Reference Guide

E-Series Original command.
Usage
Information
show rpm
output Field
Description
Status Displays the RPM’s status.
Next Boot Displays whether the RPM is to be brought online at the next system
reload.
Card Type Displays the RPM catalog number.
Hardware Rev Displays the E-Series chipset hardware revision level: 1.0 (non-
Jumbo); 1.5 (Jumbo-enabled); 2.0 (or above is TeraScale).
Num Ports Displays the number of active ports.
Up Time Displays the number of hours and minutes since the RPM’s last
reboot.
Last Restart States the reason for the last RPM reboot.
C-Series possible values:
“normal power-cycle” (reset power-cycle command)
“reset by master” (peer RPM reset by master RPM)
“over temperature shutdown”
“power supply failed”
E-Series possible values:
“normal power-cycle” (insufficient power, normal power
cycle)
“reset by user” (automatic failover, software reload of both
RPMs, or master RPM resetting peer)
“force-failover” (redundancy force-failover
command)
FTOS Version Displays the operating software version.
Jumbo Capable Displays a Yes or No indicating if the RPM is capable of sending and
receiving Jumbo frames.
This field does not indicate if the chassis is in Jumbo mode; for that
determination, use the show chassis brief command.
CP Boot Flash Displays the two possible Boot Flash versions for the control
processor. The [Booted] keyword next to the version states which
version was used at system boot.
RP1 Boot Flash Displays the two possible Boot Flash versions for the Routing
Processor 1. The [Booted] keyword next to the version states which
version was used at system boot.
185