Users Guide

Usage Information When you insert or remove a secondary RPM with logical SFM, the system must add or remove the
backplane links to the switch fabric trunk. To avoid trac disruption, use this command when you insert the
secondary RPM. When you execute this command, the logical SFM on the standby RPM is immediately
taken oine and the SFM state is set as “standby”.
NOTE: This command could aect trac when taking the secondary SFM oine.
Example
Dell# show sfm all
Switch Fabric State: up
-- Switch Fabric Modules --
Slot Status
--------------------------------------
0 active
1 active
Dell# configure
Dell(conf)# redundancy sfm standby
Taking secondary SFM offline...
!
Dell(conf)# do show sfm all
Switch Fabric State: up
-- Switch Fabric Modules --
Slot Status
-----------------------------------------
0 active
1 standby
Dell(conf)# no redundancy sfm
Taking secondary SFM online...
!
10Dell(conf)# do show sfm all
Switch Fabric State: up
-- Switch Fabric Modules --
Slot Status
-------------------------------------------
0 active
1 active
redundancy synchronize
Manually synchronize data once between the Master and Stand-by stack units.
S4810
Syntax
redundancy synchronize [full]
Parameters
full Enter the keyword full to synchronize all data.
Default Not congured.
Command Modes EXEC Privilege
High Availability (HA)
655