Reference Guide

396 | High Availability
www.dell.com | support.dell.com
linecard 4 invalid 6.5.1.8
linecard 5 is not present.
Note: [b] : booted [n] : next boot
Upgrade cache boot image(4.7.5.427) for all cards [yes/no]: yes
cache boot image downloading in progress...
!!!!!!!!!!!!!!!!!!!!!
cache boot upgrade in progress. Please do NOT power off the card.
Note: Updating Flash Table of Contents...
Erasing TOC area...
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Upgrade result :
================
All cache boot image upgraded to 4.7.5.427
FTOS#
View your cache boot configuration using the command show boot system all, as shown in the example
below.
FTOS#show boot system all
Current system image information in the system:
=============================================
Type Boot Type A B
----------------------------------------------------------------
CP DOWNLOAD BOOT 4.7.5.427 invalid
RP1 DOWNLOAD BOOT 4.7.5.427 invalid
RP2 DOWNLOAD BOOT 4.7.5.427 invalid
linecard 0 DOWNLOAD BOOT 4.7.5.427 invalid
linecard 1 is not present.
linecard 2 is not present.
linecard 3 is not present.
linecard 4 DOWNLOAD BOOT 4.7.5.427 6.5.1.8
linecard 5 is not present.
FTOS#
If you attempt to cache a system image that does not support the cache boot feature, Message 20 appears.
Verify that the system is configured to boot with the selected cache boot image using the command
show
bootvar
as shown in the example below.
FTOS#copy running-config startup-config
File with same name already exist.
Proceed to copy the file [confirm yes/no]: yes
!
10496 bytes successfully copied
1d6h32m: %RPM0-P:CP %FILEMGR-5-FILESAVED: Copied running-config to startup-config in flash by
default
R4_E300#show bootvar
PRIMARY IMAGE FILE = system://4.7.5.427
Message 20 System Image does not Support Cache Boot Error
%% Error: Given image is not cache boot aware image.