Reference Guide

-------------------------------------------
Unit TrayStatus Fan0 Fan1 Fan2 Fan3 Fan4 Fan5
0 up up up up up up up
-- Power Supplies --
Unit Bay Status Type
--------------------------------------------
0 0 up AC
0 1 absent
-- Unit Environment Status --
Unit Status Temp Voltage
--------------------------------------------
0* online 50C ok
* Management Unit
-- Fan Status --
Unit Status Speed Fan1 Fan2 Fan3 Fan4 Fan5 Fan6 Serial Num
Version
---------------------------------------------
1 up high up up up up up up 1234 1
Example (fan)
FTOS#show environment fan
-- Fan Status --
---------------------------------------------
Unit TrayStatus Fan0 Fan1 Fan2 Fan3 Fan4 Fan5
0 up up up up up up up
Example (pem)
FTOS#show environment pem
-- Power Supplies --
Unit Bay Status Type
---------------------------------------------
0 0 up AC
0 1 absent
Example (stack-
unit)
FTOS#show environment stack-unit 0
-- Unit Environment Status --
Unit Status Temp Voltage
--------------------------------------------
0* online 49C ok
* Management Unit
show inventory (C-Series and E-Series)
Display the chassis type, components (including media), and FTOS version including hardware identification numbers
and configured protocols.
C-Series, E-Series
Syntax
show inventory [media slot]
Parameters
media
slot
(OPTIONAL) Enter the keyword media followed by the slot number.
For the C-Series, the range is 0-7. For the E-Series, the range is 0 to 13
on the E1200, 0 to 6 on the E600/E600i, and 0 to 5 on the E300.
158