Reference Guide
NOTE: If a range has VLAN, physical, port-channel, and SONET interfaces, only commands
related to physical interfaces can be bulk configured. To configure commands specific to
VLAN, port-channel, or SONET, only those respective interfaces should be configured in a
particular range.
Example (Single
Range)
This example shows a single range bulk configuration.
FTOS(config)# interface range gigabitethernet 5/1 - 23
FTOS(config-if-range)# no shutdown
FTOS(config-if-range)#
Example (Multiple
Range)
This example shows how to use commas to add different interface types to the range enabling
all Gigabit Ethernet interfaces in the range 5/1 to 5/23 and both Ten Gigabit Ethernet interfaces
1/1 and 1/2.
FTOS(config-if)# interface range gigabitethernet5/1-23,
tengigabitethernet1/1-2
FTOS(config-if-range)# no shutdown
FTOS(config-if-range)#
Example (Multiple
Range)
This example shows how to use commas to add SONET, VLAN, and port-channel interfaces to
the range.
FTOS(config-if)# interface range gigabitethernet5/1-23,
tengigabitethernet1/1–2,
Vlan 2–100, Port 1–25
FTOS(config-if-range)# no shutdown
FTOS(config-if-range)#
Related
Commands
interface port-channel – configures a port channel group.
interface vlan – configures a VLAN interface.
show config (from INTERFACE RANGE mode) – shows the bulk configuration interfaces.
show range – shows the bulk configuration ranges.
interface range macro (define) – defines a macro for an interface-range.
interface range macro (define)
Defines a macro for an interface range and then saves the macro in the running configuration.
C-Series, E-Series, S-Series, Z-Series
Syntax
define interface range macro name interface , interface , ...
Parameters
name
Enter up to 16 characters for the macro name.
interface,
interface,...
Enter the keywords interface range and one of the interfaces
— slot/port, port-channel, or VLAN number. Select the range of
interfaces for bulk configuration. You can enter up to six comma-
separated ranges. Spaces are not required between the commas.
Comma-separated ranges can include VLANs, port-channels, and
physical interfaces.
Slot/Port information must contain a space before and after the dash.
For example, interface range gigabitethernet 0/1 -
783