Reference Guide

Table Of Contents
To remove this filter, you have two choices:
Use the no seq sequence-number command if you know the filter’s sequence
number.
Use the no deny {any | mac-source-address mac-source-
address-mask
} command.
Parameters
any Enter the keyword any to specify that all routes are subject to the
filter.
mac-source-
address
Enter a MAC address in nn:nn:nn:nn:nn:nn format.
mac-source-
address-mask
(OPTIONAL) Specify which bits in the MAC address must match. If no
mask is specified, a mask of 00:00:00:00:00:00 is applied (in other
words, the filter allows only MAC addresses that match).
count (OPTIONAL) Enter the keyword count to count packets processed
by the filter.
byte (OPTIONAL) Enter the keyword byte to count bytes processed by
the filter.
log (OPTIONAL, E-Series only) Enter the keyword log to log the packets.
monitor (OPTIONAL) Enter the keyword monitor when the rule is describing
the traffic that you want to monitor and the ACL in which you are
creating the rule is applied to the monitored interface. For more
information, refer to the “Flow-based Monitoring” section in the Port
Monitoring chapter of the
FTOS Configuration Guide
.
Defaults Not enabled.
Command Modes CONFIGURATION-MAC ACCESS LIST-STANDARD
Command History
This guide is platform-specific. For command information about other platforms, refer to the
relevant
FTOS Command Line Reference Guide
.
The following is a list of the FTOS version history for this command.
Version 8.3.19.0 Introduced on the S4820T.
Version 8.3.11.1 Introduced on the Z9000.
Version 8.3.7.0 Introduced on the S4810.
Version 8.1.1.0 Introduced on the E-Series ExaScale.
Version 7.6.1.0 Introduced on the S-Series.
Version 7.5.1.0 Introduced on the C-Series.
Version 7.4.1.0 Added the monitor option.
Usage
Information
When you use the log option, the CP processor logs detail the packets that match. Depending
on how many packets match the log entry and at what rate, the CP may become busy as it has
to log these packets’ details.
221