Reference Guide
log (OPTIONAL, E-Series only) Enter the keyword log to enter ACL
matches in the log.
dscp (OPTIONAL) Enter the keyword dcsp to match to the IP DCSCP
values.
order (OPTIONAL) Enter the keyword order to specify the QoS priority for
the ACL entry. The range is 0 to 254 (where 0 is the highest priority
and 254 is the lowest; lower-order numbers have a higher priority). If
you do not use the keyword order, the ACLs have the lowest order
by default (255).
monitor (OPTIONAL) Enter the keyword monitor when the rule is describing
the traffic that you want to monitor and the ACL in which you are
creating the rule is applied to the monitored interface. For more
information, refer to the “Flow-based Monitoring” section in the Port
Monitoring chapter of the
FTOS Configuration Guide
.
fragments Enter the keyword fragments to use ACLs to control packet
fragments.
Defaults Not configured.
Command Modes CONFIGURATION-EXTENDED-ACCESS-LIST
Command History
Version 8.3.11.1 Introduced on the Z9000.
Version 8.3.7.0 Introduced on the S4810.
Version 8.3.1.0 Add the DSCP value for ACL matching.
Version 8.2.1.0 Allows ACL control of fragmented packets for IP (Layer 3) ACLs.
Version 8.1.1.0 Introduced on the E-Series ExaScale.
Version 7.6.1.0 Introduced on the S-Series.
Version 7.5.1.0 Introduced on the C-Series.
Version 7.4.1.0 Added support for the noncontiguous mask and added the monitor
option.
Version 6.5.1.0 Expanded to include the optional QoS order priority for the ACL
entry.
Usage
Information
The order option is relevant in the context of the Policy QoS feature only. For more
information, refer to the Quality of Service chapter of the
FTOS Configuration Guide
.
When you use the log option, the CP processor logs detail the packets that match. Depending
on how many packets match the log entry and at what rate, the CP may become busy as it has
to log these packets’ details.
The monitor option is relevant in the context of flow-based monitoring only. For more
information, refer to the Port Monitoring chapter.
The C-Series and S-Series cannot count both packets and bytes, when you enter the count
byte options, only bytes are incremented.
253