Reference Guide

Parameters
count
number
Enter the number of times the RPMs can automatically failover within
the period defined in the period parameter. The range is 2 to 10. The
default is 3.
period
minutes
Enter a duration in which to allow a number of automatic failovers
(limited to the number defined in the count parameter). The range is 5
to 9000 minutes. The default is 60 minutes.
Default
Count: 3
Period: 60 minutes
Command Modes CONFIGURATION
Command History
Version 8.3.12.0 Introduced on the S4810.
Version 8.1.1.0 Introduced on the E-Series ExaScale.
Version 7.5.1.0 Introduced on the C-Series.
Version 7.6.1.0 Introduced on the E-Series
Usage
Information
If you disable auto failover, enter the redundancy auto-failover-limit (without any
parameters) to set auto failover to the default parameters (Count 3, Period 60 minutes). Use the
show redundancy command to view the redundancy status.
When you change one or both of the optional parameters, FTOS checks that the interval
between auto failovers is more than five (5) minutes. If the interval is less, FTOS returns a
configuration error message.
redundancy disable-auto-reboot
Prevent the system from auto-rebooting the failed module.
C-Series, E-Series, S4810
Syntax
redundancy disable-auto-reboot [rpm| card number | all]
To return to the default, use the no redundancy disable-auto-reboot rpm
command.
Parameters
rpm Enter the keyword rpm to disable auto-reboot of the failed RPM.
Default Disabled (that is, the failed module is automatically rebooted).
Command Modes CONFIGURATION
Command History
Version 8.3.12.0 Introduced on the S4810.
737