Reference Guide

log (OPTIONAL, E-Series only) Enter the keyword log to log the packets.
monitor (OPTIONAL) Enter the keyword monitor when the rule is describing
the traffic that you want to monitor and the ACL in which you are
creating the rule is applied to the monitored interface.
NOTE: For more information, refer to the Flow-based Monitoring
section in the Port Monitoring chapter of the
FTOS Configuration
Guide
.
Defaults Not configured.
Command Modes CONFIGURATION-MAC ACCESS LIST-EXTENDED
Command History
Version 8.3.11.1 Introduced on the Z9000.
Version 8.1.1.0 Introduced on the E-Series ExaScale.
Version 7.6.1.0 Introduced on the S-Series.
Version 7.5.1.0 Introduced on the C-Series.
Version 7.4.1.0 Added the monitor option.
pre-Version
6.1.1.0
Introduced on the E-Series.
Usage
Information
When you use the log option, the CP processor logs details about the packets that match.
Depending on how many packets match the log entry and at what rate, the CP may become
busy as it has to log these packets’ details.
NOTE: When ACL logging and byte counters are configured simultaneously, byte counters
may display an incorrect value. Configure packet counters with logging instead.
Related
Commands
deny – configures a MAC ACL filter to drop packets.
seq – configure a MAC ACL filter with a specified sequence number.
seq
Configure a filter with a specific sequence number.
C-Series, E-Series, S-Series, Z-Series
Syntax
seq sequence-number {deny | permit} {any | host mac-address |
mac-source-address mac-source-address-mask} {any | host mac-
address | mac-destination-address mac-destination-address-mask}
[ethertype operator] [count [byte]] [log] [monitor]
To delete a filter, use the no seq sequence-number command.
Parameters
sequence-
number
Enter a number as the filter sequence number. The range is zero (0) to
65535.
301