Users Guide
10 Member not present
11 Member not present
-- Power Supplies --
Unit Bay Status Type FanSpeed(rpm)
---------------------------------------------------------------------------
0 0 down UNKNOWN 0
0 1 up AC 14000
-- Fan Status --
Unit Bay TrayStatus Fan0 Speed Fan1 Speed
------------------------------------------------------------------------------------
0 0 up up 13466 up 13466
0 1 up up 13653 up 13466
Speed in RPM
The following example shows the diag command (standalone unit).
Dell#diag stack-unit 1
Warning - diagnostic execution will cause multiple link flaps on the peer side - advisable
to shut directly connected ports
Proceed with Diags [confirm yes/no]: yes
Dell#Jan 16 02:22:46: %S4810:0 %DIAGAGT-6-DA_DIAG_STARTED: Starting diags on stack unit 1
00:06:47 : Approximate time to complete the Diags ... 13 Mins
The following example shows the diag command (stack member).
[output from master unit]
Dell#diag stack-unit 2
Warning - the stack unit will be pulled out of the stack for diagnostic execution
Proceed with Diags [confirm yes/no]: yes
Warning - diagnostic execution will cause multiple link flaps on the peer side - advisable
to shut directly connected ports
Proceed with Diags [confirm yes/no]: yes
Dell#00:03:13: %S25P:2 %DIAGAGT-6-DA_DIAG_STARTED: Starting diags on stack unit 2
00:03:13 : Approximate time to complete these Diags ... 6 Min
00:03:13 : Diagnostic test results will be stored on stack unit 2 file: flash:/
TestReport-SU-2.txt
Dell#00:03:35: %STKUNIT1-M:CP %CHMGR-2-STACKUNIT_DOWN: Stack unit 2 down - card removed
00:08:50: %STKUNIT1-M:CP %CHMGR-5-STACKUNITDETECTED: Stack unit 2 present
00:09:00: %STKUNIT1-M:CP %CHMGR-5-CHECKIN: Checkin from Stack unit 2 (type S25P, 28 ports)
00:09:00: %S25P:2 %CHMGR-0-PS_UP: Power supply 0 in unit 2 is up
00:09:00: %STKUNIT1-M:CP %CHMGR-5-STACKUNITUP: Stack unit 2 is up
[output from the console of the unit in which diagnostics are performed]
Dell(stack-member-2)#
Diagnostic test results are stored on file: flash:/TestReport-SU-2.txt
Diags completed... Rebooting the system now!!!
The following example shows the show file flash:\\ command (standalone member).
Dell#show file flash://TestReport-SU-0.txt
*******************************S-Series Diagnostics***********************
Board : S4810 Dell Inc.
Stack Unit Board Serial Number : HADL112220111
CPU Version : MPC8536E, Version: 1.1
CPLD REVISION : 0x7
CPLD BOARD TYPE : 0x1
Diag image based on build : 9-4(0-89)
Stack Unit Board temperature : 50 Degree C
Stack Unit Number : 1
**************************Stack Unit EEPROM INFO**************************
982
Debugging and Diagnostics