Reference Guide

120.10.10.2 300 40 47 34 0 0 00:37:10 0
FTOS#
show running-config bgp
Use this feature to display the current BGP configuration.
C-Series, E-Series, S-Series, Z-Series, S4810
Syntax
show running-config bgp
Defaults none
Command Modes EXEC Privilege
Command History
Version 8.3.11.1 Introduced on the Z9000.
Version 8.3.7.0 Introduced on the S4810.
Version 7.8.1.0 Introduced on the S-Series.
Version 7.7.1.0 Introduced on the C-Series.
Version 7.6.1.0 Introduced on the E-Series.
timers bgp
Adjust the BGP Keep Alive and Hold Time timers.
C-Series, E-Series, S-Series, Z-Series, S4810
Syntax
timers bgp keepalive holdtime
To return to the default, use the no timers bgp command.
Parameters
keepalive
Enter a number for the time interval, in seconds, between keepalive
messages sent to the neighbor routers. The range is 1 to 65535. The
default is 60 seconds.
holdtime
Enter a number for the time interval, in seconds, between the last
keepalive message and declaring the router dead. The range is 3 to
65535. The default is 180 seconds.
Defaults none
Command Modes EXEC Privilege
Command History
Version 8.3.11.1 Introduced on the Z9000.
Version 8.3.7.0 Introduced on the S4810.
Version 7.8.1.0 Introduced on the S-Series.
Version 7.7.1.0 Introduced on the C-Series.
446