Reference Guide
enable xfp-power-updates
Enable 10–gigabit small form-factor pluggable (XFP) power updates for SNMP.
C-Series, E-Series, S-Series
Syntax
enable xfp-power-updates interval seconds
Parameters
interval
seconds
Enter the keyword interval followed by the polling interval in
seconds. Range: 120 to 6000 seconds. Default: 300 seconds (5
minutes).
Defaults Disabled
Command Modes CONFIGURATION
Command History
Version 8.3.11.4 Deprecated command for Z9000 only. Replaced by the enable
optic-info-update interval command to update
information on temperature and power monitoring in the SNMP MIB.
Version 8.3.10.0 Deprecated command for the S4810 only. Replaced by the enable
optic-info-update interval command to update
information on temperature and power monitoring in the SNMP MIB.
Version 8.1.1.0 Introduced on the E-Series ExaScale.
Version 7.6.1.0 Introduced on the S-Series.
Version 7.5.1.0 Introduced on the C-Series and E-Series.
Usage
Information
The chassis MIB contains the entry chSysXfpRecvPower in the chSysPortTable
table. Periodically, IFA polls the XFP power for each of the ports and sends the values to IFM
where it is cached.
Use this command to enable polling and to configure the polling frequency.
end
Return to EXEC Privilege mode from other command modes (for example, CONFIGURATION or ROUTER OSPF modes).
C-Series, E-Series, S-Series, Z-Series
Syntax
end
Command Modes
• CONFIGURATION
• SPANNING TREE
• MULTIPLE SPANNING TREE