cost Bridge ID PortID ---------------------------------------------------------Te 1/0 128.130 128 20000 FWD 20000 4096 0001.e801.6aa8 128.426 Te 1/1 128.131 128 20000 BLK 20000 4096 0001.e801.6aa8 128.427 Te 1/16 128.146 128 20000 FWD 20000 16384 0001.e805.e306 128.146 Te 1/17 128.147 128 20000 FWD 20000 16384 0001.e805.e306 128.
Edge port:no (default) port guard :none (default) Link type: point-to-point (auto) bpdu filter:disable (default) Bpdu guard :disable (default) Bpdus sent 152, received 27562 Interface Designated Name PortID Prio Cost Sts Cost Bridge ID PortID ----------------------------------------------------------Te 1/1 128.1223 128 20000 EDS 0 32768 0001.e800.a12b 128.
Enter the keyword bpduguard to disable the port when it receives a BPDU. shutdown-onviolation (OPTIONAL) Enter the keywords shutdown-on-violation to hardware disable an interface when a BPDU is received and the port is disabled. err-disable Enter the keywords err-disable to enable the port to be put into the errordisable state (EDS) if an error condition occurs. vlan vlan-range Enter the keyword vlan then the VLAN numbers. The range is from 1 to 4094.
Usage Information Version Description 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added the optional Bridge Port Data Unit (BPDU) guard. 6.2.1.1 Introduced. The BPDU guard option prevents the port from participating in an active STP topology in case a BPDU appears on a port unintentionally, or is misconfigured, or is subject to a DOS attack. This option places the port into the Error Disable state if a BPDU appears, and a message is logged so that the administrator can take corrective action.
spanning-tree pvst err-disable Place ports in an Err-Disabled state if they receive a PVST+ BPDU when they are members an untagged VLAN. S4810 Syntax spanning-tree pvst err-disable cause invalid-pvst-bpdu Defaults Enabled; ports are placed in the Err-Disabled state if they receive a PVST+ BPDU when they are members of an untagged VLAN. Command Modes INTERFACE Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series.
Related Commands Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced. vlan forward-delay — changes the time interval before Dell Networking OS transitions to the Forwarding state. vlan hello-time — change the time interval between BPDUs. vlan max-age — changes the time interval before PVST+ refreshes.
Related Commands Version Description 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced. vlan bridge-priority — sets the bridge-priority value. vlan hello-time — changes the time interval between BPDUs. vlan max-age — changes the time interval before PVST+ refreshes. show spanning-tree pvst — displays the PVST+ configuration. vlan hello-time Set the time interval between generation of PVST+ 7 BPDUs.
Related Commands Version Description 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced. vlan bridge-priority — sets the bridge-priority value. vlan forward-delay — changes the time interval before Dell Networking OS transitions to the forwarding state. vlan max-age — changes the time interval before PVST+ refreshes. show spanning-tree pvst — displays the PVST+ configuration.
Related Commands Version Description 6.2.1.1 Introduced. vlan bridge-priority — sets the bridge-priority value. vlan forward-delay — changes the time interval before Dell Networking OS transitions to the forwarding state. vlan hello-time — changes the time interval between BPDUs. show spanning-tree pvst — displays the PVST+ configuration.
47 Quality of Service (QoS) The Dell Networking operating software commands for quality of service (QoS) include traffic conditioning and congestion control. QoS commands are not universally supported on all Dell Networking Products. S4810 platform. This chapter contains the following sections: • Global Configuration Commands • Per-Port QoS Commands • Policy-Based QoS Commands Global Configuration Commands There is only one global configuration QoS command.
Version Description 8.3.1.0 Introduced. Per-Port QoS Commands Per-port QoS (port-based QoS) allows you to define the QoS configuration on a per-physical-port basis. dot1p-priority Assign a value to the IEEE 802.1p bits on the traffic this interface receives. Syntax dot1p-priority priority-value To delete the IEEE 802.1p configuration on the interface, use the no dot1p-priority command. Parameters priority-value Enter a value from 0 to 7.
Usage Information The dot1p-priority command changes the priority of incoming traffic on the interface. The system places traffic marked with a priority in the correct queue and processes that traffic according to its queue. When you set the priority for a port channel, the physical interfaces assigned to the port channel are configured with the same value. You cannot assign the dot1p-priority command to individual interfaces in a port channel.
On one interface, you can configure the rate police command for a VLAN or you can configure the rate police command for an interface. rate shape Shape the traffic output on the selected interface. S4810 Syntax Parameters rate shape [kbps] rate [burst-KB] kbps Enter the keyword kbps to specify the rate limit in Kilobits per second (Kbps). On S-Series, make the value a multiple of 64. The range is from 0 to 40000000. The default granularity is Megabits per second (Mbps).
Parameters Defaults queue Enter a value from 0 to 7. For each dot1p Priority, the default CoS queue value is: • Dot1p Priority : 0 1 2 3 4 5 6 7 • Queue : 2 0 1 3 4 5 6 7 Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
Command Modes Command History • INTERFACE • CONFIGURATION This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. After you configure a unicast queue as strict-priority, that particular queue, on the entire chassis, is treated as a strict-priority queue. Traffic for a strict priority is scheduled before any other queues are serviced. For example, if you send 100% line rate traffic over the SP queue, it starves all other queues on the ports on which this traffic is flowing.
Usage Information The unit of bandwidth percentage is 1%. If the sum of the bandwidth percentages given to all eight classes exceeds 100%, the bandwidth percentage automatically scales down to 100%. Related Commands qos-policy-output — creates a QoS output policy. class-map Create/access a class map. Class maps differentiate traffic so that you can apply separate quality-of-service policies to each class.
Usage Information Packets arriving at the input interface are checked against the match criteria and configured using this command to determine if the packet belongs to that class. This command accesses CLASS-MAP mode, where the configuration commands include thematch ip and match mac options. Related Commands ip access-list extended — configures an extended IP ACL. ip access-list standard — configures a standard IP ACL.
Related Commands Version Description 9.0.2.0 Introduced on the S6000. 8.3.18.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. show qos statistics — displays the QoS statistics. description Add a description to the selected policy map or QoS policy. S4810 Syntax description {description} To remove the description, use the no description {description} command.
match ip access-group Configure match criteria for a class map, based on the access control list (ACL). NOTE: IPv6 class-maps and IP-any class-maps do not match. This condition is true for IPv6 and IP-any class-maps on both ACLs as well as VLANs. S4810 Syntax match ip access-group access-group-name [set-ip-dscp value | set-color value] To remove ACL match criteria from a class map, use the no match ip access-group accessgroup-name [set-ip-dscp value | set-color value] command.
match ip dscp Use a differentiated services code point (DSCP) value as a match criteria. S4810 Syntax match {ip | ipv6 | ip-any} dscp dscp-list [set-ip-dscp value] To remove a DSCP value as a match criteria, use the no match {ip | ipv6 | ip-any} dscp dscp-list [[multicast] set-ip-dscp value] command. Parameters ip Enter the keyword ip to support IPv4 traffic. ipv6 Enter the keyword ipv6 to support IPv6 traffic. ip-any Enter the keyword ip-any to support IPv4 and IPv6 traffic.
match ip precedence Use IP precedence values as a match criteria. S4810 Syntax match {ip | ipv6 | ip-any} precedence ip-precedence-list [set-ip-dscp value] To remove IP precedence as a match criteria, use the no match {ip | ipv6 | ip-any} precedence ip-precedence-list [[multicast] set-ip-dscp value] command. Parameters ip Enter the keyword ip to support IPv4 traffic. ipv6 Enter the keyword ipv6 to support IPv6 traffic. ip-any Enter the keyword ip-any to support IPv4 and IPv6 traffic.
NOTE: Only one of the IP precedence values must be a successful match criterion, not all of the specified IP precedence values must match. Related Commands class-map — identifies the class map. match ip vlan Uses a VLAN as the match criterion for an L3 class map. S4810 Syntax match ip vlan vlan-id To remove VLAN as the match criterion, use the no match ip vlan vlan-id command. Parameters vlan vlan-id Enter the keyword vlan and then the ID of the VLAN. The range is from 1 to 4094.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5.(0.0) Introduced on the Z9500. 9.4.(0.0) Introduced on the S-Series and Z-Series. To access this command, enter the class-map command.
match mac dot1p Configure a match criterion for a class map based on a dot1p value. S4810 Syntax Parameters match mac dot1p {dot1p-list} dot1p-list Enter a dot1p value. The range is from 0 to 7. Defaults none Command Modes CLASS-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced. Usage Information To access this command, enter the class-map command. You can match against only one VLAN ID. Related Commands class-map — identifies the class map. policy-aggregate Allow an aggregate method of configuring per-port QoS via policy maps. An aggregate QoS policy is part of the policy map (output) applied on an interface.
policy-map-input Create an input policy map. S4810 Syntax policy-map-input policy-map-name cpu-qos | [layer2] To remove an input policy map, use the no policy-map-input policy-map-name cpu-qos | [layer2] command. Parameters policy-map-name Enter the name of the policy map in character format (32 characters maximum). cpu-qos Enter the cpu-qos keyword to assign this ACL to control plane traffic only. layer2 (OPTIONAL) Enter the keyword layer2 to specify a Layer 2 Class Map. The default is Layer 3.
Parameters policy-map-name Enter the name for the policy map in character format (32 characters maximum). Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Use this command to specify the name of the input QoS policy. Once input policy is specified, rate-police can be defined.
Usage Information Use this command to specify the name of the output QoS policy. Once output policy is specified, rateshape, scheduler strict, bandwidth-percentage, and WRED can be defined. This command enables the qospolicy-output configuration mode—(conf-qos-policy-out). Related Commands bandwidth-percentage — assigns percentage of bandwidth to the class/queue. wred — assigns yellow or green drop precedence.
Usage Information This command does not uniquely identify a queue, but rather identifies only a set of queues. The WRED curve is applied to all eight egress Multicast queues. Important Points to Remember — Multicast-Bandwidth Option • A unique multicast weighted fair queuing (WFQ) setting can be applied only on a per port-pipe basis. The minimum percentage of the multicast bandwidth assigned to any of the ports in the port-pipe takes effect for the entire port-pipe.
Usage Information Version Description 8.3.8.0 Introduced on the S4810. 7.4.1.0 and 6.5.3.0 Introduced on the E-Series. This command does not uniquely identify a queue, but rather identifies only a set of queues. The WRED Curve is applied to all eight ingress Multicast queues. NOTE: The multicast-bandwidth option is not supported on queue ingress.
Related Commands rate police — specifies traffic policing on the selected interface. qos-policy-input — creates a QoS output policy. rate-shape Shape traffic output as part of the designated policy. S4810 Syntax Parameters rate-shape [kbps] rate [burst-KB] kbps Enter the keyword kbps to specify the rate limit in Kilobits per second (Kbps). Make the following value a multiple of 64. The range is from 0 to 40000000. The default granularity is Megabits per second (Mbps).
To remove the input policy map from the interface, use the no service-policy input policymap-name [layer2] command. Parameters policy-map-name Enter the name for the policy map in character format (32 characters maximum). You can identify an existing policy map or name one that does not yet exist. layer2 (OPTIONAL) Enter the keyword layer2 to specify a Layer 2 Class Map. The default is Layer 3. Defaults Layer 3 Command Modes INTERFACE Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Usage Information There are eight queues per interface on the S6000 and four queues on the S-Series. This command assigns a class map or QoS policy to different queues. Related Commands class-map — identifies the class map. service-policy input — applies an input policy map to the selected interface.
show qos class-map View the current class map information. S4810 Syntax Parameters Defaults Command Modes Command History show qos class-map [class-name] class-name (Optional) Enter the name of a configured class map. none • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. Usage Information trust dot1p, do1p-priority, service-class dynamic dot1; all these features work over the mapping in this command output. Related Commands service-class dot1p-mapping — Identifies the class map. show qos policy-map View the QoS policy map information.
Example (IPv4) Version Description 8.3.7.0 Introduced on the S4810.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
Example Version Description 8.3.7.0 Introduced on the S4810. Dell#show qos policy-map-output Policy-map-output PolicyMapOutput Aggregate Qos-policy-name AggPolicyOut Queue# Qos-policy-name 0 qosPolicyOutput Dell# show qos qos-policy-input View the input QoS policy details. S4810 Syntax Parameters Defaults Command Modes Command History show qos qos-policy-input [qos-policy-name] qos-policy-name Enter the QoS policy name. none • EXEC • EXEC Privilege This guide is platform-specific.
show qos qos-policy-output View the output QoS policy details. S4810 Syntax show qos qos-policy-output [qos-policy-name] Parameters Defaults qos-policy-name Enter the QoS policy name. none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
• wred-profile interface interface Defaults Command Modes Command History For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. Enter the keywords wred-profile and optionally one of the following keywords and slot/port or number information: • For a 40–Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
Defaults none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. This feature allows you to determine if the CAM has enough space available before applying the configuration on an interface. An input policy map with both Trust and Class-map configuration, the Class-map rules are ignored and only the Trust rule is programmed in the CAM.
13 Dell# … … L2ACL 1 400 200 Allowed (2) threshold Specify the minimum and maximum threshold values for the configured WRED profiles. S4810 Syntax threshold min number max number max-drop-probability To remove the threshold values, use the no threshold min number max number command. Parameters min number Enter the keyword min then the minimum threshold number for the WRED profile. The range is from 1 to 9360.
Related Commands wred-profile — creates a WRED profile. trust Specify dynamic classification (DSCP) or dot1p to trust. S4810 Syntax Parameters trust {diffserv [fallback]| dot1p [fallback]} diffserv Enter the keyword diffserv to specify trust of DSCP markings. dot1p Enter the keyword dot1p to specify trust dot1p configuration. fallback Enter the keyword fallback to classify packets according to their DSCP or dot1p value as a secondary option in case no match occurs against the configured class maps.
DSCP/CP hex Range (XXX) DSCP Definition Traditional IP Precedence S6000 Internal Queue ID S-Series Internal Queue ID DSCP/CP Decimal 011XXX AF3 Flash 3 1 16–31 010XXX AF2 Immediate 2 1 16–31 001XXX AF1 Priority 1 0 0–15 000XXX BE (Best Effort) Best Effort 0 0 0–15 wred Designate the WRED profile to yellow or green traffic. S4810 Syntax wred {yellow | green} profile-name To remove the WRED drop precedence, use the no wred {yellow | green} [profile-name] command.
Related Commands wred-profile — creates a WRED profile and name that profile. trust — defines the dynamic classification to trust DSCP. wred ecn To indicate network congestion, rather than dropping packets, use explicit congestion notification (ECN). S4810 Syntax wred ecn To stop marking packets, use the no wred ecn command. Defaults none Command Modes CONFIGURATION (conf-qos-policy-out) Command History This guide is platform-specific.
wred-profile Create a WRED profile and name the profile. S4810 Syntax wred-profile wred-profile-name To remove an existing WRED profile, use the no wred-profile command. Parameters wred-profile-name Enter your WRED profile name in character format (32 character maximum). Or use one of the pre-defined WRED profile names. You can configure up to 26 WRED profiles plus the five pre-defined profiles, for a total of 31 WRED profiles.
DSCP Color Map Commands The DSCP color map allows you to set the number of specific DSCP values to yellow or red. Traffic marked as yellow delivers traffic to the egress queue which will either transmit the packet if it has available bandwidth or drop the packet due to no ability to send. Traffic marked as red (high drop precedence) is dropped. dscp Sets the number of specific DSCP values for a color map profile to yellow or red.
Example Dell(conf-dscp-color-map)# dscp yellow 9,10,11,13,15,16 Related Commands qos dscp-color-map — configures the DSCP color map qos dscp-color-policy— configures a DSCP color policy qos dscp-color-map Configure the DSCP color map. Syntax qos dscp-color-map map-name To remove a color map, use the no qos dscp-color-map map-name command. Parameters map-name Enter the name of the DSCP color map. The map name can have a maximum of 32 characters.
To remove a color policy map profile, use the no dscp-color-policy color-map-profile-name command. Parameters color-map-profilename Enter the color map profile name. The name can have a maximum of 32 characters. Defaults None Command Modes CONFIG-INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5.0.0 Introduced on the Z9000, S6000, S4820T, S4810, and MXL. Display summary information about a color policy on one or more interfaces. Dell# show qos dscp-color-policy summary Interface TE 1/10 TE 1/11 dscp-color-map mapONE mapTWO Display summary information about a color policy on a specific interface.
Dscp-color-map mapONE yellow 4,7 red 20,30 Dscp-color-map mapTWO yellow 16,55 Display a specific DSCP color map.
48 Routing Information Protocol (RIP) Routing information protocol (RIP) is a distance vector routing protocol. The Dell Networking operating software supports both RIP version 1 (RIPv1) and RIP version 2 (RIPv2) on the S4810 platform. The Dell Networking OS implementation of RIP is based on IETF RFCs 2453 and RFC 1058. For more information about configuring RIP, refer to the Dell Networking OS Configuration Guide.
clear ip rip Update all the RIP routes in the Dell Networking OS routing table. S4810 Syntax clear ip rip Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.
database (OPTIONAL) Enter the keyword database to display messages when there is a change to the RIP database. events (OPTIONAL) Enter the keyword events to debug only RIP protocol changes. trigger (OPTIONAL) Enter the keyword trigger to debug only RIP trigger extensions. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series.
Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. Usage Information This command ensures that route information being redistributed is converted to the same metric value. Related Commands redistribute — allows you to redistribute routes learned by other methods. description Enter a description of the RIP routing protocol.
distance Assign a weight (for prioritization) to all routes in the RIP routing table or to a specific route. Lower weights (“administrative distance”) are preferred. S4810 Syntax distance weight [ip-address mask [prefix-name]] To return to the default values, use the no distance weight [ip-address mask] command. Parameters weight Enter a number from 1 to 255 for the weight (for prioritization). The default is 120. ip-address (OPTIONAL) Enter the IP address, in dotted decimal format (A.B.C.
To delete the filter, use the no distribute-list prefix-list-name in command. Parameters prefix-list-name Enter the name of a configured prefix list. interface (OPTIONAL) Identifies the interface type slot/port as one of the following: • For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
To delete the filter, use the no distribute-list prefix-list-name out command. Parameters prefix-list-name Enter the name of a configured prefix list. interface (OPTIONAL) Identifies the interface type slot/port as one of the following: • For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
ip poison-reverse Set the prefix of the RIP routing updates to the RIP infinity value. S4810 Syntax ip poison-reverse To disable poison reverse, use the no ip poison-reverse command. Defaults Disabled. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. Usage Information To enable the interface to send both version of RIP packets, use the ip rip send version 1 2 command.
Related Commands Version Description pre- 6.2.1.1 Introduced on the E-Series. ip poison-reverse — sets the prefix for RIP routing updates. maximum-paths Set RIP to forward packets over multiple paths. S4810 Syntax maximum-paths number To return to the default values, use the no maximum-paths commands. Parameters number Enter the number of paths. The range is from 1 to 16. The default is 4 paths. Defaults 4 Command Modes ROUTER RIP Command History This guide is platform-specific.
To delete a neighbor setting, use the no neighbor ip-address command. Parameters ip-address Enter the IP address, in dotted decimal format, of a router with which to exchange information. Defaults Not configured. Command Modes ROUTER RIP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series.
Defaults Not configured. Command Modes ROUTER RIP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. This command is intended for low-speed interfaces. passive-interface Suppress routing updates on a specified interface.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. Usage Information Although the passive interface does not send or receive routing updates, the network on that interface still includes in RIP updates sent using other interfaces.
Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. Usage Information To redistribute the default route (0.0.0.0/0), configure the default-information originate command. Related Commands default-information originate — generates a default route for RIP traffic. redistribute isis Redistribute routing information from an IS-IS instance.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. pre- 6.2.1.1 Introduced on the E-Series. redistribute ospf Redistribute routing information from an OSPF process. S4810 Syntax redistribute ospf process-id [match external {1 | 2} | match internal | metric metric-value] [route-map map-name] To disable redistribution, use the no redistribute ospf process-id [match external {1 | 2} | match internal | metric metric-value] [route-map map-name] command.
Version Description 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. router rip To configure and enable RIP, enter ROUTER RIP mode. S4810 Syntax router rip To disable RIP, use the no router rip command. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
show config Display the changes you made to the RIP configuration. The default values are not shown. S4810 Syntax show config Command Modes ROUTER RIP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
show running-config rip Display the current RIP configuration. S4810 Syntax show running-config rip Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.
Defaults invalid Enter the number of seconds to specify the time interval before routing updates are declared invalid or expired. The invalid value should be at least three times the update timer value. The range is from zero (0) to 4294967295. The default is 180 seconds. holddown Enter the number of seconds to specify a time interval during which the route is marked as unreachable but still sending RIP packets. The holddown value should be at least three times the update timer value.
To return to the default version setting, use the no version command. Parameters 1 Enter the keyword 1 to specify RIP version 1. 2 Enter the keyword 2 to specify RIP version 2. Defaults The Dell Networking OS sends RIPv1 and receives RIPv1 and RIPv2. Command Modes ROUTER RIP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
49 Remote Monitoring (RMON) The Dell Networking operating software remote monitoring (RMON) is implemented on the S4810 platform. Dell Networking OS RMON is based on IEEE standards, providing both 32-bit and 64-bit monitoring and long-term statistics collection.
interval Time, in seconds, the alarm monitors the MIB variables; this is the alarmSampleType in the RMON alarm table. The range is from 5 to 3600 seconds. delta Enter the keyword delta to test the change between MIB variables. This is the alarmSampleType in the RMON alarm table. absolute Enter the keyword absolute to test each MIB variable directly. This is the alarmSampleType in the RMON alarm table.
rmon collection history Enable the RMON MIB history group of statistics collection on an interface. S4810 Syntax rmon collection history {controlEntry integer} [owner name] [buckets number] [interval seconds] To remove a specified RMON history group of statistics collection, use the no rmon collection history {controlEntry integer} command. Parameters controlEntry integer Enter the keyword controlEntry to specify the RMON group of statistics using a value.
rmon collection statistics Enable RMON MIB statistics collection on an interface. S4810 Syntax rmon collection statistics {controlEntry integer} [owner name] To remove RMON MIB statistics collection on an interface, use the no rmon collection statistics {controlEntry integer} command. Parameters controlEntry integer Enter the keyword controlEntry to specify the RMON group of statistics using a value. Then enter an integer value from 1 to 65535 that identifies the RMON Statistic Table.
Parameters number Assign an event number in integer format. The range is from 1 to 65535. You must ensure that the value you enter is unique in the RMON event table. log (OPTIONAL) Enter the keyword log to generate an RMON event log. This option sets the eventType to either log or log-and-snmptrap in the RMON event table. The default is None. trap community (OPTIONAL) Enter the keyword trap followed by the SNMP community string to generate SNMP traps for an RMON event entry.
variable The MIB object to monitor. The variable must be in the SNMP OID format; for example, 1.3.6.1.2.1.1.3 The object type must be a 64-bit integer. interval Time, in seconds, the alarm monitors the MIB variables; this is the alarmSampleType in the RMON alarm table. The range is from 5 to 3600 seconds. delta Enter the keyword delta to test the change between MIB variables. This is the alarmSampleType in the RMON alarm table. absolute Enter the keyword absolute to test each MIB variable directly.
show rmon Display the RMON running status including the memory usage. S4810 Syntax show rmon Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
show rmon events Display the contents of the RMON event table. S4810 Syntax Parameters show rmon events [index] [brief] index (OPTIONAL) Enter the table index number to display just that entry. brief (OPTIONAL) Enter the keyword brief to display the RMON event table in an easy-to-read format. Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
event owner: event status: OK RMON event entry 114 description: event type: LOG and SNMP TRAP. event community: public event last time sent: none event owner: event status: OK Example (Brief) Dell#show rmon event brief index description -----------------------------1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 17 17 18 18 19 19 20 20 21 21 22 22 Dell# show rmon hc-alarm Display the contents of RMON High-Capacity alarm table.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. Example (Index) Dell#show rmon hc-alarm 1 RMON high-capacity alarm entry 2 object: 1.3.6.1.2.1.2.2.1.4.2099844 sample interval: 10 sample type: delta value.
Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
brief (OPTIONAL) Enter the keyword brief to display the RMON log table in an easyto-read format. Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
brief (OPTIONAL) Enter the keyword brief to display the RMON Ethernet statistics table in an easy-to-read format. Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example (Index) 1294 Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
HC 512-1023 bytes packets: 0 HC 1024-1518 bytes packets overflow: 0 HC 1024-1518 bytes packets: 0 Dell# Example (Brief) Dell#show rmon statistics br index ifIndex interface ---------------------------------------6001 100974631 TenGigabitEthernet 2/2 6002 100974631 TenGigabitEthernet 2/2 6003 101236775 TenGigabitEthernet 2/1 6004 101236775 TenGigabitEthernet 2/1 9001 134529054 TenGigabitEthernet 3/2 9002 134529054 TenGigabitEthernet 3/2 9003 134791198 TenGigabitEthernet 3/1 9004 134791198 TenGigabitEthernet
50 Rapid Spanning Tree Protocol (RSTP) The Dell Networking operating software implementation of rapid spanning tree protocol (RSTP) is based on the IEEE 802.1w standard spanning-tree protocol. The RSTP algorithm configures connectivity throughout a bridged local area network (LAN) that is comprised of LANs interconnected by bridges. Dell Networking OS supports RSTP. bridge-priority Set the bridge priority for RSTP.
debug spanning-tree rstp Enable debugging of RSTP and view information on the protocol. Syntax debug spanning-tree rstp [all | bpdu interface {in | out} | events] To disable debugging, use the no debug spanning-tree rstp command. Parameters all (OPTIONAL) Enter the keyword all to debug all spanning tree operations. bpdu interface {in | out} (OPTIONAL) Enter the keyword bpdu to debug the bridge protocol data units.
description Enter a description of the rapid spanning tree. Syntax description {description} To remove the description, use the no description {description} command. Parameters description Enter a description to identify the rapid spanning tree (80 characters maximum). Defaults none Command Modes SPANNING TREE (The prompt is “config-rstp”.) Command History This guide is platform-specific.
Related Commands Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. protocol spanning-tree rstp — enters SPANNING TREE mode on the switch. forward-delay Configure the amount of time the interface waits in the Listening State and the Learning State before transitioning to the Forwarding State.
hello-time Set the time interval between the generation of the RSTP bridge protocol data units (BPDUs). Syntax hello-time [milli-second] seconds To return to the default value, use the no hello-time command. Parameters seconds Enter a number as the time interval between transmission of BPDUs. The range is from 1 to 10 seconds. The default is 2 seconds. milli-second Enter the keywords milli-second to configure a hello time on the order of milliseconds.
max-age To maintain configuration information before refreshing that information, set the time interval for the RSTP bridge. Syntax max-age seconds To return to the default values, use the no max-age command. Parameters max-age Enter a number of seconds the Dell Networking OS waits before refreshing configuration information. The range is from 6 to 40 seconds. The default is 20 seconds.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. Usage Information RSTP is not enabled when you enter RSTP mode.
no disable bridge-priority 16384 show spanning-tree rstp Display the RSTP configuration. Syntax Parameters Command Modes Command History Usage Information Example (Brief) show spanning-tree rstp [brief] [guard] brief (OPTIONAL) Enter the keyword brief to view a synopsis of the RSTP configuration information. guard (OPTIONAL) Enter the keyword guard to display the type of guard enabled on an RSTP interface and the current port state. • EXEC • EXEC Privilege Version Description 9.7(0.
Root ID Priority 8192, Address 0001.e805.e306 Root Bridge hello time 4, max age 20, forward delay 15 Bridge ID Priority 16384, Address 0001.e801.6aa8 Configured hello time 2, max age 20, forward delay 15 Interface Designated Name PortID Prio Cost Sts Cost Bridge ID PortID ---------- ------- --- ------- -------------------- -------Te 4/2 128.418 128 20000 FWD 20000 16384 0001.e801.6aa8 128.418 Te 4/1 128.419 128 20000 FWD 20000 16384 0001.e801.6aa8 128.419 Te 4/8 128.426 128 20000 FWD 20000 8192 0001.e805.
spanning-tree rstp Configure an RSTP interface with one of these settings: port cost, edge port with optional bridge port data unit (BPDU) guard, port priority, loop guard, or root guard. Syntax Parameters spanning-tree rstp {cost port-cost | edge-port [bpduguard [shutdown-onviolation]] | priority priority | {loopguard | rootguard}} cost port-cost Enter the keyword cost then the port cost value. The range is from 1 to 200000.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.4.2.1 Added support for the optional guard keyword on the C-Series, S-Series, and ESeries TeraScale. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced the hardware shutdown-on-violation options. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added the optional bridge port data unit (BPDU) guard. 6.2.1.1 Introduced on the E-Series.
tc-flush-standard Enable the MAC address flushing after receiving every topology change notification. Syntax tc-flush-standard To disable, use the no tc-flush-standard command. Defaults Disabled Command Modes CONFIGURATION (conf-rstp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
51 Software-Defined Networking (SDN) Dell Networking operating software supports Software-Defined Networking (SDN). For more information, refer to the SDN Deployment Guide.
52 Security The commands in this chapter are available on Dell Networking OS. This chapter contains various types of security commands offered in the Dell Networking operating software. The commands are listed in the following sections: • AAA Accounting Commands • Authorization and Privilege Commands • Authentication and Password Commands • RADIUS Commands • TACACS+ Commands • Port Authentication (802.
commands {level | role role-name Enter the keyword command then a privilege level for accounting of commands executed at that privilege level or enter the keyword role then the role name for accounting of commands executed by a user with that user role. name | default Enter one of the following: • For name, enter a user-defined name of a list of accounting methods. • For default, the default accounting methods used.
Dell(conf)# aaa accounting command role secaadmin default start-stop tacacs + Related Commands enable password — changes the password for the enable command. login authentication — enables AAA login authentication on the terminal lines. password — creates a password. tacacs-server host — specifies a TACACS+ server host. accounting Apply an accounting method list to terminal lines.
aaa accounting suppress Prevent the generation of accounting records of users with the user name value of NULL. Syntax aaa accounting suppress null-username To permit accounting records to users with user name value of NULL, use the no aaa accounting suppress null-username command. Defaults Accounting records are recorded for all users. Command Modes CONFIGURATION Command History This guide is platform-specific.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4.(0.0) Introduced on the S-Series and Z-Series. You can use this command to configure the group of Radius servers used for Authentication, Authorization, and Accounting purposes. If the RADIUS group is not configured for Authentication, Authorization, and Accounting, then globally configured Radius servers are used for the purposes.
Task ID 16, EXEC Accounting record, 00:00:04 Elapsed, service=shell Dell# Related Commands aaa accounting — enables AAA Accounting and creates a record for monitoring the accounting function. Authorization and Privilege Commands To set command line authorization and privilege levels, use the following commands. authorization Apply an authorization method list to terminal lines.
Related Commands aaa authorization commands — sets the parameters that restrict (or permit) a user’s access to EXEC and CONFIGURATION level commands aaa authorization exec — sets the parameters that restrict (or permit) a user’s access to EXEC level commands. aaa authorization commands Set parameters that restrict (or permit) a user’s access to EXEC and CONFIGURATION level commands.
aaa authorization config-commands Set parameters that restrict (or permit) a user’s access to EXEC level commands. Syntax aaa authorization config-commands Disable authorization checking for CONFIGURATION level commands using the no aaa authorization config-commands command. Defaults Enabled when you configure aaa authorization commands command. Command Modes CONFIGURATION Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series.
Version Description pre-6.1.1.0 Introduced on the E-Series. Obscure Password Commands To enable the obscure password, use the following commands. service obscure-passwords Enable the obscuring of passwords and keys. Syntax service obscure-passwords Enable the obscuring of passwords and keys, including RADIUS, TACACS+ keys, router authentication strings, VRRP authentication, use the service obscure-passwords command. Defaults Disabled.
Authentication and Password Commands To manage access to the system, use the following the commands. aaa authentication enable Configure AAA Authentication method lists for user access to EXEC privilege mode (the “Enable” access). Syntax aaa authentication enable {default | method-list-name} method [... method2] To return to the default setting, use the no aaa authentication enable {default | methodlist-name} method [... method2] command.
Usage Information Version Description 6.2.1.0 Introduced on the E-Series. By default, the Enable password is used. If you configure aaa authentication enable default, Dell Networking OS uses the methods defined for Enable access instead. Methods configured with the aaa authentication enable command are evaluated in the order they are configured. If authentication fails using the primary method, Dell Networking OS employs the second method (or third method, if necessary) automatically.
... method4 (OPTIONAL) Enter up to four additional methods. In the event of a “no response” from the first method, the system applies the next configured method (up to four configured methods). Defaults Not configured (that is, no authentication is performed). Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
tacacs-server host — specifies a TACACS+ server host. access-class Restrict incoming connections to a particular IP address in a defined IP access control list (ACL). Syntax access-class access-list-name To delete a setting, use the no access-class command. Parameters access-list-name Enter the name of an established IP Standard ACL. Defaults Not configured. Command Modes LINE Command History This guide is platform-specific.
encryption-type (OPTIONAL) Enter the number 7 or 0 as the encryption type. Enter a 7 then a text string as the hidden password. The text string must be a password that was already encrypted by a Dell Networking router. Use this parameter only with a password that you copied from the show running-config file of another Dell Networking router. password Enter a text string, up to 32 characters long, as the clear text password. Defaults No password is configured. level = 15.
enable restricted Allows Dell Networking technical support to access restricted commands. Syntax enable restricted [encryption-type] password To disallow access to restricted commands, use the no enable restricted command. Parameters encryption-type (OPTIONAL) Enter the number 7 as the encryption type. Enter 7 followed a text string as the hidden password. The text string must be a password that was already encrypted by a Dell Networking router.
encryption-type (OPTIONAL) Enter the number 5 or 0 as the encryption type. Enter a 5 then a text string as the hidden password. The text string must be a password that was already encrypted by a Dell Networking router. Use this parameter only with a password that you copied from the show running-config file of another Dell Networking router. password Enter a text string, up to 32 characters long, as the clear text password. Defaults No password is configured. level = 15.
login authentication To configure authentication for console or remote access, apply an authentication method list. Syntax login authentication {method-list-name | default} To use the local user/password database for login authentication, use the no login authentication command. Parameters method-list-name Enter the keywords method-list-name to specify that method list, created in the aaa authentication login command, to be applied to the designated terminal line.
password Specify a password for users on terminal lines. Syntax password [encryption-type] password To delete a password, use the no password password command. Parameters encryption-type password (OPTIONAL) Enter either zero (0) or 7 as the encryption type for the password entered. The options are • 0 is the default and means the password is not encrypted and stored as clear text. • 7 means that the password is encrypted and hidden. Enter a text string up to 32 characters long.
username — establishes an authentication system based on user names. password-attributes Configure the password attributes (strong password).
Related Commands Version Description 9.5(0.0) Introduced lockout-period option on the Z9000, S6000, S4820T, S4810, and MXL. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.3.1.0 Introduced on the E-Series. password — specifies a password for users on terminal lines.
To keep unauthorized people from viewing passwords in the switch configuration file, use the service password-encryption command. This command encrypts the clear-text passwords created for user name passwords, authentication key passwords, the privileged command password, and console and virtual terminal line access passwords. To view passwords, use the show running-config command. show privilege View your access level.
Parameters all (OPTIONAL) Enter the keyword all to view all terminal lines in the switch. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example Description 9.7(0.0) Introduced on the S6000–ON. 9.5(0.
timeout login response Specify how long the software waits for the login input (for example, the user name and password) before timing out. Syntax timeout login response seconds To return to the default values, use the no timeout login response command. Parameters seconds Enter a number of seconds the software waits before logging you out. The range is: • VTY: the range is from 1 to 30 seconds, the default is 30 seconds.
Parameters name Enter a text string for the name of the user up to 63 characters. access-class access-list-name Enter the keywords access-class then the name of a configured access control list (either an IP access control list or MAC access control list). nopassword Enter the keyword nopassword to specify that the user should not enter a password. password Enter the keyword password then the encryption-type or the password. secret Enter the keyword secret then the encryption-type or the password.
Version Description pre-6.1.1.0 Introduced on the E-Series. Usage Information To view the defined user names, use the show running-config user command. Related Commands password — specifies a password for users on terminal lines. show running-config — views the current configuration. RADIUS Commands The following RADIUS commands are supported by Dell Networking OS. debug radius View RADIUS transactions to assist with troubleshooting.
Parameters interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
radius-server key — sets an authentication key for RADIUS communications. radius-server retransmit — sets the number of times the RADIUS server attempts to send information. radius-server timeout — sets the time interval before the RADIUS server times out. radius-server host Configure a RADIUS server host.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.4.1.0 Added support for IPv6. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Authentication key length increased to 42 characters. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.0 Introduced on the E-Series.
Syntax radius-server vrf vrf-name [source-interface interface] To delete the association between a RADIUS server group and a VRF and source interface, use the no radius-server vrf vrf-name [source-interface interface] command. Parameters vrf vrf-name Enter the keyword vrf and then the name of the VRF to associate a RADIUS server group with that VRF.
Dell(conf-radius-group)#radius-server vrf default radius-server key Configure a key for all RADIUS communications between the switch and the RADIUS host server. Syntax radius-server key [encryption-type] key To delete a password, use the no radius-server key command. Parameters encryption-type key (OPTIONAL) Enter either zero (0) or 7 as the encryption type for the key entered. The options are: • 0 is the default and means the key is not encrypted and stored as clear text.
radius-server retransmit Configure the number of times the switch attempts to connect with the configured RADIUS host server before declaring the RADIUS host server unreachable. Syntax radius-server retransmit retries To configure zero retransmit attempts, use the no radius-server retransmit command. To return to the default setting, use the radius-server retransmit 3 command. Parameters retries Enter a number of attempts that FTOS tries to locate a RADIUS server. The range is from zero (0) to 100.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series.
Usage Information If the TACACS group is not configured for Authentication, Authorization, and Accounting, then globally configured TACACS servers are used for the purposes. When the TACACS group is removed, the AAA configuration is also removed. Example Dell(conf)#tacacs-server group group1 Dell(conf-tacacs-group)#tacacs-server host 1.1.1.1 key secret Dell(conf-tacacs-group)#tacacs-server host 2.2.2.
• For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a Null interface, enter the keyword null then the Null interface number.
Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4.(0.0) Introduced on the S-Series and Z-Series. Usage Information You can associate a TACACS server group with a VRF. Example Dell(conf)#tacacs-server group group1 Dell(conf-tacacs-group)#tacacs-server host 1.1.1.1 key secret Dell(conf-tacacs-group)#tacacs-server host 2.2.2.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.4.1.0 Added support for IPv6. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Authentication key length increased to 42 characters. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series.
key • 0 is the default and means the key is not encrypted and stored as clear text. • 7 means that the key is encrypted and hidden. Enter a text string, up to 42 characters long, as the clear text password. Leading spaces are ignored. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
• For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Defaults Not configured. Command Modes TACACS SERVER GROUP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4.(0.
• If 802.1X authorization is enabled and all information from the RADIUS server is valid, the port is placed in the specified VLAN after authentication. • If port security is enabled on an 802.1X port with VLAN assignment, the port is placed in the RADIUS server assigned VLAN. • If 802.1X is disabled on the port, it is returned to the configured access VLAN. • When the port is in the Force Authorized, Force Unauthorized, or Shutdown state, it is placed in the configured access VLAN. • If an 802.
Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. dot1x authentication (Configuration) — enables dot1x globally. dot1x auth-fail-vlan Configure an authentication failure VLAN for users and devices that fail 802.1X authentication.
Related Commands dot1x port-control — enables port-control on an interface. dot1x guest-vlan — configures a guest VLAN for non-dot1x devices. show dot1x interface — displays the 802.1X information on an interface. dot1x auth-server Configure the authentication server to RADIUS. Syntax dot1x auth-server radius Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the C-Series, S-Series, and E-Series. 802.1X authentication is enabled when an interface is connected to the switch. If the host fails to respond within a designated amount of time, the authenticator places the port in the guest VLAN.
Usage Information Version Description 8.4.1.0 Introduced on the C-Series and S-Series. To disable MAC authentication bypass on a port, enter the no dot1x mac-auth-bypass command. dot1x max-eap-req Configure the maximum number of times an extensive authentication protocol (EAP) request is transmitted before the session times out. Syntax dot1x max-eap-req number To return to the default, use the no dot1x max-eap-req command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
dot1x reauthentication Enable periodic re-authentication of the client. Syntax dot1x reauthentication [interval seconds] To disable periodic re-authentication, use the no dot1x reauthentication command. Parameters interval seconds (Optional) Enter the keyword interval then the interval time, in seconds, after which re-authentication is initiated. The range is from 1 to 31536000 (1 year). The default is3600 (1 hour).
Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. dot1x server-timeout Configure the amount of time after which exchanges with the server time-out. Syntax dot1x server-timeout seconds To return to the default, use the no dot1x server-timeout command.
Parameters seconds Enter a time-out value in seconds. The range is from 1 to 300, where 300 is implementation dependant. The default is 30. Defaults 30 seconds Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.
Version Description 7.4.1.0 Introduced on the E-Series. show dot1x interface Display the 802.1X information on an interface. Syntax Parameters Defaults Command Modes Command History show dot1x interface interface interface Enter one of the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
Mac-Auth-Bypass Only: Tx Period: Quiet Period: ReAuth Max: Supplicant Timeout: Server Timeout: Re-Auth Interval: Max-EAP-Req: Host Mode: Auth PAE State: Backend State: Dell# Disable 30 seconds 60 seconds 2 30 seconds 30 seconds 3600 seconds 2 SINGLE_HOST Initialize Initialize Dell# show dot1x interface fortyGigE 1/48 802.
NOTE: You must have a license to access the FIPS mode. For more information, contact rsa1 Enter the keyword rsa1 then the key size to generate a SSHv1 RSA host keys. The range is from NOTE: This option is not available in FIPS mode. Defaults Key size 1024; if you enable FIPS mode, the key size is 2048. Command Modes CONFIGURATION Command History This guide is platform-specific.
crypto key zeroize rsa Removes the generated RSA host keys and zeroize the key storage location. Syntax crypto key zeroize rsa Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.5(0.
Usage Information Debug information includes details for key-exchange, authentication, and established session for each connection. ip scp topdir Identify a location for files used in secure copy transfer. Syntax ip scp topdir directory To return to the default setting, use the no ip scp topdir command. Parameters directory Enter a directory name. Defaults The internal flash (flash:) is the default directory. Command Modes CONFIGURATION Command History This guide is platform-specific.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series.
ip ssh hostbased-authentication Enable hostbased-authentication for the SSHv2 server. Syntax ip ssh hostbased-authentication enable To disable hostbased-authentication for SSHv2 server, use the no ip ssh hostbasedauthentication enable command. Parameters enable Enter the keyword enable to enable hostbased-authentication for SSHv2 server. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific.
Parameters 512-869 Enter the key-size number for the server-generated RSA SSHv1 key. The range is from 512 to 869. The default is 768. Defaults Key size 768 Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. With password authentication enabled, you can authenticate using the local, RADIUS, or TACACS+ password fallback order as configured. ip ssh pub-key-file Specify the file used for host-based authentication. Syntax Parameters ip ssh pub-key-file {WORD} WORD Enter the file name for the host-based authentication.
NOTE: For rhostfile and pub-key-file, the administrator must FTP the file to the chassis. Example Dell#conf Dell(conf)# ip ssh pub-key-file flash://knownhosts Dell(conf)# Related Commands show ip ssh client-pub-keys — displays the client-public keys used for the host-based authentication. ip ssh rekey Configures the time rekey-interval or volume rekey-limit threshold at which to re-generate the SSH key during an SSH session.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Enabling RSA authentication allows the user to log in without being prompted for a password. In addition, the OpenSSH compatible SSHv2 RSA public key must be added to the list of authorized keys (ip ssh rsa-authentication my-authorized-keys device://filename command).
mac hmacalgorithm • aes128-ctr • aes192-ctr • aes256-ctr Enter the keyword mac then a space-delimited list of hash message authentication code (HMAC) algorithms supported by the SSH server for keying hashing for the message authentication. The following HMAC algorithms are available: • hmac-sha1 • hmac-sha1-96 • hmac-sha2-256 • hmac-sha2-256-96 When FIPS is enabled, the default HMAC algorithm is hmac-sha1-96.
NOTE: If you enable FIPS mode, you can only select version 2. Defaults • Default listening port is 22. • Default cipher list is 3des-cbc,aes128-cbc,aes192-cbc,aes256-cbc,aes128-ctr,aes192-ctr,aes256-ctr. • When FIPS is enabled, the default is hmac-sha1-96. • When FIPS is not enabled, the default is hmac-md5,hmac-md5-96,hmac-sha1,hmac-sha1-96,hmacsha2-256,hmac-sha2-256-96. • When FIPS is enabled, the default is diffie-hellman-group14-sha1.
ip ssh server vrf Configure an SSH server on either a specific VRF or a management VRF. Syntax NOTE: Some of the parameters in this command require licensing to access. For more information, contact your Dell Networking representative. ip ssh server vrf {management | vrf-name} To disable the SSH server configuration, use the no ip ssh server vrf {management | vrfname} command.
To delete a source interface, use the no ip ssh source-interface command. Parameters interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.4(0.0) Introduced on the S-Series and Z9000.
Version Description 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Usage Information This command is useful if the remote SSH client implements Strict Host Key Checking.
SSH server kex algorithms : diffie-hellman-group-exchange-sha1,diffiehellman-group1-sha1,diffie-hellman-group14-sha1. Password Authentication : enabled. Hostbased Authentication : disabled. RSA Authentication : disabled. Vty Encryption HMAC Remote IP 2 aes128-cbc hmac-md5 10.16.127.141 4 aes128-cbc hmac-md5 10.16.127.141 * 5 aes128-cbc hmac-md5 10.16.127.141 Dell# Related Commands ip ssh server — configures an SSH server. show ip ssh client-pub-keys — displays the client-public keys.
yLPI5eehQTyaldRPHtGyPlcmMbCH +QJkqtyiwDPmH4njyDMYDCXY85vc55ibWsN9qalagklnh2cj2q4nYj5x8+8OOhYeFPaHiygd8U/ FXict61jWs84Co1UTsAgRzDJ9aUSS75TVac= Dell# Related Commands ip ssh pub-key-file — configures the filename for the host-based authentication. show ip ssh rsa-authentication Display the authorized-keys for the RSA authentication. Syntax show ip ssh rsa-authentication {my-authorized-keys} Parameters my-authorized-keys Display the RSA authorized keys.
ssh Open an SSH connection specifying the hostname, username, encryption cipher, HMAC algorithm, port number, and version of the SSH client. Syntax NOTE: Some of the parameters in this command require licensing to access. For more information, contact your Dell Networking representative.
• hmac-sha1-96 : Force ssh to use hmac-sha1-96 HMAC algorithm. • hmac-sha2-256 : Force ssh to use hmac-sha2-256 HMAC algorithm. • hmac-sha2-256-96: Force ssh to use hmac-sha2-256-96 HMAC algorithm. -p port-number (OPTIONAL) Enter the keyword -p then the port number. The range is from 1 to 65535. The default is 22. -v {1 | 2} (OPTIONAL) Enter the keyword -v then the SSH version 1 or 2. The default is the version from the protocol negotiation. Defaults As shown in the Parameters section.
Secure DHCP Commands DHCP as defined by RFC 2131 provides no authentication or security mechanisms. Secure DHCP is a suite of features that protects networks that use dynamic address allocation from spoofing and attacks. clear ip dhcp snooping Clear the DHCP binding table. Syntax clear ip dhcp snooping binding Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific.
Version Description 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series and S-Series. ip dhcp snooping Enable DHCP Snooping globally. Syntax [no] ip dhcp snooping Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific.
Defaults Command Modes Command History ip ip-address Enter the keyword ip then the IP address that the server is leasing. interface type Enter the keyword interface then the type of interface to which the host is connected. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series and S-Series.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series and S-Series.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
Role-Based Access Control Commands With Role-Based Access Control (RBAC), access and authorization is controlled based on a user’s role. Users are granted permissions based on their user roles, not on their individual user ID. User roles are created for job functions and through those roles they acquire the permissions to perform their associated job function. This section describes the syntax and usage of RBAC-specific commands.
Related Commands login authentication, password, radius-server host, tacacs-server host enable Enter EXEC Privilege mode or any other privilege level configured. After entering this command, you may need to enter a password. Syntax enable [level] Parameters level (OPTIONAL) Enter a number for a privilege level of Dell Networking OS. The range is from 0 to 15. Defaults 15 Command Modes EXEC Command History This guide is platform-specific.
Parameters mode Enter one of the following keywords as the mode for which you are controlling access: configure for CONFIGURATION mode exec for EXEC mode interface for INTERFACE modes line for LINE mode route-map for Route-map mode router for Router mode addrole Enter the keyword addrole to add permission to the command. You cannot add or delete rights for the sysadmin role. deleterole Enter the keyword deleterole to remove access to the command. You cannot add or delete rights for the sysadmin role.
Defaults none Command Modes EXEC Privilege Command History Examples • route-map • router Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.
To delete a role name, use the no userrole name command. Note that the reserved role names may not be deleted. Parameters name Enter a text string for the name of the user up to 63 characters. It cannot be one of the system defined roles (sysadmin, secadmin, netadmin, netoperator). inherit existing-rolename Enter the inherit keyword then specify the system defined role to inherit permissions from (sysadmin, secadmin, netadmin, netoperator).
53 Service Provider Bridging Service provider bridging is composed of virtual local area network (VLAN) Stacking, Layer 2 Protocol Tunneling, and Provider Backbone Bridging as described in the Dell Networking OS Configuration Guide Service Provider Bridging chapter. This chapter includes command line information (CLI) for the Dell Networking operating software Layer 2 Protocol Tunneling (L2PT). L2PT enables protocols to tunnel through an 802.1q tunnel. Dell Networking OS supports L2PT on Dell Networking OS.
• For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. in | out | both Enter the keyword in, out, or both to debug incoming interfaces, outgoing interfaces, or both incoming and outgoing interfaces. vlan vlan-id Enter the keyword vlan then the VLAN ID. The range is from 1 to 4094. count value Enter the keyword count then the number of debug outputs. The range is from 1 to 100. Defaults Debug disabled.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guid. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 8.5.1.1 Added support for 802.1X, E-LMI, GMRP, GVRP, LLDP, LACP, MMRP, MVRP, and OAM 802.
Version Description 7.4.1.0 Introduced Usage Information When you enable VLAN-Stacking, no protocol packets are tunneled. Related Command show protocol-tunnel — displays tunneling information for all VLANs. protocol-tunnel enable Enable protocol tunneling globally on the system. Syntax protocol-tunnel enable To disable protocol tunneling, use the no protocol-tunnel enable command. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series, E-Series and E-Series ExaScale. 7.4.1.
54 sFlow The Dell Networking operating software (OS) supports sFlow commands on Dell Networking OS. Dell Networking operating software sFlow monitoring system includes an sFlow Agent and an sFlow Collector. • The sFlow Agent combines the flow samples and interface counters into sFlow datagrams and forwards them to the sFlow Collector. • The sFlow Collector analyses the sFlow Datagrams received from the different devices and produces a network-wide view of traffic flows.
To delete a configured collector, use the no sflow collector {ip-address | ipv6-address} agent-addr {ipv4-address | ipv6-address} [number [max-datagram-size number]] | [max-datagram-size number] [vrf management] command. Parameters sflow collector ipaddress | ipv6address Enter the IP address of the collector in dotted decimal format for IPv4 or x:x:x:x::x format for IPv6.
Usage Information Version Description 6.2.1.1 Introduced on the E-Series. You can configure up to two sFlow collectors (IPv4 or IPv6). If two collectors are configured, traffic samples are sent to both. The sFlow agent address is carried in a field in SFlow packets and is used by the collector to identify the sFlow agent. In sFlow, the agent address is a single invariant IPv4 or IPv6 address used to identify the agent to the collector.
Version Description 7.6.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. Usage Information sFlow is disabled by default. In addition to this command, sFlow needs to be enable on individual interfaces where sFlow sampling is desired. Related Commands sflow enable (Interface) — enables sFlow on interfaces. sflow ingress-enable Enable sFlow ingress on interfaces. Syntax sflow ingress-enable To disable sFlow, use the no sflow ingress enable command. Defaults Disabled.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on S-Series Stacking. 8.1.1.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced on the S Series and Z Series switches. Dell(conf)#sflow max-header-size extended sflow polling-interval (Global) Set the sFlow polling interval at a global level. Syntax sflow polling-interval interval value To return to the default, use the no sflow polling-interval interval command. Parameters interval value Enter the interval value in seconds. The range is from 15 to 86400 seconds. The default is 20 seconds.
sflow polling-interval (Interface) Set the sFlow polling interval at an interface (overrides the global-level setting.) Syntax sflow polling-interval interval value To return to the default, use the no sflow polling-interval interval command. Parameters interval value Enter the interval value in seconds. The range is from 15 to 86400 seconds. The default is the global counter polling interval. Defaults The same value as the current global default counter polling interval.
Defaults 32768 packets Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on S-Series Stacking. 8.1.1.0 Introduced on the E-Series ExaScale. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on S-Series Stacking. 8.1.1.
55 Simple Network Management Protocol (SNMP) and Syslog This chapter contains commands to configure and monitor the simple network management protocol (SNMP) v1/v2/v3 and Syslog. Both features are supported on Dell Networking OS. The chapter contains the following sections: • SNMP Commands • Syslog Commands SNMP Commands The following SNMP commands are available in the Dell Networking OS.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. Example Dell#show snmp engineID Local SNMP engineID: 0000178B02000001E80214A8 Remote Engine ID IP-addr Port 80001F88043132333435 172.31.1.3 5009 80001F88043938373635 172.31.1.
Example Related Commands Dell#show snmp group groupname: v1v2creadg readview : v1v2cdefault notifyview: v1v2cdefault row status: active Dell# security model: v1 writeview: no write view specified context: no context specified snmp-server group — configures an SNMP server group. show snmp user Display the information configured on each SNMP user name. Syntax Command Modes Command History show snmp user • EXEC • EXEC Privilege This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
ipv6 access-listname (Optional) Enter the keyword ipv6 then an IPv6 ACL name (a string up to 16 characters long). security-name name (Optional) Enter the keywords security-name then the security name as defined by the community MIB. access-list-name (Optional) Enter a standard IPv4 access list name (a string up to 16 characters long). Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific.
Example Dell#config Dell(conf)# snmp-server community public ro Dell(conf)# snmp-server community guest ro security-name guestuser Dell(conf)# Example Dell(conf)# ip access-list standard snmp-ro-acl Dell(config-std-nacl)#seq 5 permit host 10.10.10.224 Dell(config-std-nacl)#seq 10 deny any count ! Dell(conf)#snmp-server community guest ro snmp-ro-acl Dell(conf)# Related Commands ip access-list standard — names (or selects) a standard access list to filter based on IP address.
snmp-server enable traps Enable SNMP traps. Syntax snmp-server enable traps [notification-type] [notification-option] To disable traps, use the no snmp-server enable traps [notification-type] [notification-option] command. Parameters notification-type notification-option Enter the type of notification from the following list: • bgp — Notification of changes in the BGP process. • config — Notification of changes to the startup or running configuration. • ecfm — Notification of changes to ECFM.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Added the following two SNMP notification options: syslog-reachable and syslog-unreachable. 9.7(0.0) Introduced on the S6000-ON. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 9.1(0.0) Added support for copy-config and ECMP traps. 8.3.19.0 Introduced on the S4820T. 8.3.11.
remote ip-address Enter the keyword remote followed by the IP address that identifies the copy of the SNMP on the remote device. vrf vrf-name Enter the keyword vrf followed by the name of the VRF that is used to reach the device. NOTE: Use this attribute to specify the VRF that is used by the SNMP engine to reach the device. If no VRF is specified, then the default VRF is used.
snmp-server group Configure a new SNMP group or a table that maps SNMP users to SNMP views.
Defaults As above. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.10.
NOTE: The :: notation specifies successive hexadecimal fields of zero. vrf vrf-name Enter the keyword vrf and then the name of the VRF that the SNMP server uses to connect to the host. NOTE: You can use this attribute to inform the SNMP engine about the vrf instance to be used to reach the corresponding remote host to send Trap or Inform message. If no VRF is specified, then the default VRF is used. traps (OPTIONAL) Enter the keyword traps to send trap notifications to the specified host.
• lacp — Enable LACP state change traps. • isis — Enable ISIS adjacency change traps • pfc — Enable pfc traps • snmp — Enable SNMP trap • stp — Enable 802.1d state change traps • vlt — Enable VLT traps • vrrp — Enable VRRP state change traps • xstp — Enable 802.1s, 802.1w, and PVST+ state change traps The default is all trap types are sent to host. Defaults As above. Command Modes CONFIGURATION Command History This guide is platform-specific.
The snmp-server host command is used with the snmp-server enable command. Use the snmpserver enable command to specify which SNMP notifications are sent globally. For a host to receive most notifications, at least one snmp-server enable command and the snmp-server host command for that host must be enabled.
Version Description E-Series legacy command snmp-server packetsize Set the largest SNMP packet size permitted. Wen the SNMP server is receiving a request or generating a reply, use the snmpserver packetsize global configuration command. Syntax Parameters snmp-server packetsize byte-count byte-count Enter one of the following values 8, 16, 24 or 32. Packet sizes are 8000 bytes, 16000 bytes, 32000 bytes, and 64000 bytes.
• For a port channel interface, enter the keywords port-channel then a number. • For a Null interface, enter the keyword null then the Null interface number. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Defaults The IP address assigned to the management interface is the default. Command Modes CONFIGURATION Command History This guide is platform-specific.
group_name Enter a text string (up to 20 characters long) as the name of the group. The following groups are created for mapping to read/write community/security-names (defaults): • v1v2creadu — maps to a community with ro permissions. • 1v2cwriteu — maps to a community rw permissions. remote ip-address Enter the keywords udp-port then the user datagram protocol (UDP) port number on the remote device. The range is from 0 to 65535. The default is 162.
ipv6 access-listname (Optional) Enter the keyword ipv6 then the IPv6 access list name (a string up to 16 characters long). access-list-name ipv6 access-listname (Optional) Enter both an IPv4 and IPv6 access list name. Defaults As above. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Example Dell#conf Dell(conf)# snmp-server user n3user ngroup remote 172.31.1.3 udp-port 5009 3 auth md5 authpasswd Related Commands show snmp user — displays the information configured on each SNMP user name. snmp-server user (for AES128-CFB Encryption) Specify that AES128-CFB encryption algorithm needs to be used for transmission of SNMP information. The Advanced Encryption Standard (AES) Cipher Feedback (CFB) 128-bit encryption algorithm is in compliance with RFC 3826.
command in Global Configuration mode. You can enable or disable FIPS mode only if SNMPv3 users are not previously set up. Otherwise, you must remove the previously configured users before you change the FIPS mode. Example Dell# snmp-server user privuser v3group v3 encrypted auth md5 9fc53d9d908118b2804fe80e3ba8763d priv aes128 d0452401a8c3ce42804fe80e3ba8763d Related Commands show snmp user — Displays the information configured on each SNMP user name. snmp-server view Configure an SNMPv3 view.
snmp-server vrf Configures an SNMP agent to bind to a specific VRF. Syntax snmp-server vrf vrf-name To undo the SNMP agent configuration, use the no snmp-server vrf vrf-name command. Parameters vrf vrf-name Enter the keyword vrf and then the name of the VRF to associate an SNMP agent with that VRF. Defaults Not Enabled. Command Modes CONFIGURATION Command History This guide is platform-specific.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Usage Information If the interface is expected to flap during normal usage, you could disable this command. Syslog Commands The following commands allow you to configure logging functions on all Dell Networking switches. clear logging Clear the messages in the logging buffer.
clear logging auditlog Clears audit log. Syntax clear logging auditlog Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the S4810, S4820T, S6000, Z9000, and MXL.
default logging console Return the default settings for messages logged to the console. Syntax default logging console Defaults level = 7 or debugging Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Version Description 7.5.1.0 Introduced on the C-Series. E-Series legacy command Related Commands logging monitor — sets the logging monitor parameters. terminal monitor — sends system messages to the terminal/monitor. default logging trap Return to the default settings for logging messages to the Syslog servers. Syntax default logging trap Defaults level = 6 or informational Command Modes CONFIGURATION Command History This guide is platform-specific.
NOTE: The :: notation specifies successive hexadecimal fields of zeros. hostname Enter the name of a host already configured and recognized by the switch. udp Enter the keyword udp to enable transmission of log message over UDP followed by port number. The default port is 514 tcp Enter the keyword tcp to enable transmission of log message over TCP followed by port number. vrf vrf-name (Optional) Enter the keyword vrf and then the name of the VRF to enable the logging process in VRF mode.
logging buffered Enable logging and specify which messages are logged to an internal buffer. By default, all messages are logged to the internal buffer. Syntax logging buffered [level] [size] To return to the default values, use the default logging buffered command. To disable logging stored to an internal buffer, use the no logging buffered command.
logging console Specify which messages are logged to the console. Syntax logging console [level] To return to the default values, use the default logging console command. To disable logging to the console, use the no logging console command. Parameters level (OPTIONAL) Indicate a value from 0 to 7 or enter one of the following parameters: emergencies, alerts, critical, errors, warnings, notifications, informational, or debugging. The default is 7 or debugging.
Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the S4810, S4820T, S6000, Z9000, and MXL. This command is available with or without RBAC enabled.
• lpr (line printer system) • mail (mail system) • news (USENET news) • sys9 (system use) • sys10 (system use) • sys11 (system use) • sys12 (system use) • sys13 (system use) • sys14 (system use) • syslog (Syslog process) • user (user process) • uucp (Unix to Unix copy process) The default is local7. Defaults local7 Command Modes CONFIGURATION Command History This guide is platform-specific.
Parameters level Indicate a value from 0 to 7 or enter one of the following equivalent words: emergencies, alerts, critical, errors, warnings, notifications, informational, or debugging. The default is 4 or warnings. Defaults warnings or 4 Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Usage Information When the number of messages reach the limit you set with the logging history size command, older messages are deleted as newer ones are added to the table.
Version Description 7.5.1.0 Introduced on the C-Series. E-Series legacy command Related Commands default logging monitor — returns the logging monitor parameters to the default setting. logging on Specify that debug or error messages are asynchronously logged to multiple destinations, such as the logging buffer, Syslog server, or terminal lines. Syntax logging on To disable logging to logging buffer, Syslog server and terminal lines, use the no logging on command. Defaults Enabled.
logging source-interface Specify that the IP address of an interface is the source IP address of Syslog packets sent to the Syslog server. Syntax logging source-interface interface To disable this command and return to the default setting, use the no logging source-interface command. Parameters interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
Usage Information Syslog messages contain the IP address of the interface used to egress the router. By configuring the logging source-interface command, the Syslog packets contain the IP address of the interface configured. Related Commands logging — enables logging to the Syslog server. logging synchronous Synchronize unsolicited messages and Dell Networking OS output.
If the message queue limit is reached on a terminal line and messages are discarded, a system message appears on that terminal line. Messages may continue to appear on other terminal lines. Related Commands logging on — enables logging. logging trap Specify which messages are logged to the Syslog server based the message severity. Syntax logging trap [level] To return to the default values, use the default logging trap command. To disable logging, use the no logging trap command.
logging version Displays syslog messages in a RFC 3164 or RFC 5424 format. Syntax logging version {0|1} Defaults 0 Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
%RPM:0:0 %CHMGR-2-LINECARDDOWN - Line card 3 down - IPC timeout Dell# show logging auditlog Displays an audit log. Syntax show logging auditlog Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. This command displays internal software driver information, which may be useful during troubleshooting switch initialization errors, such as a downed Port-Pipe. terminal monitor Configure the Dell Networking OS to display messages on the monitor/terminal.
56 SNMP Traps This chapter lists the traps sent by the Dell Networking operating software. Each trap is listed by the fields Message ID, Trap Type, and Trap Option. Message ID Trap Type Trap Option COLD_START SNMP COLDSTART WARM_START SNMP WARMSTART COPY_CONFIG_COMPLETE SNMP NONE SNMP LINKDOWN SNMP LINKUP SNMP AUTH EGP_NEIGHBOR_LOSS SNMP NONE OSTATE_DOWN SNMP LINKDOWN SNMP LINKUP SNMP NONE SNMP NONE SNMP NONE SNMP NONE %SNMP-5-SNMP_COLD_START: SNMP COLD_START trap sent.
Message ID Trap Type Trap Option SNMP NONE SNMP NONE SNMP NONE NONE NONE ENVMON NONE ENVMON NONE ENVMON NONE CHM_CARD_PROBLEM ENVMON NONE CHM_ALARM_CUTOFF ENVMON NONE CHM_SFM_UP ENVMON NONE CHM_SFM_DOWN ENVMON NONE CHM_RPM_UP ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE %RPM0-P:CP %SNMP-4-RMON_HC_FALLING_THRESHOLD: RMON highcapacity falling threshold alarm from SNMP OID BER_ERR %IFMGR-5-BER_ERR: High Ber detected on interface : %s BER_ERR_CLR %IFMGR-5-BER_ERR_C
Message ID Trap Type Trap Option CHM_SFM_REMOVE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON SUPPLY ENVMON SUPPLY ENVMON SUPPLY ENVMON SUPPLY ENVMON SUPPLY ENVMON SUPPLY ENVMON TEMP ENVMON TEMP ENVMON TEMP ENVMON TEMP ENVMON FAN %TSM-5-SFM_REMOVE: Removed SFM 1 CHM_MAJ_SFM_DOWN %CHMGR-0-MAJOR_SFM: Major alarm: Switch fabric down CHM_MAJ_SFM_DOWN_CLR %CHMGR-5-MAJOR_SFM_CLR: Major alarm cleared: Switch fabric up CHM_MIN_SFM_DOWN %CHMGR-2-MINOR_SFM: MIn
Message ID Trap Type Trap Option ENVMON FAN ENVMON FAN ENVMON FAN ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE For E1200: %CHMGR-2-FAN_TRAY_BAD: Major alarm: fan tray %d is missing or down %CHMGR-2-ALL_FAN_BAD: Major alarm: all fans in fan tray %d are down.
Message ID Trap Type Trap Option ENVMON NONE ENVMON NONE ENVMON NONE PROTO NONE PROTO NONE PROTO NONE PROTO NONE PROTO NONE %MACMGR-5-DETECT_STN_MOVE: Station Move threshold exceeded for Mac %s in vlan %d PORT_TEMP_MAJOR %CHMGR-1-PORT_TEMP_MAJOR: Major Alarm Interface %s shut due to high temperature PORT_TEMP_MINOR %CHMGR-1-PORT_TEMP_MINOR: Minor Alarm Interface %s temperature exceeds threshold PORT_TEMP_MAJOR_CLR %CHMGR-1-PORT_TEMP_MAJOR_CLR: Major Alarm cleared for Interface %s port tem
57 Stacking All commands in this chapter are specific to the Dell Networking operating software. You can use the commands to pre-configure a switch, so that the configuration settings are invoked when the switch is attached to other S-Series units. For information about using the S-Series stacking feature, refer to the “Stacking S-Series Switches” chapter in the Dell Networking OS Configuration Guide. CAUTION: You cannot enable stacking simultaneously with virtual link trunking (VLT).
Usage Information Enabling this command keeps the failed switch in the Failed state. The switch does not reboot until it is manually rebooted. When enabled, it is not displayed in the running-config. When disabled, it is displayed in the running-config. Related Commands show redundancy — displays the current redundancy status. redundancy force-failover stack-unit Force the standby unit in the stack to become the management unit.
Version Description 9.7(0.0) Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.3.1.0 Added the members option. reset stack-unit Reset any designated stack member except the management unit (master unit). Syntax reset stack-unit hard Parameters stack-unit Enter the stack-unit number. The range is from 0 to 11. hard Reset the stack unit if the unit is in a problem state.
5 6 7 8 9 10 11 Related Commands • Member Member Member Member Member Member Member not not not not not not online S4810 present present present present present present S4810 8-3-12-1 64 reload – reboots Dell Networking OS. show redundancy Display the current redundancy configuration (status of automatic reboot configuration on stack management unit). Syntax Command Modes Command History show redundancy • EXEC • EXEC Privilege This guide is platform-specific.
-----------------------------------------------Primary Stack-unit: mgmt-id 0 Auto Data Sync: Full Failover Type: Hot Failover Auto reboot Stack-unit: Disabled Auto failover limit: 3 times in 60 minutes -- Stack-unit Failover Record ------------------------------------------------Failover Count: 0 Last failover timestamp: None Last failover Reason: None Last failover type: None -- Last Data Block Sync Record: -----------------------------------------------stack-unit Config: Start-up Config: Runtime Event Log
Usage Information Example The following describes the show system stack-ports command shown in the following example. Field Description Topology Lists the topology of stack ports connected: Ring, Daisy chain, or Standalone. Interface The unit/port ID of the connected stack port on this unit. Link Speed Link Speed of the stack port (10 or 40) in Gb/s. Admin Status The only currently listed status is Up. Connection The stack port ID to which this unit’s stack port is connected.
0/51 1/49 1/50 2/49 2/51 2/52 Dell# Related Commands 2/49 0/49 2/51 0/51 1/50 • reset stack-unit – resets the designated stack member. • show hardware stack-unit – displays the data plane or management plane input and output statistics of the designated component of the designated stack member. • show system (S-Series and Z-Series) – displays the current status of all stack members or a specific member. stack-unit priority Configure the ability of a switch to become the management unit of a stack.
stack-unit provision Preconfigure a logical stacking ID of a switch that joins the stack. This is an optional command that is executed on the management unit. Syntax Parameters stack-unit [stack-number] provision {S4810|S4820T|S6000|Z9000} stack-unit Enter a stack member identifier of the switch that you want to add to the stack. S4810|S4820T| S6000|Z9000 Enter the model identifier of the switch to be added as a stack member. This identifier is also referred to as the provision type.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.1 Introduced on the S4810. 8.3.12.0 Reset command mode from EXEC to CONFIGURATION.
Usage Information Related Commands Version Description 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. To reboot using the new image, use the upgrade boot system stack-unit command. • reload — reboots Dell Networking OS. • reset stack-unit — resets the designated stack member. • show system (S-Series and Z-Series) — displays the status of all stack members or a specific member.
58 Storm Control The Dell Networking operating software storm control feature allows you to limit or suppress traffic during a traffic storm (Broadcast/Unknown Unicast Rate Limiting or Multicast on the C-Series and S-Series). Storm control is supported on Dell Networking OS. Important Points to Remember • Interface commands can only be applied on physical interfaces (virtual local area networks [VLANs] and link aggregation group [LAG] interfaces are not supported).
• Defaults Command Modes Command History For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. none • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 E-Series Only: Added the percentage decimal value option. 6.5.1.0 Introduced on the E-Series. Broadcast storm control is valid on Layer 2/Layer 3 interfaces only. Layer 2 broadcast traffic is treated as unknown-unicast traffic.
storm-control multicast (Configuration) Configure the packets per second (pps) of multicast traffic allowed into the C-Series and S-Series networks only. Syntax storm-control multicast packets_per_second in To disable storm-control for multicast traffic into the network, use the no storm-control multicast packets_per_second in command. Parameters packets_per_secon d in Enter the packets per second of multicast traffic allowed into the network. The range is from 0 to 33554368.
Command Modes INTERFACE (conf-if-interface-slot/port) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
Usage Information Version Description 6.5.1.0 Introduced on the E-Series. Unknown Unicast Storm-Control is valid for Layer 2 and Layer 2/Layer 3 interfaces. storm-control unknown-unicast (Interface) Configure percentage of unknown-unicast traffic allowed on an interface (ingress only).
Storm Control Version Description 7.5.1.0 Introduced on the C-Series. 7.4.1.0 E-Series Only: Added the percentage decimal value option. 6.5.1.0 Introduced on the E-Series.
59 Spanning Tree Protocol (STP) The commands in this chapter configure and monitor the IEEE 802.1d spanning tree protocol (STP) and are supported on the Dell Networking switch/routing platform. bridge-priority Set the bridge priority of the switch in an IEEE 802.1D spanning tree. Syntax bridge-priority {priority-value | primary | secondary} To return to the default value, use the no bridge-priority command. Parameters priority-value Enter a number as the bridge priority value.
bpdu-destination-mac-address Use the Provider Bridge Group address in Spanning Tree or GVRP PDUs. Syntax bpdu-destination-mac-address [stp | gvrp] provider-bridge-group Parameters xstp Force STP, RSTP, and MSTP to use the Provider Bridge Group address as the destination MAC address in its BPDUs. gvrp Forces GVRP to use the Provider Bridge GVRP Address as the destination MAC address in its PDUs. Defaults The destination MAC address for BPDUs is the Bridge Group Address.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.
Related Commands Version Description 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced protocol spanning-tree — enters SPANNING TREE mode on the switch. disable Disable the spanning tree protocol globally on the switch. Syntax disable To enable Spanning Tree Protocol, use the no disable command. Defaults Enabled (that is, the spanning tree protocol is disabled.) Command Modes SPANNING TREE Command History This guide is platform-specific.
Defaults 15 seconds Command Modes SPANNING TREE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Related Commands Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. forward-delay — changes the wait time before STP transitions to the Forwarding state. max-age — changes the wait time before STP refreshes protocol configuration information.
protocol spanning-tree To enable and configure the spanning tree group, enter SPANNING TREE mode. Syntax protocol spanning-tree stp-id To disable the Spanning Tree group, use the no protocol spanning-tree stp-id command. Parameters stp-id Enter zero (0). Dell Networking OS supports one spanning tree group, group 0. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.
Example Field Description “Designated port...” Displays the designated port ID. Dell#show spann 0 Executing IEEE compatible Spanning Tree Protocol Bridge Identifier has priority 32768, Address 0001.e800.0a56 Configured hello time 2, max age 20, forward delay 15 We are the root of the spanning tree Current root has priority 32768 address 0001.e800.
Usage Information Example (Guard) The following describes the show spanning-tree 0 guard command shown in the example. Field Description Interface Name STP interface. Instance STP 0 instance. Sts Port state: root-inconsistent (INCON Root), forwarding (FWD), listening (LIS), blocking (BLK), or shut down (EDS Shut). Guard Type Type of STP guard configured (Root, Loop, or BPDU guard).
Enter the optional keyword shutdown-on-violation to hardware disable an interface when a BPDU is received and the port is disabled. priority priority Enter keyword priority then a number as the priority. The range is from zero (0) to 15. The default is 8. Defaults cost = depends on the interface type; priority = 8 Command Modes INTERFACE Command History This guide is platform-specific.
• If a BPDU is received from a remote device, BPDU guard places the port in an Err-Disabled Blocking state and no traffic is forwarded on the port. • If no BPDU is received from a remote device, loop guard places the port in a Loop-Inconsistent Blocking state and no traffic is forwarded on the port. To display the type of STP guard (Portfast BPDU, root, or loop guard) enabled on a port, enter the show spanning-tree 0 command.
60 System Time and Date The commands in this chapter configure time values on the system, either using the Dell Networking operating software, or the hardware, or using the network time protocol (NTP). With NTP, the switch can act only as a client to an NTP clock host. For more information, refer to the “Network Time Protocol” section of the Management chapter in the Dell Networking OS Configuration Guide.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
start-month Enter the name of one of the 12 months in English. start-time Enter the time in hours:minutes. For the hour variable, use the 24-hour format; example, 17:15 is 5:15 pm. end-week Enter the one of the following as the week that daylight saving ends: • week-number: enter a number from 1 to 4 as the number of the week to end daylight saving time. • first: enter the keyword first to end daylight saving time in the first week of the month.
clock timezone Configure a timezone for the switch. Syntax clock timezone timezone-name offset To delete a timezone configuration, use the no clock timezone command. Parameters timezone-name Enter the name of the timezone. You cannot use spaces. offset Enter one of the following: • a number from 1 to 23 as the number of hours in addition to universal time coordinated (UTC) for the timezone. • a minus sign (-) then a number from 1 to 23 as the number of hours. Defaults Not configured.
Parameters adjust Enter the keyword adjust to display information on NTP clock adjustments. all Enter the keyword all to display information on all NTP transactions. authentication Enter the keyword authentication to display information on NTP authentication transactions. events Enter the keyword events to display information on NTP events. loopfilter Enter the keyword loopfilter to display information on NTP local clock frequency.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. You also must configure an authentication key for NTP traffic using the ntp authentication-key command.
Usage Information Version Description 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. After configuring the ntp authentication-key command, configure the ntp trusted-key command to complete NTP authentication. Dell Networking OS versions 8.2.1.0 and later use an encryption algorithm to store the authentication key that is different from previous Dell Networking OS versions; beginning in version 8.2.1.
ntp disable Prevent an interface from receiving NTP packets. Syntax ntp disable To re-enable NTP on an interface, use the no ntp disable command. Defaults Disabled (that is, if you configure an NTP host, all interfaces receive NTP packets) Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.4.1.0 Added support for IPv6 multicast addresses. 8.3.7.0 Introduced on the S4810.
Parameters vrf vrf-name (Optional) Enter the keyword vrf and then the name of the VRF to configure a NTP time-serving host corresponding to that VRF. ipv4-address | ipv6address Enter an IPv4 address (A.B.C.D) or IPv6 address (X:X:X:X::X) of NTP server. hostname Enter the hostname of the server. key keyid (OPTIONAL) Enter the keyword key and a number as the NTP peer key. The range is from 1 to 4294967295.
ntp source Specify an interface’s IP address to be included in the NTP packets. Syntax ntp source interface To delete the configuration, use the no ntp source command. Parameters interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 7.6.1.0 Introduced on the S-Series. 7.5.1.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. Example Dell#show clock 11:05:56.949 UTC Thu Oct 25 2001 Dell# Example (Detail) Dell#show clock detail 12:18:10.
Field Description (none) One or more of the following symbols could be displayed: • * means synchronized to this peer. • # means almost synchronized to this peer. • + means the peer was selected for possible synchronization. • - means the peer is a candidate for selection. • ~ means the peer is statically configured. remote Displays the remote IP address of the NTP peer. ref clock Displays the IP address of the remote peer’s reference clock.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.6(0.0) Added support for VRF. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 8.4.1.0 Added IPv6 support. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. show ntp status Display the current NTP status. Syntax show ntp status Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific.
Field Description “frequency is...” Displays the frequency (in ppm), stability (in ppm) and precision (in Hertz) of the clock in this system. “reference time is...” Displays the reference time stamp. “clock offset is...” Displays the system offset to the synchronized peer and the time delay on the path to the NTP root clock. “root dispersion is...” Displays the root and path dispersion. “peer mode is...” State what NTP mode the switch is. This should be Client mode.
61 u-Boot All commands in this chapter are in u-Boot and are supported on the Dell Networking S4810 and 4820T platforms only. To access this mode, press any key when the following line appears on the console during a system boot. Hit any key to stop autoboot: Enter u-Boot immediately, as the => prompt indicates. NOTE: This chapter describes only a few commands available in u-Boot.
+$filesize; cmp.b $loadaddr 0xfff80000 $filesize ethact=eTSEC1 ethaddr=00:01:E8:82:09:B2 serverip=10.11.9.4 primary_boot=f10boot tftp://10.11.9.2/si-S4810-40g secondary_boot=f10boot flash0 default_boot=f10boot tftp://192.168.128.1/FTOS-SC-1.2.0.0E3.bin gatewayip=10.11.192.254 ipaddr=10.11.198.114 netmask=255.255.0.
save Save configurations created in uBoot. Syntax save Command Modes uBoot Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version 8.3.19.0 Introduced on the S4820T. Version 8.3.7.0 Introduced on the S4810.
Command Modes uBoot Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version 8.3.19.0 Introduced on the S4820T. Version 8.3.7.0 Introduced on the S4810.
62 Tunneling Tunneling is supported on Dell Networking OS. ip unnumbered Configure a tunnel interface to operate without a unique IPv4 address and select the interface from which the tunnel borrows its address. Syntax ip unnumbered {interface-type slot/port} To set the tunnel back to default logical address use the no ip unnumbered command. If the tunnel was previously operational, the tunnel interface is operationally down unless you also configure the tunnel IPv6 address.
ipv6 unnumbered Configure a tunnel interface to operate without a unique IPv6 address and select the interface from which the tunnel borrows its address. Syntax ipv6 unnumbered {interface-type interface-number} To set the tunnel back to default logical address use the no ipv6 unnumbered command. If the tunnel was previously operational, the tunnel interface is operationally down unless you also configure the tunnel IPv4 address. Parameters interface-type interface-number Defaults None.
mask (OPTIONAL) Enter a network mask in /prefix format (/x) or A.B.C.D to match a range of remote addresses. The default mask is /32 for IPv4 addresses and /128 for IPv6 addresses, which match only the specified address. Defaults If you do not configure tunnel allow remote , all traffic which is destined to tunnel source address is decapsulated. Command Modes INTERFACE TUNNEL Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.
To establish a logical tunnel to the particular destination address, use the destination address of the outer tunnel header. If you configure a tunnel interface or source address, the tunnel destination must be compatible. tunnel dscp Configure the method to set the DSCP in the outer tunnel header. C9000 Series Syntax tunnel dscp {mapped | value} To use the default tunnel mapping behavior, use the no tunnel dscp value command.
Parameters value Enter a value to set the IPv6 flow label value in the tunnel header. The range is from 0 to 1048575. The default value is 0. Defaults 0 (Mapped original packet flow-label value to tunnel header flow-label value) Command Modes INTERFACE TUNNEL (conf-if-tu) Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.3(0.0) Introduced on the S6000, S4810, S4820T, Z9000.
To disable the tunnel keepalive probes use the no tunnel keepalive command. Parameters ip-address ipv6 address Enter the IPv4 or IPv6 address of the peer to which the keepalive probes will be sent. interval seconds Enter the keyword interval then the interval time, in seconds, after which the restart process to keepalive probe packets. The range is from 5 to 255. The default is 5. count (OPTIONAL) Enter the keyword count to count packets processed by the filter. The range is from 3 to 10.
Parameters ipip Enable tunnel in RFC 2003 mode and encapsulate IPv4 and/or IPv6 datagrams inside an IPv4 tunnel. ipv6 Enable tunnel in RFC 2473 mode and encapsulate IPv4 and/or IPv6 datagrams inside an IPv6 tunnel. ipv6ip Enable tunnel in RFC 4213 mode and encapsulate IPv6 datagrams inside an IPv4 tunnel. decapsulate-any (Optional) Enable tunnel in multipoint receive-only mode. Defaults There is no default tunnel mode.
• anylocal For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Enter the anylocal command to allow the multipoint receive-only tunnel to decapsulate tunnel packets destined to any local ip address. Defaults none Command Modes INTERFACE TUNNEL (conf-if-tu) Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.4(0.0) Added the tunnel source anylocal command. 9.3(0.
63 Uplink Failure Detection (UFD) Uplink failure detection (UFD) provides detection of the loss of upstream connectivity and, if you use this with NIC teaming, automatic recovery from a failed link. clear ufd-disable Re-enable one or more downstream interfaces on the switch/router that are in a UFD-Disabled Error state so that an interface can send and receive traffic.
• uplink-state-group — creates an uplink-state group and enables the tracking of upstream links. debug uplink-state-group Enable debug messages for events related to a specified uplink-state group or all groups. S4810 Syntax debug uplink-state-group [group-id] To turn off debugging event messages, enter the no debug uplink-state-group [group-id] command. Parameters group-id Enables debugging on the specified uplink-state group. The valid group-id values are from 1 to 16.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.4.2.3 Introduced on the S-Series S50.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.4.2.3 Introduced on the S-Series S50. You can assign physical port or port-channel interfaces to an uplink-state group. You can assign an interface to only one uplink-state group. Configure each interface assigned to an uplinkstate group as either an upstream or downstream interface, but not both. You can assign individual member ports of a port channel to the group.
downstream disable links Configure the number of downstream links in the uplink-state group that are disabled if one upstream link in an uplink-state group goes down. Syntax downstream disable links {number |all} To revert to the default setting, use the no downstream disable links command. Parameters number Enter the number of downstream links to be brought down by UFD. The range is from 1 to 1024. all Brings down all downstream links in the group.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 8.3.19.0 Introduced on the S4820T 8.3.12.0 Introduced on the S4810. 8.4.2.
! uplink state track 2 downstream TenGigabitEthernet 1/1,3,5,7-10 upstream FortygigabitEthernet 1/31,42 Related Commands • show uplink-state-group — displays the status information on a specified uplink-state group or all groups. • uplink-state-group — creates an uplink-state group and enables the tracking of upstream links. show uplink-state-group Display status information on a specified uplink-state group or all groups.
Upstream Interfaces : Downstream Interfaces : Uplink State Group : 3 Status: Enabled, Up Upstream Interfaces : Te 1/25(Up) Te 1/28(Up) Downstream Interfaces : Te 5/1(Up) Te 5/1(Up) Te 5/3(Up) Te 5/5(Up) Te 5/6(Up) Uplink State Group : 5 Status: Enabled, Down Upstream Interfaces : Te 1/1(Dwn) Te 1/3(Dwn) Te 1/5(Dwn) Downstream Interfaces : Te 5/2(Dis) Te 5/4(Dis) Te 5/11(Dis) Te 5/12(Dis) Te 5/13(Dis) Te 5/14(Dis) Te 5/15(Dis) Uplink State Group : 6 Status: Enabled, Up Upstream Interfaces : Downstream Interf
Usage Information After you enter the command, to assign upstream and downstream interfaces to the group, enter UplinkState-Group Configuration mode. An uplink-state group is considered to be operationally up if at least one upstream interface in the group is in the Link-Up state. An uplink-state group is considered to be operationally down if no upstream interfaces in the group are in the Link-Up state. No uplink-state tracking is performed when a group is disabled or in an operationally down state.
Usage Information Version Description 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.4.2.3 Introduced on the S-Series S50. You can assign physical port or port-channel interfaces to an uplink-state group. You can assign an interface to only one uplink-state group.
64 VLAN Stacking With the virtual local area network (VLAN)-stacking feature (also called stackable VLANs and QinQ), you can “stack” VLANs into one tunnel and switch them through the network transparently. The Dell Networking operating software supports this feature on Dell Networking OS. For more information about basic VLAN commands, refer to the Virtual LAN (VLAN) Commands section in the Layer 2 chapter.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the C-Series and S-Series. dei honor Honor the incoming DEI value by mapping it to an Dell Networking OS drop precedence. Enter the command once for 0 and once for 1. Syntax Parameters dei honor {0 | 1} {green | red | yellow} 0|1 Enter the bit value you want to map to a color.
dei mark Set the DEI value on egress according to the color currently assigned to the packet. S4810 Syntax dei mark {green | yellow} {0 | 1} Parameters 0|1 Enter the bit value you want to map to a color. green | red | yellow Choose a color: • Green: High priority packets that are the least preferred to be dropped. • Yellow: Lower priority packets that are treated as best-effort. Defaults All the packets on egress are marked with DEI 0.
• For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. Defaults Not configured. Command Modes CONF-IF-VLAN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.
Usage Information WARNING: The following message displays to confirm the command: All non-default configurations on the related member ports ports () will be removed. Do you want to continue (y/n)? If you enter “y”, all non-default configurations on any member ports of the current stack group is removed when the unit is rebooted. vlan-stack access Specify a Layer 2 port or port channel as an access port to the stackable VLAN network.
To disable the Stackable VLAN feature on a VLAN, use the no vlan-stack compatible command. Defaults Not configured. Command Modes CONF-IF-VLAN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
vlan-stack dot1p-mapping Map C-Tag dot1p values to a S-Tag dot1p value. You can separate the C-Tag values by commas and dashed ranges are permitted. Dynamic mode CoS overrides any Layer 2 QoS configuration in case of conflicts. Syntax vlan-stack dot1p-mapping c-tag-dot1p values sp-tag-dot1p value Parameters c-tag-dot1p value Enter the keyword c-tag-dot1p then the customer dot1p value that is mapped to a service provider do1p value. The range is from 0 to 7.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the E-Series ExaScale. C-Series and S-Series accept both bytes of the 2-byte S-Tag TPID. 8.2.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the C-Series and S-Series.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the E-Series ExaScale. C-Series and S-Series accept both bytes of the 2-byte S-Tag TPID. 7.8.1.0 Functionality augmented for C-Series and S-Series to enable multi-purpose use of the port. 7.7.1.0 Functionality augmented for E-Series to enable multi-purpose use of the port. 7.6.1.
! interface Vlan 20 no ip address tagged TenGigabitEthernet 1/42 shutdown Dell(conf-if-vl-20)#do show vlan Codes: * - Default VLAN, G - GVRP VLANs Q: U - Untagged, T - Tagged x - Dot1x untagged, X - Dot1x tagged G - GVRP tagged, M - Vlan-stack NUM Status Description * 1 Inactive 20 Active 100 Active Dell(conf-if-vl-20)# Example 2 Q Ports T Te 1/42 M Te 1/42 Dell(config)#vlan-stack protocol-type 88A8 Dell(config)#interface TenGigabitethernet 3/10 Dell(conf-if-te-3/10)#no shutdown Dell(conf-if-te-3/10)#swit
65 Virtual Routing and Forwarding (VRF) Virtual Routing and Forwarding (VRF) allows multiple instances of a routing table to co-exist on the same router at the same time. ip vrf Creates a customer VRF. Syntax ip vrf {vrf-name | management} [vrf_id] To delete a customer VRF, use the no ip vrf {vrf-name | management} [vrf_id] command. Parameters vrf-name Enter the name of the VRF that you want to create. management Use this keyword when you want to create the management VRF.
ip http vrf Configures an HTTP client with a VRF that is used to connect to the HTTP server. S4810 Syntax ip http vrf {management | vrf-name} To undo the HTTP client configuration, use the ip http vrf command. Parameters management Enter the keyword management for configuring the management VRF that uses an HTTP client. vrf-name Enter the name of the VRF for configuring a nondefault that uses an HTTP client.
Usage Information Version Description 9.5(0.0) Introduced on the Z9500. 9.4.(0.0) Introduced on the S-Series. Use this command to specify a descriptive name for a VRF. ip vrf forwarding Enables you to attach an interface to a VRF. Syntax ip vrf forwarding {vrf-name | management} To delete an interface associated with a configured VRF, use the no ip vrf forwarding {vrf-name | management} command. Parameters vrf-name Enter name of the VRF that you want to associate the interface to.
ip vrf red 4 description "Red Network" Dell(conf-vrf)# Dell(conf-if-te-1/45)#int te 7/46 Dell(conf-if-te-1/46)#no shut Dell(conf-if-te-1/46)#ip vrf forwarding red Dell(conf-if-te-1/46)#ip add 100.1.1.1/24 Dell(conf-if-te-1/46)# Dell(conf-if-te-1/46)# Dell(conf-if-te-1/46)# Dell(conf-if-te-1/46)#show config ! interface TenGigabitEthernet 1/46 ip vrf forwarding red ip address 100.1.1.1/24 no shutdown Dell(conf-if-te-1/46)# ip route-export Enables route leaking between VRFs.
Only Active routes are eligible for leaking. For example, if one VRF has two routes corresponding to BGP and OSPF, in which the BGP route is not active, the OSPF route takes precedence over BGP. Even though the Target VRF has specified filtering options to match BGP, the BGP route is not leaked as that route is not active in the Source VRF. Related Commands ip route-import – imports routes from another VRF.
ipv6 route-export Enables route leaking between VRFs. Exports or shares IPv6 routes corresponding to one VRF with other non-default VRFs. Syntax Parameters Defaults ipv6 route-export tag [route-map-name] route-export Enter the keyword route-export to leak or share routes between VRFs. tag Enter a tag (ASN number) as the export route target to expose routes to other VRFs. This tag acts as an identifier for exported routes.
Parameters route-import Enter the keyword route-import to import IPv6 routes into the VRF. tag Enter a tag (ASN number) to specify an import route target for importing routes from another VRF. To import leaked routes from another VRF, you must use the same ASN number that is specified as the export route target at the source VRF. route-map-name Enter the name of the route-map to filter the imported routes. NOTE: You must use the route-map attribute while importing routes from the global RTM.
Usage Information You can specify the matching criteria only after defining a route-map. Before using this command, you must enter the route map mode using the route-map route-map-name command. The match criteria that you specify is associated with the route-map that you define. The export-target and import-target support only the match protocol and match prefix-list options. Other options that are configured in the route-maps are ignored.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.4.(0.0) Introduced on the S-Series and Z9000. Use this command to associate a management port with a management VRF.
Usage Information If the maximum route limit is not specified for a VRF, then it has unlimited space that extends to the maximum number of entries allowed for the system. This command is not applicable to the default and management VRFs. show ip vrf Displays information corresponding to the VRFs that are configured in the system. Syntax Parameters Command Modes show ip [vrf vrf-name] vrf vrf-name Enter the keyword vrf and then the name of the VRF to display information corresponding to that VRF..
test1 1 Te 0/14,16-17 show run vrf Displays configuration information corresponding to all the VRFs in the system. Syntax show run vrf vrf-name Parameters Command Modes Command History vrf vrf-name • EXEC • EXEC Privilege Enter the keyword vrf and then the name of the VRF.. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
66 VLT Proxy Gateway The Virtual link trucking (VLT) proxy gateway feature allows a VLT domain to locally terminate and route L3 packets that are destined to a Layer 3 (L3) end point in another VLT domain. Enable the VLT proxy gateway using the link layer discover protocol (LLDP) method or the static configuration. For more information, refer to Dell Networking OS Command Line Reference Guide. proxy-gateway lldp Enables the proxy-gateway feature using LLDP protocol.
Command History Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S4810, S4820T, S6000, Z9000. Usage Information When proxy-gateway static configuration is added, the setting is saved in the Layer 2 module. When you remove the static proxy gateway configuration, each proxy-gateway static mac configured is deleted from the Layer 2 module.
peer-domain-link port-channel exclude-vlan Configure the VLT port channel, which is connected to remote VLT domain for Proxy Gateway and configure the VLANs that needs to be excluded from VLT Proxy Gateway. S4810 Syntax Parameters [no] peer-domain-link port-channel interface-identifier exclude-vlan vlanrange port-channel Configure the proxy-gateway interface port-channel. Port channel range is from 1 to 128. vlan-range Enter the VLAN IDs in which proxy gateway is not needed.
Command History Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Removed the default value on the S-Series and Z-Series. 9.4(0.0) Introduced on the S4810, S4820T, S6000, Z9000, and MXL Switch. Usage Information When a VLT peer goes down, the local VLT node must stop sending its peer’s MAC address. If this timeout is configured, the local VLT node will send its peer's MAC address, till the timer expires. By default this timer value is infinity.
static Command Modes Display details about the static VLT proxy gateway configuration EXEC EXEC Privilege Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000.
67 Virtual Link Trunking (VLT) Virtual link trunking (VLT) allows physical links between two chassis to appear as a single virtual link to the network core. VLT eliminates the requirement for Spanning Tree protocols by allowing link aggregation group (LAG) terminations on two separate distribution or core switches, and by supporting a loop-free topology.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.2(0.2) Added support for IPv6. 9.0.2.
Version Description 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. Example VLT ARP Statistics ---------------ARP Tunnel Pkts sent:0 ARP Tunnel Pkts Rcvd:0 ARP-sync Pkts Sent:0 ARP-sync Pkts Rcvd:0 ARP Reg Request sent:19 ARP Reg Request rcvd:10 Related Commands show vlt statistics — displays statistics on VLT operations.
Related Commands • after a VLT device is reloaded. • if the Peer VLT device was up at the time the VLTi link failed to the time when it was restored. show vlt statistics — displays statistics on VLT operations. delay-restore abort-threshold Increase the Boot Up timer to some value (>60 seconds). Syntax delay-restore abort-threshold To remove use the no delay-restore abort-threshold command. Defaults 60 seconds Command Modes VLT DOMAIN Command History This guide is platform-specific.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Added port-channel parameter on the S4810. 8.3.8.0 Introduced on the S4810.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.2(0.2) Introduced on the Z9000, S4810, and S4820T. 9.0.2.0 Introduced on the S6000. peer-link port-channel Configure the specified port channel as the chassis interconnect trunk between VLT peers in the domain.
peer-routing Enable L3 VLT peer-routing. This command is applicable for both IPV6/ IPV4. Syntax peer-routing To disable L3 VLT peer-routing, use the no peer-routing command. Defaults Disabled. Command Modes VLT DOMAIN (conf-vlt-domain) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Usage Information Version Description 9.2(0.2) Introduced on the Z9000, S4810, and S4820T. 9.0.2.0 Introduced on the S6000. When the timer expires, the software checks to see if the VLT peer is now available. If the VLT peer is not available, peer-routing is disabled on that peer. primary-priority Assign the priority for master election among VLT peers.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.8.0 Introduced on the S4810.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.8.0 Introduced on the S4810. Dell_VLTpeer1# show vlt backup-link VLT Backup Link ----------------Destination: Peer HeartBeat status: HeartBeat Timer Interval: HeartBeat Timeout: UDP Port: HeartBeat Messages Sent: HeartBeat Messages Received: 10.11.200.
Version Description 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. Usage Information If you do not add a parameter such as arp or mac, the output displays all of the counters.
Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.8.
(*, 225.1.1.2) Dell# VLAN 15 te 1/5 show vlt mismatch Display mismatches in VLT parameters. Syntax show vlt mismatch Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. Version The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.
PB for stp Enabled Disabled Vlan-type-config ---------------Codes:: P - Primary, C - Community, I - Isolated, N - Normal vlan, M Vlan-stack Vlan-ID ------- Local ----- 100 Peer ---- N M Port-type-config ---------------Codes:: p - PVLAN Promiscuous port, h - PVLAN Host port, t - PVLAN Trunk port, mt - Vlan-stack trunk port, mu - Vlan-stack access port, n Normal port Vlt Lag ------128 Local ----mt Peer ---mu Vlan-stack protocol-type -----------------------Local ----0x4100 Peer ---0x8100 VLT-VLAN
Example Version Description 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.8.0 Introduced on the S4810.
Related Commands Example Version Description 9.2(0.2) Added parameters multicast and ndp 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Added support in the output for ARP, MAC, and IGMP snooping. 8.3.8.0 Introduced on the S4810. clear vlt statistics — clears the statistics on VLT operations. NOTE: The following example shows the statistics for all of the VLT parameters.
NDP NA VLT Tunnel Pkts Rcvd:46 NDP NA Non-VLT Tunnel Pkts sent:0 NDP NA Non-VLT Tunnel Pkts Rcvd:0 Ndp-sync Pkts Sent:144 Ndp-sync Pkts Rcvd:105 Ndp Reg Request sent:25 Ndp Reg Request rcvd:24 show vlt statistics igmp-snoop Displays the informational packets and IGMP control PDUs that are exchanged between VLT peer nodes. Syntax show vlt statistics igmp-snoop Default Not configured. Command Modes EXEC Command History This guide is platform-specific.
Parameters mac-address Enter the system MAC address for the VLT domain. Defaults Not configured. Command Modes VLT DOMAIN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.5(0.1) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator.
Usage Information Version Description 9.5(0.1) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.8.0 Introduced on the S4810. When you create a VLT domain on a switch, Dell Networking OS automatically assigns a unique unit ID (0 or 1) to each peer switch. The unit IDs are used for internal system operations.
Related Commands show vlt — uses the show vlt brief command to display the delay-restore value. vlt-peer-lag port-channel Associate the port channel to the corresponding port channel in the VLT peer for the VLT connection to an attached device. Syntax Parameters vlt-peer-lag port-channel id-number id-number Enter the respective vlt port-channel number of the peer device. The range is from 1 to 128. Defaults Not configured.
Usage Information If you add an ICL or VLTi link as a member of a primary VLAN, the ICL becomes a part of the primary VLAN and its associated secondary VLANs, similar to the behavior for normal trunk ports. VLAN symmetry is not validated if you associate an ICL to a PVLAN. Similarly, if you dissociate an ICL from a PVLAN, although the PVLAN symmetry exists, ICL is removed from that PVLAN in such a case. The ICL Status field denotes the type of the VLAN port of the VLTi link configured in a PVLAN.
68 Virtual Router Redundancy Protocol (VRRP) Virtual router redundancy protocol (VRRP) is supported by the Dell Networking operating system on Dell Networking OS. IPv4 VRRP Commands The following are IPv4 VRRP commands. advertise-interval Set the time interval between VRRP advertisements. Syntax advertise-interval {seconds | centisecs centisecs } To return to the default settings, use the no advertise-interval command. Parameters seconds Enter the number of seconds. The range is from 1 to 255.
Usage Information Dell Networking recommends keeping the default setting for this command. If you do change the time interval between VRRP advertisements on one router, change it on all routers. authentication-type Enable authentication of VRRP data exchanges. Syntax authentication-type simple [encryption-type] password To delete an authentication type and password, use the no authentication-type command. Parameters simple Enter the keyword simple to specify simple authentication.
Parameters vrrp-id (OPTIONAL) Enter the number of the VRRP group ID to clear the group’s counters. The range is from 1 to 255. ipv6 (OPTIONAL) Enter the keyword ipv6 to clear counters from the IPv6 VRRP group. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, see the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
• For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a VLAN interface, enter the keyword vlan then the VLAN ID. The VLAN ID range is from 1 to 4094. interface Enter the keyword interface to enable debugging of interface state changes. ipv6 Enter the keyword ipv6 to enable debugging for IPv6.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. disable Disable a VRRP group. Syntax disable To re-enable a disabled VRRP group, use the no disable command. Command Modes VRRP Command History This guide is platform-specific.
To return to the default value, use the no hold-time command. Parameters seconds Enter the number of seconds. The range is from 0 to 65535. The default is zero (0) seconds. centisecs centisecs Enter the keyword centisecs then the number of centisecs in units of 25 centisecs . The range is from 0 to 65525 in units of 25 centisecs. Defaults zero (0) seconds or or (0) centiseconds Command Modes VRRP Command History This guide is platform-specific.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. priority Specify a VRRP priority value for the VRRP group. The VRRP protocol uses this value during the MASTER election process.
If you set the priority command to 255 and the virtual-address is not equal to the interface’s primary IP address, an error message appears. show config View the non-default VRRP configuration. Syntax show config [verbose] Parameters verbose (OPTIONAL) Enter the keyword verbose to view all VRRP group configuration information, including defaults. Command Modes VRRP Command History This guide is platform-specific.
Command Modes Command History • For Port Channel interface types, enter the keywords port-channel then the number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a VLAN interface, enter the keyword vlan then the VLAN ID. The VLAN ID range is from 1 to 4094. ipv6 (OPTIONAL) Enter the keyword ipv6 to view only VRRP IPv6 groups.
Item Description • NA/IF (the interface is not available). • MASTER (the interface associated with the MASTER router). • BACKUP (the interface associated with the BACKUP router). Master addr Displays the IP address of the MASTER router. Virtual addr(s) Displays the virtual IP addresses of the VRRP routers associated with the interface.
Item Description Tracking states.. This line is displayed if the track command is configured on an interface. Below this line, the following information on the tracked interface is displayed: • Dn or Up states whether the interface is down or up. • The interface type slot/port information. Example Dell>show vrrp -----------------TenGigabitEthernet 1/3, VRID: 1, Net: 10.1.1.253 State: Master, Priority: 105, Master: 10.1.1.
Parameters interface priority-cost Defaults priority cost = 10 Command Modes VRRP Command History Usage Information (OPTIONAL) Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For Port Channel interface types, enter the keywords port-channel then a number.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series.
Usage Information Related Command Version Description 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.8.0 Introduced on the S4810. This command applies to a single interface. When used with the vrrp delay reload CLI, the later timer rules the VRRP enabling. For example, if vrrp delay reload is 600 and the vrrp delay minimum is 300: • When the system reloads, VRRP waits 600 seconds (10 minutes) to bring up VRRP on all interfaces that are up and configured for VRRP.
Save the configuration and reload the system for the delay timers to take effect. Related Command vrrp delay minimum — sets the delay time for VRRP initialization after a line card reboot. vrrp-group Assign a VRRP ID to an interface. You can configure up to 12 VRRP groups per interface. Syntax Parameters vrrp-group vrrp-id vrrp-id Enter a number as the group ID. The range is from 1 to 255. Defaults Not configured. Command Modes INTERFACE Command History This guide is platform-specific.
both Enter the both keyword for in-service migration from VRRP version 2 to VRRP version 3. Defaults 2 Command Modes VRRP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.
• priority • show config • virtual-address clear counters vrrp ipv6 Clear the counters recorded for IPv6 VRRP groups. Syntax Parameters clear counters vrrp ipv6 [vrid | vrf vrf-name] vrid (OPTIONAL) Enter the number of an IPv6 VRRP group. The range is from 1 to 255. vrf vrf-name (OPTIONAL) Enter the name of a VRF instance (32 characters maximum) to clear the counters of all IPv6 VRRP groups in the specified VRF. Command Modes EXEC Privilege Command History This guide is platform-specific.
state Enter the keyword state to enable debugging of VRRP state changes timer Enter the keyword timer to enable debugging of the VRRP timer. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 8.
Usage Information Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.2(1.0) Introduced on the Z9500. 8.3.19.0 Introduced on the S4820T. 8.3.10.0 Introduced on the S4810. 8.3.2.0 Introduced on the E-Series TeraScale. The following describes the show vrrp ipv6 command shown in the following example. Line Beginning with Description GigabitEthernet... Displays the Interface, the VRRP group ID, and the network address.
Line Beginning with Description • Example Cost to be subtracted from the VRRP group priority if the state of the tracked interface/object goes DOWN.
microcode is loaded and VRRP group 10 is configured in VRF 2, the VRID used for the VRRP group is (16 x 10) + 2, or 162. This VRID value is used in the lowest byte of the virtual MAC address of the VRRP group and is also used for VRF routing. NOTE: Configure the same VRID on neighboring routers (Dell Networking or non-Dell Networking) in the same VRRP group in order for all routers to interoperate. Related Commands virtual-address — assigns up to 12 virtual IP addresses per VRRP group.