Reference Guide

Example (rpm)
FTOS#redundancy force-failover rpm
Peer RPM's SW version is different but HA compatible.
Failover can be done by warm or hitless upgrade.
All linecards will be reset during warm upgrade.
Specify hitless upgrade or warm upgrade [confirm hitless/
warm]:hitless
Proceed with warm upgrade [confirm yes/no]:
Example (sfm)
FTOS#redundancy force-failover sfm 0
%TSM-6-SFM_FAILOVER: Standby switch to SFM 8
Standby switch to SFM 0
FTOS#
redundancy primary
Set an RPM as the primary RPM.
C-Series, E-Series, S4810
Syntax
redundancy primary [rpm0 | rpm1]
To delete a configuration, use the no redundancy primary command.
Parameters
rpm0 Enter the keyword rpm0 to set the RPM in slot R0 as the primary
RPM.
rpm1 Enter the keyword rpm1 to set the RPM in slot R1 as the primary
RPM.
Default The RPM in slot R0 is the Primary RPM.
Command Modes CONFIGURATION
Command History
Version 8.3.12.0 Introduced on the S4810.
Version 8.1.1.0 Introduced on the E-Series ExaScale.
Version 7.5.1.0 Introduced on the C-Series.
Version 7.6.1.0 Introduced on the E-Series.
739