Reference Guide

6 Member not present
7 Member not present
8 Member not present
9 Member not present
10 Member not present
11 Member not present
Related
Commands
reload – reboots FTOS.
upgrade system stack-unit (S-Series stack member) – resets the designated S-Series
stack member.
show redundancy
Display the current redundancy configuration (status of automatic reboot configuration on stack management unit).
S-Series
Syntax
show redundancy
Command Modes
EXEC
EXEC Privilege
Command History
Version 7.7.1.0 Introduced on the S-Series.
Example
FTOS#show redundancy
FTOS#show redundancy
-- SSeries Redundancy Configuration --
------------------------------------------------
Auto reboot : Enabled
-- Stack-unit Status --
------------------------------------------------
Mgmt ID: 0
Stack-unit ID: 0
Stack-unit Redundancy Role: Primary
Stack-unit State: Active
Stack-unit SW Version: 7.7.1.0
Link to Peer: Up
-- PEER Stack-unit Status --
------------------------------------------------
Stack-unit State: Standby
Peer stack-unit ID: 1
Stack-unit SW Version: 7.7.1.0
-- Stack-unit Redundancy Configuration --
------------------------------------------------
Primary Stack-unit: mgmt-id 0
Auto Data Sync: Full
Failover Type: Hot Failover
1543