Reference Guide
• uucp (Unix to Unix copy process)
The default is local7.
Defaults local7
Command Modes CONFIGURATION
Command History
Version 8.3.11.1 Introduced on the Z9000.
Version 8.3.7.0 Introduced on the S4810.
Version 7.6.1.0 Introduced on the S-Series.
Version 7.5.1.0 Introduced on the C-Series.
E-Series legacy
command
Related
Commands
logging – enables logging to a Syslog server.
logging on – enables logging.
logging history
Specify which messages are logged to the history table of the switch and the SNMP network management station (if
configured).
C-Series, E-Series, S-Series, Z-Series
Syntax
logging history level
To return to the default values, use the no logging history command.
Parameters
level
Indicate a value from 0 to 7 or enter one of the following equivalent
words: emergencies, alerts, critical, errors,
warnings, notifications, informational, or
debugging. The default is 4 or warnings.
Defaults warnings or 4
Command Modes CONFIGURATION
Command History
Version 8.3.11.1 Introduced on the Z9000.
Version 8.3.7.0 Introduced on the S4810.
Version 7.6.1.0 Introduced on the S-Series.
Version 7.5.1.0 Introduced on the C-Series.
E-Series legacy
command
1526