Reference Guide
show interfaces transceiver
Display the physical status and operational status of an installed transceiver. The output also displays the transceiver’s
serial number.
C-Series, E-Series, S-Series, Z-Series
Syntax
show interfaces [gigabitethernet slot/port | tengigabitethernet
slot/port | fortyGigE slot/port] transceiver
Parameters
gigabitethernet For a 10/100/1000 interface, enter the keyword gigabitethernet
followed by the slot/port information.
tengigabitetherne
t
For a 10G interface, enter the keyword tengigabitethernet
followed by the slot/port information.
fortyGigE For a 40G interface, enter the keyword fortyGigE followed by the
slot/port information.
Command Modes
• EXEC
• EXEC Privilege
Command History
Version 8.3.11.1 Introduced on the Z9000.
Version 8.5.1.0 Added support for 4-port 40G line cards on ExaScale.
Version 8.1.1.0 Introduced on the E-Series ExaScale.
Version 7.8.1.0 Output augmented with diagnostic data for pluggable media.
Version 7.7.1.0 Removed three fields in the output: Vendor Name, Vendor OUI, and
Vendor PN.
Version 7.6.1.0 Introduced on the C-Series and S-Series.
Version 6.5.4.0 Introduced on the E-Series.
Usage
Information
The following describes the show interfaces transceiver command shown in the
Example below.
Line Description
Rx Power
measurement type
Output depends on the vendor, typically either “Average” or “OMA”
(Receiver optical modulation amplitude).
Temp High Alarm
threshold
Factory-defined setting, typically in Centigrade. Value differs
between SFPs and SFP+.
Voltage High Alarm
threshold
Displays the interface index number used by SNMP to identify the
interface.
Bias High Alarm
threshold
Factory-defined setting. Value can differ between SFP and SFP+.
818