Reference Guide
Related
Commands
show patch – displays the system patches loaded with the in-service modular hot
fix command.
process restartable
Enable a process to be restarted. Restartability is subject to a maximum restart limit. This limit is defined as a configured
number of restarts within a configured amount of time. On the software exception that exceeds the limit, the system
reloads (for systems with a single RPM) or fails over (for systems with dual RPMs).
E-Series, S4810
Syntax
process restartable [process] [count number] [period minutes]
Parameters
process
Configure a process to be restartable.
count
number
Enter the number of times a process can restart within the configured
period. The range is 1 to 3. The default is 3.
period
minutes
Enter the amount of time within which the process can restart count
times. The range is 1 to 60 minutes. The default is 60 minutes.
Default By default, a process can be restarted a maximum of three times within one hour. On the
exception that exceeds this limit, the system reloads or fails over.
Command Modes CONFIGURATION
Command History
Version 8.3.12.0 Introduced on the S4810.
Version 8.4.1.0 Introduced on the E-Series.
Related
Commands
show processes restartable
redundancy auto-failover-limit
Specify an auto-failover limit for RPMs. When a non-recoverable fatal error is detected, an automatic RPM failover
occurs. This command does not affect user-initiated (manual) failovers.
C-Series, E-Series, S4810
Syntax
redundancy auto-failover-limit [count number [period minutes] |
period minutes]]
To disable the auto-failover limit control, use the no redundancy auto-failover-
limit command.
736