Reference Guide
When you use the log option, the CP processor logs details about the packets that match.
Depending on how many packets match the log entry and at what rate, the CP may become
busy as it has to log these packets’ details.
The monitor option is relevant in the context of flow-based monitoring only. For more
information, refer to
Port Monitoring
The C-Series and S-Series cannot count both packets and bytes; when you enter the count
byte options, only bytes are incremented.
NOTE: When ACL logging and byte counters are configured simultaneously, byte counters
may display an incorrect value. Configure packet counters with logging instead.
Related
Commands
deny – Assigns a IP ACL filter to deny IP packets.
ip access-list standard – creates a standard ACL.
resequence access-list
Re-assign sequence numbers to entries of an existing access-list.
C-Series, E-Series, S-Series, Z-Series
Syntax resequence access-list {ipv4 | ipv6 | mac} {
access-list-name StartingSeqNum Step-to-
Increment
}
Parameters
ipv4 | ipv6 | mac Enter the keyword ipv4or mac to identify the access list type to
resequence.
access-list-name
Enter the name of a configured IP access list.
StartingSeqNum
Enter the starting sequence number to resequence. The range is 0 to
4294967290.
Step-to-
Increment
Enter the step to increment the sequence number. The range is 1 to
4294967290.
Defaults none
Command Modes
• EXEC
• EXEC Privilege
Command History
Version 8.3.11.1 Introduced on the Z9000.
Version 8.2.1.0 Introduced on the E-Series ExaScale (IPv6).
Version 8.1.1.0 Introduced on the E-Series ExaScale (IPv4).
Version 7.8.1.0 Increased the name string to accept up to 140 characters. Prior to
7.8.1.0, names were up to 16 characters long.
Version 7.6.1.0 Introduced on the S-Series.
Version 7.5.1.0 Introduced on the C-Series.
248