Reference Guide

<cr>
S50V_7.7#show inventory media
Slot Port Type Media Serial Number F10Qualified
---------------------------------------------------
0 49 Media not present or accessible
0 50 XFP 10GBASE-SR C707XS0MD Yes
0 45 Media not present or accessible
0 46 Media not present or accessible
0 47 Media not present or accessible
0 48 Media not present or accessible
Example (Z9000)
ct-z9000-2#show inventory
System Type : Z9000
System Mode : 1.0
Software Version : 8.3.11.3b
Unit Type Serial Number Part Number Rev Piece
Part ID
Ver Service Tag
-------------------------------------------------------------
* 0 Z9000-01-40GE-AC Z8FX113100314 7520052401 E
MY-08R4VK-75412-1BA-0474 A00 ABC1234
0 Z9000-PWR-AC N/A N/A N/A N/A
N/A N/A
0 Z9000-FAN Z5FX112500170 7520051702 A
MY-08R4VK-75412-1BA-0474 A00 ABC1234
0 Z9000-FAN Z5FX113300293 7520051702 A N/A
N/A N/A
0 Z9000-FAN Z5FX113300160 7520051702 A
MY-08R4VK-75412-1BA-0474 A00 ABC1234
0 Z9000-FAN Z5FX113300136 7520051702 A
MY-08R4VK-75412-1BA-0474 A00 ABC1234
* - Management Unit
Related
Commands
show interfaces – displays the interface configuration.
show interfaces transceiver – displays the physical status and operational status of an
installed transceiver. The output also displays the transceiver’s serial number.
show linecard
Display the line card(s) status.
C-Series, E-Series
Syntax
show linecard [number [brief] | all]
Parameters
number
(OPTIONAL) Enter a slot number to view information on the line card
in that slot. For the C-Series, the range is 0 to 7. For the E-Series, the
ange is 0 to 13 on the E1200, 0 to 6 on the E600, and 0 to 5 on the E300.
162