Reference Guide
snmp-server view
Configure an SNMPv3 view.
C-Series, E-Series, S-Series, S4810, Z-Series
Syntax
snmp-server view view-name oid-tree {included | excluded}
To remove an SNMPv3 view, use the no snmp-server view view-name oid-tree
{included | excluded} command.
Parameters
view-name
Enter the name of the view (not to exceed 20 characters).
oid-tree
Enter the OID sub tree for the view (not to exceed 20 characters).
included (OPTIONAL) Enter the keyword included to include the MIB family
in the view.
excluded (OPTIONAL) Enter the keyword excluded to exclude the MIB family
in the view.
Defaults none
Command Modes CONFIGURATION
Command History
Version 8.3.11.1 Introduced on the Z9000.
Version 8.3.7.0 Introduced on the S4810.
Version 7.6.1.0 Introduced on the S-Series.
Version 7.5.1.0 Introduced on the C-Series.
E-Series legacy
command
Usage
Information
The oid-tree variable is a full sub-tree starting from 1.3.6 and can not specify the name of a
sub-tree or a MIB. The following Example configures a view named
rview
that allows access to
all objects under 1.3.6.1.
Example
FTOS# conf
FTOS#(conf) snmp-server view rview 1.3.6.1 included
Related
Commands
show running-config snmp – displays the SNMP running configuration.
snmp trap link-status
Enable the interface to send SNMP link traps, which indicate whether the interface is up or down.
C-Series, E-Series, S-Series, Z-Series
Syntax
snmp trap link-status
To disable sending link trap messages, use the no snmp trap link-status command.
1519